ABAP Select data from SAP table VBCP12 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VBCP12 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VBCP12. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VBCP12 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VBCP12 TYPE STANDARD TABLE OF VBCP12,
      WA_VBCP12 TYPE VBCP12,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VBCP12> TYPE VBCP12.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VBCP12.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VBCP12
  INTO TABLE IT_VBCP12.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VBCP12
*  INTO TABLE @DATA(IT_VBCP122).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VBCP12 INDEX 1 INTO DATA(WA_VBCP122).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VBCP12 ASSIGNING <VBCP12>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VBCP12>-FLG_MCHP = 1.
<VBCP12>-FLG_VERS = 1.
<VBCP12>-FLG_VERST = 1.
<VBCP12>-FLG_CONN = 1.
<VBCP12>-FLG_SIGN = 1.
ENDLOOP.

LOOP AT IT_VBCP12 INTO WA_VBCP12.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VBCP12-FLG_CONVERT_ONLY, sy-vline,
ENDLOOP. *Add any further fields from structure WA_VBCP12 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VBCP12 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VBCP12 INTO WA_VBCP12. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VBCP12_STR,
FLG_MCHP TYPE STRING,
FLG_VERS TYPE STRING,
FLG_VERST TYPE STRING,
FLG_CONN TYPE STRING,
FLG_SIGN TYPE STRING,
FLG_CONVERT_ONLY TYPE STRING,END OF T_EKKO_STR. DATA: WA_VBCP12_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VBCP12_STR-FLG_MCHP sy-vline
WA_VBCP12_STR-FLG_VERS sy-vline
WA_VBCP12_STR-FLG_VERST sy-vline
WA_VBCP12_STR-FLG_CONN sy-vline
WA_VBCP12_STR-FLG_SIGN sy-vline
WA_VBCP12_STR-FLG_CONVERT_ONLY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.