ABAP Select data from SAP table VBPV_E into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VBPV_E table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VBPV_E. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VBPV_E table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VBPV_E TYPE STANDARD TABLE OF VBPV_E,
      WA_VBPV_E TYPE VBPV_E,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VBPV_E> TYPE VBPV_E.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VBPV_E.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VBPV_E
  INTO TABLE IT_VBPV_E.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VBPV_E
*  INTO TABLE @DATA(IT_VBPV_E2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VBPV_E INDEX 1 INTO DATA(WA_VBPV_E2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VBPV_E ASSIGNING <VBPV_E>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VBPV_E>-MANDT = 1.
<VBPV_E>-VKORG = 1.
<VBPV_E>-VTWEG = 1.
<VBPV_E>-SPART = 1.
<VBPV_E>-KUNNR = 1.
ENDLOOP.

LOOP AT IT_VBPV_E INTO WA_VBPV_E.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VBPV_E-AUART, sy-vline,
WA_VBPV_E-MATNR, sy-vline,
WA_VBPV_E-CHARG, sy-vline,
WA_VBPV_E-PVMNG01, sy-vline,
WA_VBPV_E-PVMNG02, sy-vline,
WA_VBPV_E-PVMNG03, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VBPV_E you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VBPV_E TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VBPV_E INTO WA_VBPV_E. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VBPV_E-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VBPV_E-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AUART, internal->external for field AUART CALL FUNCTION 'CONVERSION_EXIT_AUART_OUTPUT' EXPORTING input = WA_VBPV_E-AUART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VBPV_E-AUART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_VBPV_E-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VBPV_E-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PVVRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VBPV_E-PVVRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VBPV_E-PVVRKME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VBPV_E_STR,
MANDT TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
KUNNR TYPE STRING,
AUART TYPE STRING,
MATNR TYPE STRING,
CHARG TYPE STRING,
PVMNG01 TYPE STRING,
PVMNG02 TYPE STRING,
PVMNG03 TYPE STRING,
PVMNG04 TYPE STRING,
PVMNG05 TYPE STRING,
PVMNG06 TYPE STRING,
PVMNG07 TYPE STRING,
PVMNG08 TYPE STRING,
PVMNG09 TYPE STRING,
PVMNG10 TYPE STRING,
PVMNG11 TYPE STRING,
PVMNG12 TYPE STRING,
PVVRKME TYPE STRING,
PVHKN TYPE STRING,
PVSRT TYPE STRING,
VBTYP TYPE STRING,
ERDAT TYPE STRING,
NETWR TYPE STRING,
WAERK TYPE STRING,END OF T_EKKO_STR. DATA: WA_VBPV_E_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VBPV_E_STR-MANDT sy-vline
WA_VBPV_E_STR-VKORG sy-vline
WA_VBPV_E_STR-VTWEG sy-vline
WA_VBPV_E_STR-SPART sy-vline
WA_VBPV_E_STR-KUNNR sy-vline
WA_VBPV_E_STR-AUART sy-vline
WA_VBPV_E_STR-MATNR sy-vline
WA_VBPV_E_STR-CHARG sy-vline
WA_VBPV_E_STR-PVMNG01 sy-vline
WA_VBPV_E_STR-PVMNG02 sy-vline
WA_VBPV_E_STR-PVMNG03 sy-vline
WA_VBPV_E_STR-PVMNG04 sy-vline
WA_VBPV_E_STR-PVMNG05 sy-vline
WA_VBPV_E_STR-PVMNG06 sy-vline
WA_VBPV_E_STR-PVMNG07 sy-vline
WA_VBPV_E_STR-PVMNG08 sy-vline
WA_VBPV_E_STR-PVMNG09 sy-vline
WA_VBPV_E_STR-PVMNG10 sy-vline
WA_VBPV_E_STR-PVMNG11 sy-vline
WA_VBPV_E_STR-PVMNG12 sy-vline
WA_VBPV_E_STR-PVVRKME sy-vline
WA_VBPV_E_STR-PVHKN sy-vline
WA_VBPV_E_STR-PVSRT sy-vline
WA_VBPV_E_STR-VBTYP sy-vline
WA_VBPV_E_STR-ERDAT sy-vline
WA_VBPV_E_STR-NETWR sy-vline
WA_VBPV_E_STR-WAERK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.