ABAP Select data from SAP table VIBDOBJASS_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VIBDOBJASS_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VIBDOBJASS_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VIBDOBJASS_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VIBDOBJASS_D TYPE STANDARD TABLE OF VIBDOBJASS_D,
      WA_VIBDOBJASS_D TYPE VIBDOBJASS_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VIBDOBJASS_D> TYPE VIBDOBJASS_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VIBDOBJASS_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VIBDOBJASS_D
  INTO TABLE IT_VIBDOBJASS_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VIBDOBJASS_D
*  INTO TABLE @DATA(IT_VIBDOBJASS_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VIBDOBJASS_D INDEX 1 INTO DATA(WA_VIBDOBJASS_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VIBDOBJASS_D ASSIGNING <VIBDOBJASS_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VIBDOBJASS_D>-MANDT = 1.
<VIBDOBJASS_D>-RESTATUSOBJECTSOURCE = 1.
<VIBDOBJASS_D>-REOBJECTASSIGNMENTTYPE = 1.
<VIBDOBJASS_D>-RESTATUSOBJECTTARGET = 1.
<VIBDOBJASS_D>-VALIDITYSTARTENDDATEVALUE = 1.
ENDLOOP.

LOOP AT IT_VIBDOBJASS_D INTO WA_VIBDOBJASS_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VIBDOBJASS_D-INTERNALREALESTATENUMBER, sy-vline,
WA_VIBDOBJASS_D-DRAFTUUID, sy-vline,
WA_VIBDOBJASS_D-RESTATUSOBJECTTARGETFOREDIT, sy-vline,
WA_VIBDOBJASS_D-REIDENTIFICATION, sy-vline,
WA_VIBDOBJASS_D-PARENTDRAFTUUID, sy-vline,
WA_VIBDOBJASS_D-VALIDITYSTARTDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VIBDOBJASS_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VIBDOBJASS_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VIBDOBJASS_D INTO WA_VIBDOBJASS_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VIBDOBJASS_D_STR,
MANDT TYPE STRING,
RESTATUSOBJECTSOURCE TYPE STRING,
REOBJECTASSIGNMENTTYPE TYPE STRING,
RESTATUSOBJECTTARGET TYPE STRING,
VALIDITYSTARTENDDATEVALUE TYPE STRING,
INTERNALREALESTATENUMBER TYPE STRING,
DRAFTUUID TYPE STRING,
RESTATUSOBJECTTARGETFOREDIT TYPE STRING,
REIDENTIFICATION TYPE STRING,
PARENTDRAFTUUID TYPE STRING,
VALIDITYSTARTDATE TYPE STRING,
VALIDITYENDDATE TYPE STRING,
REENTRYVALIDITY TYPE STRING,
REENTRYVALIDITYCRITICALITY TYPE STRING,
REOBJECTTYPETARGET TYPE STRING,
REONLYINFOASSGMT TYPE STRING,
REOBJECTPOSSESSIONSTARTDATE TYPE STRING,
REOBJECTPOSSESSIONENDDATE TYPE STRING,
REGROUPNUMBER TYPE STRING,
REOBJECTGROUPNAME TYPE STRING,
INTERNALREALESTATENUMBERTARGET TYPE STRING,
RECONTRACTSUBJECTNUMBER TYPE STRING,
RECONTRACTSUBJECTDESCRIPTION TYPE STRING,
RECONTRACTSUBJECTCLASS TYPE STRING,
RECONTRACTSUBJECTTYPE TYPE STRING,
REACCOUNTINGOBJECT TYPE STRING,
REACCOUNTINGOBJIDENTIFICATION TYPE STRING,
REACCOUNTINGOBJECTTYPE TYPE STRING,
EXTERNALID TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTFIELDCHANGES TYPE STRING,END OF T_EKKO_STR. DATA: WA_VIBDOBJASS_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VIBDOBJASS_D_STR-MANDT sy-vline
WA_VIBDOBJASS_D_STR-RESTATUSOBJECTSOURCE sy-vline
WA_VIBDOBJASS_D_STR-REOBJECTASSIGNMENTTYPE sy-vline
WA_VIBDOBJASS_D_STR-RESTATUSOBJECTTARGET sy-vline
WA_VIBDOBJASS_D_STR-VALIDITYSTARTENDDATEVALUE sy-vline
WA_VIBDOBJASS_D_STR-INTERNALREALESTATENUMBER sy-vline
WA_VIBDOBJASS_D_STR-DRAFTUUID sy-vline
WA_VIBDOBJASS_D_STR-RESTATUSOBJECTTARGETFOREDIT sy-vline
WA_VIBDOBJASS_D_STR-REIDENTIFICATION sy-vline
WA_VIBDOBJASS_D_STR-PARENTDRAFTUUID sy-vline
WA_VIBDOBJASS_D_STR-VALIDITYSTARTDATE sy-vline
WA_VIBDOBJASS_D_STR-VALIDITYENDDATE sy-vline
WA_VIBDOBJASS_D_STR-REENTRYVALIDITY sy-vline
WA_VIBDOBJASS_D_STR-REENTRYVALIDITYCRITICALITY sy-vline
WA_VIBDOBJASS_D_STR-REOBJECTTYPETARGET sy-vline
WA_VIBDOBJASS_D_STR-REONLYINFOASSGMT sy-vline
WA_VIBDOBJASS_D_STR-REOBJECTPOSSESSIONSTARTDATE sy-vline
WA_VIBDOBJASS_D_STR-REOBJECTPOSSESSIONENDDATE sy-vline
WA_VIBDOBJASS_D_STR-REGROUPNUMBER sy-vline
WA_VIBDOBJASS_D_STR-REOBJECTGROUPNAME sy-vline
WA_VIBDOBJASS_D_STR-INTERNALREALESTATENUMBERTARGET sy-vline
WA_VIBDOBJASS_D_STR-RECONTRACTSUBJECTNUMBER sy-vline
WA_VIBDOBJASS_D_STR-RECONTRACTSUBJECTDESCRIPTION sy-vline
WA_VIBDOBJASS_D_STR-RECONTRACTSUBJECTCLASS sy-vline
WA_VIBDOBJASS_D_STR-RECONTRACTSUBJECTTYPE sy-vline
WA_VIBDOBJASS_D_STR-REACCOUNTINGOBJECT sy-vline
WA_VIBDOBJASS_D_STR-REACCOUNTINGOBJIDENTIFICATION sy-vline
WA_VIBDOBJASS_D_STR-REACCOUNTINGOBJECTTYPE sy-vline
WA_VIBDOBJASS_D_STR-EXTERNALID sy-vline
WA_VIBDOBJASS_D_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_VIBDOBJASS_D_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_VIBDOBJASS_D_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_VIBDOBJASS_D_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_VIBDOBJASS_D_STR-HASACTIVEENTITY sy-vline
WA_VIBDOBJASS_D_STR-DRAFTFIELDCHANGES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.