ABAP Select data from SAP table VH_PVCMP_SHLP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VH_PVCMP_SHLP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VH_PVCMP_SHLP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VH_PVCMP_SHLP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VH_PVCMP_SHLP TYPE STANDARD TABLE OF VH_PVCMP_SHLP,
      WA_VH_PVCMP_SHLP TYPE VH_PVCMP_SHLP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VH_PVCMP_SHLP> TYPE VH_PVCMP_SHLP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VH_PVCMP_SHLP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VH_PVCMP_SHLP
  INTO TABLE IT_VH_PVCMP_SHLP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VH_PVCMP_SHLP
*  INTO TABLE @DATA(IT_VH_PVCMP_SHLP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VH_PVCMP_SHLP INDEX 1 INTO DATA(WA_VH_PVCMP_SHLP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VH_PVCMP_SHLP ASSIGNING <VH_PVCMP_SHLP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VH_PVCMP_SHLP>-PVNAME = 1.
<VH_PVCMP_SHLP>-PVTYPE = 1.
<VH_PVCMP_SHLP>-CREADAT = 1.
<VH_PVCMP_SHLP>-CREABY = 1.
<VH_PVCMP_SHLP>-CHNGDAT = 1.
ENDLOOP.

LOOP AT IT_VH_PVCMP_SHLP INTO WA_VH_PVCMP_SHLP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VH_PVCMP_SHLP-CHNGBY, sy-vline,
WA_VH_PVCMP_SHLP-PNAME, sy-vline,
WA_VH_PVCMP_SHLP-AENNR, sy-vline,
WA_VH_PVCMP_SHLP-CLINT, sy-vline,
WA_VH_PVCMP_SHLP-PVGUID, sy-vline,
ENDLOOP. *Add any further fields from structure WA_VH_PVCMP_SHLP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VH_PVCMP_SHLP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VH_PVCMP_SHLP INTO WA_VH_PVCMP_SHLP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PVNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VH_PVCMP_SHLP-PVNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VH_PVCMP_SHLP-PVNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VH_PVCMP_SHLP-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VH_PVCMP_SHLP-AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VH_PVCMP_SHLP_STR,
PVNAME TYPE STRING,
PVTYPE TYPE STRING,
CREADAT TYPE STRING,
CREABY TYPE STRING,
CHNGDAT TYPE STRING,
CHNGBY TYPE STRING,
PNAME TYPE STRING,
AENNR TYPE STRING,
CLINT TYPE STRING,
PVGUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_VH_PVCMP_SHLP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VH_PVCMP_SHLP_STR-PVNAME sy-vline
WA_VH_PVCMP_SHLP_STR-PVTYPE sy-vline
WA_VH_PVCMP_SHLP_STR-CREADAT sy-vline
WA_VH_PVCMP_SHLP_STR-CREABY sy-vline
WA_VH_PVCMP_SHLP_STR-CHNGDAT sy-vline
WA_VH_PVCMP_SHLP_STR-CHNGBY sy-vline
WA_VH_PVCMP_SHLP_STR-PNAME sy-vline
WA_VH_PVCMP_SHLP_STR-AENNR sy-vline
WA_VH_PVCMP_SHLP_STR-CLINT sy-vline
WA_VH_PVCMP_SHLP_STR-PVGUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.