ABAP Select data from SAP table VCH_HL_S_CSTIC_VALUE_DOMAIN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VCH_HL_S_CSTIC_VALUE_DOMAIN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VCH_HL_S_CSTIC_VALUE_DOMAIN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VCH_HL_S_CSTIC_VALUE_DOMAIN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VCH_HL_S_CSTIC_VALUE_DOMAIN TYPE STANDARD TABLE OF VCH_HL_S_CSTIC_VALUE_DOMAIN,
      WA_VCH_HL_S_CSTIC_VALUE_DOMAIN TYPE VCH_HL_S_CSTIC_VALUE_DOMAIN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VCH_HL_S_CSTIC_VALUE_DOMAIN> TYPE VCH_HL_S_CSTIC_VALUE_DOMAIN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VCH_HL_S_CSTIC_VALUE_DOMAIN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VCH_HL_S_CSTIC_VALUE_DOMAIN
  INTO TABLE IT_VCH_HL_S_CSTIC_VALUE_DOMAIN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VCH_HL_S_CSTIC_VALUE_DOMAIN
*  INTO TABLE @DATA(IT_VCH_HL_S_CSTIC_VALUE_DOMAIN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VCH_HL_S_CSTIC_VALUE_DOMAIN INDEX 1 INTO DATA(WA_VCH_HL_S_CSTIC_VALUE_DOMAIN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VCH_HL_S_CSTIC_VALUE_DOMAIN ASSIGNING <VCH_HL_S_CSTIC_VALUE_DOMAIN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VCH_HL_S_CSTIC_VALUE_DOMAIN>-INSTANCE_ID = 1.
<VCH_HL_S_CSTIC_VALUE_DOMAIN>-CSTIC_ID = 1.
<VCH_HL_S_CSTIC_VALUE_DOMAIN>-VALUE_ID = 1.
<VCH_HL_S_CSTIC_VALUE_DOMAIN>-VALUE_STRING = 1.
<VCH_HL_S_CSTIC_VALUE_DOMAIN>-VALUE_INT_MIN = 1.
ENDLOOP.

LOOP AT IT_VCH_HL_S_CSTIC_VALUE_DOMAIN INTO WA_VCH_HL_S_CSTIC_VALUE_DOMAIN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VCH_HL_S_CSTIC_VALUE_DOMAIN-VALUE_INT_MAX, sy-vline,
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN-VALUE_FLOAT_MIN, sy-vline,
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN-VALUE_FLOAT_MAX, sy-vline,
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN-VALUE_DATE_MIN, sy-vline,
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN-VALUE_DATE_MAX, sy-vline,
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN-VALUE_TIME_MIN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VCH_HL_S_CSTIC_VALUE_DOMAIN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VCH_HL_S_CSTIC_VALUE_DOMAIN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VCH_HL_S_CSTIC_VALUE_DOMAIN INTO WA_VCH_HL_S_CSTIC_VALUE_DOMAIN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASURE_MIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VCH_HL_S_CSTIC_VALUE_DOMAIN-UNIT_OF_MEASURE_MIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCH_HL_S_CSTIC_VALUE_DOMAIN-UNIT_OF_MEASURE_MIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASURE_MAX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VCH_HL_S_CSTIC_VALUE_DOMAIN-UNIT_OF_MEASURE_MAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VCH_HL_S_CSTIC_VALUE_DOMAIN-UNIT_OF_MEASURE_MAX.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR,
INSTANCE_ID TYPE STRING,
CSTIC_ID TYPE STRING,
VALUE_ID TYPE STRING,
VALUE_STRING TYPE STRING,
VALUE_INT_MIN TYPE STRING,
VALUE_INT_MAX TYPE STRING,
VALUE_FLOAT_MIN TYPE STRING,
VALUE_FLOAT_MAX TYPE STRING,
VALUE_DATE_MIN TYPE STRING,
VALUE_DATE_MAX TYPE STRING,
VALUE_TIME_MIN TYPE STRING,
VALUE_TIME_MAX TYPE STRING,
INTERVAL_TYPE TYPE STRING,
UNIT_OF_MEASURE_MIN TYPE STRING,
UNIT_OF_MEASURE_MAX TYPE STRING,
CURRENCY_MIN TYPE STRING,
CURRENCY_MAX TYPE STRING,
ASSIGNMENT_TYPE TYPE STRING,
IS_EXCLUDED TYPE STRING,
REFERENCE_VALUE_ID TYPE STRING,
SORT_KEY TYPE STRING,
DOMAIN_CHANGE_TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-INSTANCE_ID sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-CSTIC_ID sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-VALUE_ID sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-VALUE_STRING sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-VALUE_INT_MIN sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-VALUE_INT_MAX sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-VALUE_FLOAT_MIN sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-VALUE_FLOAT_MAX sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-VALUE_DATE_MIN sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-VALUE_DATE_MAX sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-VALUE_TIME_MIN sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-VALUE_TIME_MAX sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-INTERVAL_TYPE sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-UNIT_OF_MEASURE_MIN sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-UNIT_OF_MEASURE_MAX sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-CURRENCY_MIN sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-CURRENCY_MAX sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-ASSIGNMENT_TYPE sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-IS_EXCLUDED sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-REFERENCE_VALUE_ID sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-SORT_KEY sy-vline
WA_VCH_HL_S_CSTIC_VALUE_DOMAIN_STR-DOMAIN_CHANGE_TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.