ABAP Select data from SAP table VHUMI_QTY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VHUMI_QTY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VHUMI_QTY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VHUMI_QTY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VHUMI_QTY TYPE STANDARD TABLE OF VHUMI_QTY,
      WA_VHUMI_QTY TYPE VHUMI_QTY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VHUMI_QTY> TYPE VHUMI_QTY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VHUMI_QTY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VHUMI_QTY
  INTO TABLE IT_VHUMI_QTY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VHUMI_QTY
*  INTO TABLE @DATA(IT_VHUMI_QTY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VHUMI_QTY INDEX 1 INTO DATA(WA_VHUMI_QTY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VHUMI_QTY ASSIGNING <VHUMI_QTY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VHUMI_QTY>-VENUM = 1.
<VHUMI_QTY>-VEPOS = 1.
<VHUMI_QTY>-MENGE = 1.
<VHUMI_QTY>-MEINS = 1.
<VHUMI_QTY>-BERNR = 1.
ENDLOOP.

LOOP AT IT_VHUMI_QTY INTO WA_VHUMI_QTY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VHUMI_QTY-EXIDV_OB, sy-vline,
WA_VHUMI_QTY-AUFNR, sy-vline,
WA_VHUMI_QTY-/CWM/MENGE, sy-vline,
WA_VHUMI_QTY-/CWM/MEINS, sy-vline,
WA_VHUMI_QTY-WERKS, sy-vline,
ENDLOOP. *Add any further fields from structure WA_VHUMI_QTY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VHUMI_QTY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VHUMI_QTY INTO WA_VHUMI_QTY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VENUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VHUMI_QTY-VENUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VHUMI_QTY-VENUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VHUMI_QTY-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VHUMI_QTY-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXIDV_OB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VHUMI_QTY-EXIDV_OB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VHUMI_QTY-EXIDV_OB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VHUMI_QTY-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VHUMI_QTY-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field /CWM/MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VHUMI_QTY-/CWM/MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VHUMI_QTY-/CWM/MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VHUMI_QTY_STR,
VENUM TYPE STRING,
VEPOS TYPE STRING,
MENGE TYPE STRING,
MEINS TYPE STRING,
BERNR TYPE STRING,
EXIDV_OB TYPE STRING,
AUFNR TYPE STRING,
/CWM/MENGE TYPE STRING,
/CWM/MEINS TYPE STRING,
WERKS TYPE STRING,END OF T_EKKO_STR. DATA: WA_VHUMI_QTY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VHUMI_QTY_STR-VENUM sy-vline
WA_VHUMI_QTY_STR-VEPOS sy-vline
WA_VHUMI_QTY_STR-MENGE sy-vline
WA_VHUMI_QTY_STR-MEINS sy-vline
WA_VHUMI_QTY_STR-BERNR sy-vline
WA_VHUMI_QTY_STR-EXIDV_OB sy-vline
WA_VHUMI_QTY_STR-AUFNR sy-vline
WA_VHUMI_QTY_STR-/CWM/MENGE sy-vline
WA_VHUMI_QTY_STR-/CWM/MEINS sy-vline
WA_VHUMI_QTY_STR-WERKS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.