ABAP Select data from SAP table VIAK20 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VIAK20 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VIAK20. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VIAK20 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VIAK20 TYPE STANDARD TABLE OF VIAK20,
      WA_VIAK20 TYPE VIAK20,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VIAK20> TYPE VIAK20.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VIAK20.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VIAK20
  INTO TABLE IT_VIAK20.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VIAK20
*  INTO TABLE @DATA(IT_VIAK202).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VIAK20 INDEX 1 INTO DATA(WA_VIAK202).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VIAK20 ASSIGNING <VIAK20>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VIAK20>-MANDT = 1.
<VIAK20>-BUKRS = 1.
<VIAK20>-SMIVE = 1.
<VIAK20>-SWENR = 1.
<VIAK20>-SMENR = 1.
ENDLOOP.

LOOP AT IT_VIAK20 INTO WA_VIAK20.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VIAK20-SBEWART, sy-vline,
WA_VIAK20-DVONPER, sy-vline,
WA_VIAK20-NPERSOND, sy-vline,
WA_VIAK20-SNKSL, sy-vline,
WA_VIAK20-DBISPER, sy-vline,
WA_VIAK20-SKOART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VIAK20 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VIAK20 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VIAK20 INTO WA_VIAK20. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SMIVE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIAK20-SMIVE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIAK20-SMIVE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SWENR, internal->external for field SWENR CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_VIAK20-SWENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIAK20-SWENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SMENR, internal->external for field SMENR CALL FUNCTION 'CONVERSION_EXIT_SMENR_OUTPUT' EXPORTING input = WA_VIAK20-SMENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIAK20-SMENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SNKSL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIAK20-SNKSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIAK20-SNKSL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VIAK20_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
SMIVE TYPE STRING,
SWENR TYPE STRING,
SMENR TYPE STRING,
SBEWART TYPE STRING,
DVONPER TYPE STRING,
NPERSOND TYPE STRING,
SNKSL TYPE STRING,
DBISPER TYPE STRING,
SKOART TYPE STRING,
VVBKOPTG TYPE STRING,
BNETTO TYPE STRING,
BSTEUER TYPE STRING,
BHWHR TYPE STRING,
BGUFO TYPE STRING,
BMWST TYPE STRING,
MWSKZ TYPE STRING,
DVZNEU TYPE STRING,
BVZNEU TYPE STRING,
BKONDALT TYPE STRING,
VVSKVZA TYPE STRING,
DABRECH TYPE STRING,
VVABBLN TYPE STRING,
DMBTR TYPE STRING,
MWSTS TYPE STRING,
BNAVST TYPE STRING,
BSTBAS TYPE STRING,
BSTBTR TYPE STRING,
PERHVZ TYPE STRING,
BSTKORR TYPE STRING,
ABREART TYPE STRING,
TXJCD TYPE STRING,
MAXCOST TYPE STRING,
REBKOPTG TYPE STRING,
BNETTO_REAL TYPE STRING,
BSTBAS_REAL TYPE STRING,
BSTBTR_REAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_VIAK20_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VIAK20_STR-MANDT sy-vline
WA_VIAK20_STR-BUKRS sy-vline
WA_VIAK20_STR-SMIVE sy-vline
WA_VIAK20_STR-SWENR sy-vline
WA_VIAK20_STR-SMENR sy-vline
WA_VIAK20_STR-SBEWART sy-vline
WA_VIAK20_STR-DVONPER sy-vline
WA_VIAK20_STR-NPERSOND sy-vline
WA_VIAK20_STR-SNKSL sy-vline
WA_VIAK20_STR-DBISPER sy-vline
WA_VIAK20_STR-SKOART sy-vline
WA_VIAK20_STR-VVBKOPTG sy-vline
WA_VIAK20_STR-BNETTO sy-vline
WA_VIAK20_STR-BSTEUER sy-vline
WA_VIAK20_STR-BHWHR sy-vline
WA_VIAK20_STR-BGUFO sy-vline
WA_VIAK20_STR-BMWST sy-vline
WA_VIAK20_STR-MWSKZ sy-vline
WA_VIAK20_STR-DVZNEU sy-vline
WA_VIAK20_STR-BVZNEU sy-vline
WA_VIAK20_STR-BKONDALT sy-vline
WA_VIAK20_STR-VVSKVZA sy-vline
WA_VIAK20_STR-DABRECH sy-vline
WA_VIAK20_STR-VVABBLN sy-vline
WA_VIAK20_STR-DMBTR sy-vline
WA_VIAK20_STR-MWSTS sy-vline
WA_VIAK20_STR-BNAVST sy-vline
WA_VIAK20_STR-BSTBAS sy-vline
WA_VIAK20_STR-BSTBTR sy-vline
WA_VIAK20_STR-PERHVZ sy-vline
WA_VIAK20_STR-BSTKORR sy-vline
WA_VIAK20_STR-ABREART sy-vline
WA_VIAK20_STR-TXJCD sy-vline
WA_VIAK20_STR-MAXCOST sy-vline
WA_VIAK20_STR-REBKOPTG sy-vline
WA_VIAK20_STR-BNETTO_REAL sy-vline
WA_VIAK20_STR-BSTBAS_REAL sy-vline
WA_VIAK20_STR-BSTBTR_REAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.