ABAP Select data from SAP table VCOMM_CLEAR_STACK into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP VCOMM_CLEAR_STACK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VCOMM_CLEAR_STACK. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the VCOMM_CLEAR_STACK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_VCOMM_CLEAR_STACK TYPE STANDARD TABLE OF VCOMM_CLEAR_STACK,
WA_VCOMM_CLEAR_STACK TYPE VCOMM_CLEAR_STACK,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VCOMM_CLEAR_STACK> TYPE VCOMM_CLEAR_STACK.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_VCOMM_CLEAR_STACK.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM VCOMM_CLEAR_STACK
INTO TABLE IT_VCOMM_CLEAR_STACK.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM VCOMM_CLEAR_STACK
* INTO TABLE @DATA(IT_VCOMM_CLEAR_STACK2).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VCOMM_CLEAR_STACK INDEX 1 INTO DATA(WA_VCOMM_CLEAR_STACK2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VCOMM_CLEAR_STACK ASSIGNING <VCOMM_CLEAR_STACK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<VCOMM_CLEAR_STACK>-CLIENT = 1.
<VCOMM_CLEAR_STACK>-GUID = 1.
<VCOMM_CLEAR_STACK>-CASE_NUMBER = 1.
<VCOMM_CLEAR_STACK>-CASE_TYPE = 1.
<VCOMM_CLEAR_STACK>-ACTIVITY = 1.
ENDLOOP. LOOP AT IT_VCOMM_CLEAR_STACK INTO WA_VCOMM_CLEAR_STACK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_VCOMM_CLEAR_STACK-APPLICATION, sy-vline,
WA_VCOMM_CLEAR_STACK-SOURCE, sy-vline,
WA_VCOMM_CLEAR_STACK-ORIGINATOR, sy-vline,
WA_VCOMM_CLEAR_STACK-ADMINISTRATOR, sy-vline,
WA_VCOMM_CLEAR_STACK-NOTE, sy-vline,
WA_VCOMM_CLEAR_STACK-BUFFERED_DATA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VCOMM_CLEAR_STACK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VCOMM_CLEAR_STACK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VCOMM_CLEAR_STACK INTO WA_VCOMM_CLEAR_STACK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field CASE_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VCOMM_CLEAR_STACK-CASE_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCOMM_CLEAR_STACK-CASE_NUMBER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SOURCE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VCOMM_CLEAR_STACK-SOURCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCOMM_CLEAR_STACK-SOURCE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PCD_OBJECTCLAS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VCOMM_CLEAR_STACK-PCD_OBJECTCLAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCOMM_CLEAR_STACK-PCD_OBJECTCLAS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PCD_CHANGENR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VCOMM_CLEAR_STACK-PCD_CHANGENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCOMM_CLEAR_STACK-PCD_CHANGENR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field CREATE_TIME CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_VCOMM_CLEAR_STACK-CREATE_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCOMM_CLEAR_STACK-CREATE_TIME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field UPDATE_TIME CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_VCOMM_CLEAR_STACK-UPDATE_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCOMM_CLEAR_STACK-UPDATE_TIME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VCOMM_CLEAR_STACK_STR,
CLIENT TYPE STRING,
GUID TYPE STRING,
CASE_NUMBER TYPE STRING,
CASE_TYPE TYPE STRING,
ACTIVITY TYPE STRING,
APPLICATION TYPE STRING,
SOURCE TYPE STRING,
ORIGINATOR TYPE STRING,
ADMINISTRATOR TYPE STRING,
NOTE TYPE STRING,
BUFFERED_DATA TYPE STRING,
PCD_OBJECTCLAS TYPE STRING,
PCD_OBJECTID TYPE STRING,
PCD_CHANGENR TYPE STRING,
PRIORITY TYPE STRING,
ERROR_LOG TYPE STRING,
STATUS TYPE STRING,
DESCRIPTION TYPE STRING,
CREATE_TIME TYPE STRING,
UPDATE_TIME TYPE STRING,
KZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_VCOMM_CLEAR_STACK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VCOMM_CLEAR_STACK_STR-CLIENT sy-vline
WA_VCOMM_CLEAR_STACK_STR-GUID sy-vline
WA_VCOMM_CLEAR_STACK_STR-CASE_NUMBER sy-vline
WA_VCOMM_CLEAR_STACK_STR-CASE_TYPE sy-vline
WA_VCOMM_CLEAR_STACK_STR-ACTIVITY sy-vline
WA_VCOMM_CLEAR_STACK_STR-APPLICATION sy-vline
WA_VCOMM_CLEAR_STACK_STR-SOURCE sy-vline
WA_VCOMM_CLEAR_STACK_STR-ORIGINATOR sy-vline
WA_VCOMM_CLEAR_STACK_STR-ADMINISTRATOR sy-vline
WA_VCOMM_CLEAR_STACK_STR-NOTE sy-vline
WA_VCOMM_CLEAR_STACK_STR-BUFFERED_DATA sy-vline
WA_VCOMM_CLEAR_STACK_STR-PCD_OBJECTCLAS sy-vline
WA_VCOMM_CLEAR_STACK_STR-PCD_OBJECTID sy-vline
WA_VCOMM_CLEAR_STACK_STR-PCD_CHANGENR sy-vline
WA_VCOMM_CLEAR_STACK_STR-PRIORITY sy-vline
WA_VCOMM_CLEAR_STACK_STR-ERROR_LOG sy-vline
WA_VCOMM_CLEAR_STACK_STR-STATUS sy-vline
WA_VCOMM_CLEAR_STACK_STR-DESCRIPTION sy-vline
WA_VCOMM_CLEAR_STACK_STR-CREATE_TIME sy-vline
WA_VCOMM_CLEAR_STACK_STR-UPDATE_TIME sy-vline
WA_VCOMM_CLEAR_STACK_STR-KZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.
