ABAP Select data from SAP table VCHCLF_S_CSTIC_VALUE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VCHCLF_S_CSTIC_VALUE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VCHCLF_S_CSTIC_VALUE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VCHCLF_S_CSTIC_VALUE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VCHCLF_S_CSTIC_VALUE TYPE STANDARD TABLE OF VCHCLF_S_CSTIC_VALUE,
      WA_VCHCLF_S_CSTIC_VALUE TYPE VCHCLF_S_CSTIC_VALUE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VCHCLF_S_CSTIC_VALUE> TYPE VCHCLF_S_CSTIC_VALUE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VCHCLF_S_CSTIC_VALUE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VCHCLF_S_CSTIC_VALUE
  INTO TABLE IT_VCHCLF_S_CSTIC_VALUE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VCHCLF_S_CSTIC_VALUE
*  INTO TABLE @DATA(IT_VCHCLF_S_CSTIC_VALUE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VCHCLF_S_CSTIC_VALUE INDEX 1 INTO DATA(WA_VCHCLF_S_CSTIC_VALUE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VCHCLF_S_CSTIC_VALUE ASSIGNING <VCHCLF_S_CSTIC_VALUE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VCHCLF_S_CSTIC_VALUE>-CONTEXT_ID = 1.
<VCHCLF_S_CSTIC_VALUE>-INSTANCE_ID = 1.
<VCHCLF_S_CSTIC_VALUE>-GROUP_ID = 1.
<VCHCLF_S_CSTIC_VALUE>-CSTIC_ID = 1.
<VCHCLF_S_CSTIC_VALUE>-VALUE_ID = 1.
ENDLOOP.

LOOP AT IT_VCHCLF_S_CSTIC_VALUE INTO WA_VCHCLF_S_CSTIC_VALUE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VCHCLF_S_CSTIC_VALUE-DESCRIPTION, sy-vline,
WA_VCHCLF_S_CSTIC_VALUE-UNIT_FROM, sy-vline,
WA_VCHCLF_S_CSTIC_VALUE-UNIT_TO, sy-vline,
WA_VCHCLF_S_CSTIC_VALUE-INTERVAL_TYPE, sy-vline,
WA_VCHCLF_S_CSTIC_VALUE-HAS_LONG_TEXT, sy-vline,
WA_VCHCLF_S_CSTIC_VALUE-IS_INCONSISTENT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VCHCLF_S_CSTIC_VALUE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VCHCLF_S_CSTIC_VALUE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VCHCLF_S_CSTIC_VALUE INTO WA_VCHCLF_S_CSTIC_VALUE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit LUNIT, internal->external for field UNIT_FROM CALL FUNCTION 'CONVERSION_EXIT_LUNIT_OUTPUT' EXPORTING input = WA_VCHCLF_S_CSTIC_VALUE-UNIT_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCHCLF_S_CSTIC_VALUE-UNIT_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LUNIT, internal->external for field UNIT_TO CALL FUNCTION 'CONVERSION_EXIT_LUNIT_OUTPUT' EXPORTING input = WA_VCHCLF_S_CSTIC_VALUE-UNIT_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCHCLF_S_CSTIC_VALUE-UNIT_TO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VCHCLF_S_CSTIC_VALUE_STR,
CONTEXT_ID TYPE STRING,
INSTANCE_ID TYPE STRING,
GROUP_ID TYPE STRING,
CSTIC_ID TYPE STRING,
VALUE_ID TYPE STRING,
DESCRIPTION TYPE STRING,
UNIT_FROM TYPE STRING,
UNIT_TO TYPE STRING,
INTERVAL_TYPE TYPE STRING,
HAS_LONG_TEXT TYPE STRING,
IS_INCONSISTENT TYPE STRING,
CURRENCY TYPE STRING,
DEP_OBJ_NUMBER TYPE STRING,
IS_DEFAULT_VALUE TYPE STRING,
IS_EXCLUDED TYPE STRING,
IS_READONLY TYPE STRING,
IS_SET_BY_OBJ_DEP TYPE STRING,
FORMATTED_VALUE_FROM TYPE STRING,
FORMATTED_VALUE_TO TYPE STRING,
TECHNICAL_VALUE_FROM TYPE STRING,
TECHNICAL_VALUE_TO TYPE STRING,
TECHNICAL_VALUE TYPE STRING,
HAS_HIGH_PRECISION TYPE STRING,
IS_SELECTED TYPE STRING,
TECHNICAL_VALUE_DISPLAY TYPE STRING,
IS_MASTER_DATA_VALUE TYPE STRING,
EXCLUSION_TYPE TYPE STRING,
SORT_KEY TYPE STRING,
IS_PROPOSAL TYPE STRING,
PROPOSAL_CONFIDENCE TYPE STRING,END OF T_EKKO_STR. DATA: WA_VCHCLF_S_CSTIC_VALUE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-CONTEXT_ID sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-INSTANCE_ID sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-GROUP_ID sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-CSTIC_ID sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-VALUE_ID sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-DESCRIPTION sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-UNIT_FROM sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-UNIT_TO sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-INTERVAL_TYPE sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-HAS_LONG_TEXT sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-IS_INCONSISTENT sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-CURRENCY sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-DEP_OBJ_NUMBER sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-IS_DEFAULT_VALUE sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-IS_EXCLUDED sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-IS_READONLY sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-IS_SET_BY_OBJ_DEP sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-FORMATTED_VALUE_FROM sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-FORMATTED_VALUE_TO sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-TECHNICAL_VALUE_FROM sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-TECHNICAL_VALUE_TO sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-TECHNICAL_VALUE sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-HAS_HIGH_PRECISION sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-IS_SELECTED sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-TECHNICAL_VALUE_DISPLAY sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-IS_MASTER_DATA_VALUE sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-EXCLUSION_TYPE sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-SORT_KEY sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-IS_PROPOSAL sy-vline
WA_VCHCLF_S_CSTIC_VALUE_STR-PROPOSAL_CONFIDENCE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.