ABAP Select data from SAP table VIGW_R_FLRAZUF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VIGW_R_FLRAZUF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VIGW_R_FLRAZUF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VIGW_R_FLRAZUF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VIGW_R_FLRAZUF TYPE STANDARD TABLE OF VIGW_R_FLRAZUF,
      WA_VIGW_R_FLRAZUF TYPE VIGW_R_FLRAZUF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VIGW_R_FLRAZUF> TYPE VIGW_R_FLRAZUF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VIGW_R_FLRAZUF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VIGW_R_FLRAZUF
  INTO TABLE IT_VIGW_R_FLRAZUF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VIGW_R_FLRAZUF
*  INTO TABLE @DATA(IT_VIGW_R_FLRAZUF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VIGW_R_FLRAZUF INDEX 1 INTO DATA(WA_VIGW_R_FLRAZUF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VIGW_R_FLRAZUF ASSIGNING <VIGW_R_FLRAZUF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VIGW_R_FLRAZUF>-MANDT = 1.
<VIGW_R_FLRAZUF>-INTRENO = 1.
<VIGW_R_FLRAZUF>-VERSION = 1.
<VIGW_R_FLRAZUF>-INTRENO2 = 1.
<VIGW_R_FLRAZUF>-BUKRS = 1.
ENDLOOP.

LOOP AT IT_VIGW_R_FLRAZUF INTO WA_VIGW_R_FLRAZUF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VIGW_R_FLRAZUF-SWENR, sy-vline,
WA_VIGW_R_FLRAZUF-SGENR, sy-vline,
WA_VIGW_R_FLRAZUF-SGEBT, sy-vline,
WA_VIGW_R_FLRAZUF-FLID, sy-vline,
WA_VIGW_R_FLRAZUF-OBJNR, sy-vline,
WA_VIGW_R_FLRAZUF-IMKEY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VIGW_R_FLRAZUF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VIGW_R_FLRAZUF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VIGW_R_FLRAZUF INTO WA_VIGW_R_FLRAZUF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SWENR, internal->external for field SWENR CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_VIGW_R_FLRAZUF-SWENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIGW_R_FLRAZUF-SWENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SGENR, internal->external for field SGENR CALL FUNCTION 'CONVERSION_EXIT_SGENR_OUTPUT' EXPORTING input = WA_VIGW_R_FLRAZUF-SGENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIGW_R_FLRAZUF-SGENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit IMKEY, internal->external for field IMKEY CALL FUNCTION 'CONVERSION_EXIT_IMKEY_OUTPUT' EXPORTING input = WA_VIGW_R_FLRAZUF-IMKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIGW_R_FLRAZUF-IMKEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TFEINHT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VIGW_R_FLRAZUF-TFEINHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIGW_R_FLRAZUF-TFEINHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RHEINHT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VIGW_R_FLRAZUF-RHEINHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIGW_R_FLRAZUF-RHEINHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field REINHT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VIGW_R_FLRAZUF-REINHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIGW_R_FLRAZUF-REINHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VIGW_R_FLRAZUF-FEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIGW_R_FLRAZUF-FEINH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VIGW_R_FLRAZUF_STR,
MANDT TYPE STRING,
INTRENO TYPE STRING,
VERSION TYPE STRING,
INTRENO2 TYPE STRING,
BUKRS TYPE STRING,
SWENR TYPE STRING,
SGENR TYPE STRING,
SGEBT TYPE STRING,
FLID TYPE STRING,
OBJNR TYPE STRING,
IMKEY TYPE STRING,
JLOESCH TYPE STRING,
FLAA TYPE STRING,
DTRAGFKT TYPE STRING,
TFEINHT TYPE STRING,
DRAUMHOE TYPE STRING,
RHEINHT TYPE STRING,
UMBRAUM TYPE STRING,
REINHT TYPE STRING,
RAAA TYPE STRING,
FLAG TYPE STRING,
FEINH TYPE STRING,
FLKGR TYPE STRING,
FLAGTXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_VIGW_R_FLRAZUF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VIGW_R_FLRAZUF_STR-MANDT sy-vline
WA_VIGW_R_FLRAZUF_STR-INTRENO sy-vline
WA_VIGW_R_FLRAZUF_STR-VERSION sy-vline
WA_VIGW_R_FLRAZUF_STR-INTRENO2 sy-vline
WA_VIGW_R_FLRAZUF_STR-BUKRS sy-vline
WA_VIGW_R_FLRAZUF_STR-SWENR sy-vline
WA_VIGW_R_FLRAZUF_STR-SGENR sy-vline
WA_VIGW_R_FLRAZUF_STR-SGEBT sy-vline
WA_VIGW_R_FLRAZUF_STR-FLID sy-vline
WA_VIGW_R_FLRAZUF_STR-OBJNR sy-vline
WA_VIGW_R_FLRAZUF_STR-IMKEY sy-vline
WA_VIGW_R_FLRAZUF_STR-JLOESCH sy-vline
WA_VIGW_R_FLRAZUF_STR-FLAA sy-vline
WA_VIGW_R_FLRAZUF_STR-DTRAGFKT sy-vline
WA_VIGW_R_FLRAZUF_STR-TFEINHT sy-vline
WA_VIGW_R_FLRAZUF_STR-DRAUMHOE sy-vline
WA_VIGW_R_FLRAZUF_STR-RHEINHT sy-vline
WA_VIGW_R_FLRAZUF_STR-UMBRAUM sy-vline
WA_VIGW_R_FLRAZUF_STR-REINHT sy-vline
WA_VIGW_R_FLRAZUF_STR-RAAA sy-vline
WA_VIGW_R_FLRAZUF_STR-FLAG sy-vline
WA_VIGW_R_FLRAZUF_STR-FEINH sy-vline
WA_VIGW_R_FLRAZUF_STR-FLKGR sy-vline
WA_VIGW_R_FLRAZUF_STR-FLAGTXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.