ABAP Select data from SAP table VDVZBAVF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VDVZBAVF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VDVZBAVF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VDVZBAVF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VDVZBAVF TYPE STANDARD TABLE OF VDVZBAVF,
      WA_VDVZBAVF TYPE VDVZBAVF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VDVZBAVF> TYPE VDVZBAVF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VDVZBAVF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VDVZBAVF
  INTO TABLE IT_VDVZBAVF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VDVZBAVF
*  INTO TABLE @DATA(IT_VDVZBAVF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VDVZBAVF INDEX 1 INTO DATA(WA_VDVZBAVF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VDVZBAVF ASSIGNING <VDVZBAVF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VDVZBAVF>-MANDT = 1.
<VDVZBAVF>-RANTYP = 1.
<VDVZBAVF>-VVKEY = 1.
<VDVZBAVF>-JDECK = 1.
<VDVZBAVF>-JBAVG = 1.
ENDLOOP.

LOOP AT IT_VDVZBAVF INTO WA_VDVZBAVF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VDVZBAVF-XAKTZBAV, sy-vline,
WA_VDVZBAVF-DBAVGEN, sy-vline,
WA_VDVZBAVF-SGBAV, sy-vline,
WA_VDVZBAVF-SBAV501, sy-vline,
WA_VDVZBAVF-SBILK, sy-vline,
WA_VDVZBAVF-JARW, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VDVZBAVF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VDVZBAVF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VDVZBAVF INTO WA_VDVZBAVF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VVKEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VDVZBAVF-VVKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VDVZBAVF-VVKEY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VDVZBAVF_STR,
MANDT TYPE STRING,
RANTYP TYPE STRING,
VVKEY TYPE STRING,
JDECK TYPE STRING,
JBAVG TYPE STRING,
XAKTZBAV TYPE STRING,
DBAVGEN TYPE STRING,
SGBAV TYPE STRING,
SBAV501 TYPE STRING,
SBILK TYPE STRING,
JARW TYPE STRING,
DARWGEN TYPE STRING,
XAKTZARW TYPE STRING,
XAUFORT TYPE STRING,
BARWBAV TYPE STRING,
SAWHR TYPE STRING,
DERWMEL TYPE STRING,
BVWERT TYPE STRING,
SVWHR TYPE STRING,
BARW_VU TYPE STRING,
SAWHR_VU TYPE STRING,
SNW101 TYPE STRING,
SNW102 TYPE STRING,
SNW201 TYPE STRING,
SJBUE TYPE STRING,
SNEU_ANL TYPE STRING,
XR5_91_1 TYPE STRING,
XR5_91_2 TYPE STRING,
XR5_91_3 TYPE STRING,
XTREU TYPE STRING,
XDECK TYPE STRING,
XARW TYPE STRING,
SMW102 TYPE STRING,
X_R97_03 TYPE STRING,
X_R97_05 TYPE STRING,
X_R97_06 TYPE STRING,
X_R97_08 TYPE STRING,
X_R97_101 TYPE STRING,
X_R97_102 TYPE STRING,
X_R97_103 TYPE STRING,
X_R97_104 TYPE STRING,
XTREU1 TYPE STRING,
KZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_VDVZBAVF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VDVZBAVF_STR-MANDT sy-vline
WA_VDVZBAVF_STR-RANTYP sy-vline
WA_VDVZBAVF_STR-VVKEY sy-vline
WA_VDVZBAVF_STR-JDECK sy-vline
WA_VDVZBAVF_STR-JBAVG sy-vline
WA_VDVZBAVF_STR-XAKTZBAV sy-vline
WA_VDVZBAVF_STR-DBAVGEN sy-vline
WA_VDVZBAVF_STR-SGBAV sy-vline
WA_VDVZBAVF_STR-SBAV501 sy-vline
WA_VDVZBAVF_STR-SBILK sy-vline
WA_VDVZBAVF_STR-JARW sy-vline
WA_VDVZBAVF_STR-DARWGEN sy-vline
WA_VDVZBAVF_STR-XAKTZARW sy-vline
WA_VDVZBAVF_STR-XAUFORT sy-vline
WA_VDVZBAVF_STR-BARWBAV sy-vline
WA_VDVZBAVF_STR-SAWHR sy-vline
WA_VDVZBAVF_STR-DERWMEL sy-vline
WA_VDVZBAVF_STR-BVWERT sy-vline
WA_VDVZBAVF_STR-SVWHR sy-vline
WA_VDVZBAVF_STR-BARW_VU sy-vline
WA_VDVZBAVF_STR-SAWHR_VU sy-vline
WA_VDVZBAVF_STR-SNW101 sy-vline
WA_VDVZBAVF_STR-SNW102 sy-vline
WA_VDVZBAVF_STR-SNW201 sy-vline
WA_VDVZBAVF_STR-SJBUE sy-vline
WA_VDVZBAVF_STR-SNEU_ANL sy-vline
WA_VDVZBAVF_STR-XR5_91_1 sy-vline
WA_VDVZBAVF_STR-XR5_91_2 sy-vline
WA_VDVZBAVF_STR-XR5_91_3 sy-vline
WA_VDVZBAVF_STR-XTREU sy-vline
WA_VDVZBAVF_STR-XDECK sy-vline
WA_VDVZBAVF_STR-XARW sy-vline
WA_VDVZBAVF_STR-SMW102 sy-vline
WA_VDVZBAVF_STR-X_R97_03 sy-vline
WA_VDVZBAVF_STR-X_R97_05 sy-vline
WA_VDVZBAVF_STR-X_R97_06 sy-vline
WA_VDVZBAVF_STR-X_R97_08 sy-vline
WA_VDVZBAVF_STR-X_R97_101 sy-vline
WA_VDVZBAVF_STR-X_R97_102 sy-vline
WA_VDVZBAVF_STR-X_R97_103 sy-vline
WA_VDVZBAVF_STR-X_R97_104 sy-vline
WA_VDVZBAVF_STR-XTREU1 sy-vline
WA_VDVZBAVF_STR-KZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.