ABAP Select data from SAP table VALS_NEW_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VALS_NEW_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VALS_NEW_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VALS_NEW_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VALS_NEW_DATA TYPE STANDARD TABLE OF VALS_NEW_DATA,
      WA_VALS_NEW_DATA TYPE VALS_NEW_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VALS_NEW_DATA> TYPE VALS_NEW_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VALS_NEW_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VALS_NEW_DATA
  INTO TABLE IT_VALS_NEW_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VALS_NEW_DATA
*  INTO TABLE @DATA(IT_VALS_NEW_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VALS_NEW_DATA INDEX 1 INTO DATA(WA_VALS_NEW_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VALS_NEW_DATA ASSIGNING <VALS_NEW_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VALS_NEW_DATA>-NAM_VALUE_CL = 1.
<VALS_NEW_DATA>-NAM_VALUE_PC = 1.
<VALS_NEW_DATA>-NAM_VALUE_VC = 1.
<VALS_NEW_DATA>-NAQV_VC = 1.
<VALS_NEW_DATA>-NAQV_PC = 1.
ENDLOOP.

LOOP AT IT_VALS_NEW_DATA INTO WA_VALS_NEW_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VALS_NEW_DATA-NBV_EC_CL, sy-vline,
WA_VALS_NEW_DATA-NBV_EC_PC, sy-vline,
WA_VALS_NEW_DATA-NBV_EC_VC, sy-vline,
WA_VALS_NEW_DATA-NBV_CO_PC, sy-vline,
WA_VALS_NEW_DATA-NBV_CO_VC, sy-vline,
WA_VALS_NEW_DATA-NBP_EC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VALS_NEW_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VALS_NEW_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VALS_NEW_DATA INTO WA_VALS_NEW_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit EXCRT, internal->external for field NBR_FE CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_VALS_NEW_DATA-NBR_FE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VALS_NEW_DATA-NBR_FE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VALS_NEW_DATA_STR,
NAM_VALUE_CL TYPE STRING,
NAM_VALUE_PC TYPE STRING,
NAM_VALUE_VC TYPE STRING,
NAQV_VC TYPE STRING,
NAQV_PC TYPE STRING,
NBV_EC_CL TYPE STRING,
NBV_EC_PC TYPE STRING,
NBV_EC_VC TYPE STRING,
NBV_CO_PC TYPE STRING,
NBV_CO_VC TYPE STRING,
NBP_EC TYPE STRING,
NBR_FE TYPE STRING,
NBR_FE_F TYPE STRING,
NVM_VC TYPE STRING,
NHADJ_CL TYPE STRING,
NHADJ_PC TYPE STRING,
NHADJ_VC TYPE STRING,
NLOSS_ALLOW_PC TYPE STRING,
NLOSS_ALLOW_INDX_PC TYPE STRING,
NLOSS_ALLOW_VC TYPE STRING,
NAM_AD_LOSS_ALLOW_PC TYPE STRING,
NAM_AD_LOSS_ALLOW_INDX_PC TYPE STRING,
NAM_AD_LOSS_ALLOW_VC TYPE STRING,
NOFFS_LOSS_ALLOW_PC TYPE STRING,
NOFFS_LOSS_ALLOW_INDX_PC TYPE STRING,
NOFFS_LOSS_ALLOW_VC TYPE STRING,
NWRITEOFF_PC TYPE STRING,
NWRITEOFF_INDX_PC TYPE STRING,
NWRITEOFF_VC TYPE STRING,END OF T_EKKO_STR. DATA: WA_VALS_NEW_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VALS_NEW_DATA_STR-NAM_VALUE_CL sy-vline
WA_VALS_NEW_DATA_STR-NAM_VALUE_PC sy-vline
WA_VALS_NEW_DATA_STR-NAM_VALUE_VC sy-vline
WA_VALS_NEW_DATA_STR-NAQV_VC sy-vline
WA_VALS_NEW_DATA_STR-NAQV_PC sy-vline
WA_VALS_NEW_DATA_STR-NBV_EC_CL sy-vline
WA_VALS_NEW_DATA_STR-NBV_EC_PC sy-vline
WA_VALS_NEW_DATA_STR-NBV_EC_VC sy-vline
WA_VALS_NEW_DATA_STR-NBV_CO_PC sy-vline
WA_VALS_NEW_DATA_STR-NBV_CO_VC sy-vline
WA_VALS_NEW_DATA_STR-NBP_EC sy-vline
WA_VALS_NEW_DATA_STR-NBR_FE sy-vline
WA_VALS_NEW_DATA_STR-NBR_FE_F sy-vline
WA_VALS_NEW_DATA_STR-NVM_VC sy-vline
WA_VALS_NEW_DATA_STR-NHADJ_CL sy-vline
WA_VALS_NEW_DATA_STR-NHADJ_PC sy-vline
WA_VALS_NEW_DATA_STR-NHADJ_VC sy-vline
WA_VALS_NEW_DATA_STR-NLOSS_ALLOW_PC sy-vline
WA_VALS_NEW_DATA_STR-NLOSS_ALLOW_INDX_PC sy-vline
WA_VALS_NEW_DATA_STR-NLOSS_ALLOW_VC sy-vline
WA_VALS_NEW_DATA_STR-NAM_AD_LOSS_ALLOW_PC sy-vline
WA_VALS_NEW_DATA_STR-NAM_AD_LOSS_ALLOW_INDX_PC sy-vline
WA_VALS_NEW_DATA_STR-NAM_AD_LOSS_ALLOW_VC sy-vline
WA_VALS_NEW_DATA_STR-NOFFS_LOSS_ALLOW_PC sy-vline
WA_VALS_NEW_DATA_STR-NOFFS_LOSS_ALLOW_INDX_PC sy-vline
WA_VALS_NEW_DATA_STR-NOFFS_LOSS_ALLOW_VC sy-vline
WA_VALS_NEW_DATA_STR-NWRITEOFF_PC sy-vline
WA_VALS_NEW_DATA_STR-NWRITEOFF_INDX_PC sy-vline
WA_VALS_NEW_DATA_STR-NWRITEOFF_VC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.