ABAP Select data from SAP table V_WRFT_APC_GEN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_WRFT_APC_GEN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_WRFT_APC_GEN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_WRFT_APC_GEN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_WRFT_APC_GEN TYPE STANDARD TABLE OF V_WRFT_APC_GEN,
      WA_V_WRFT_APC_GEN TYPE V_WRFT_APC_GEN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_WRFT_APC_GEN> TYPE V_WRFT_APC_GEN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_WRFT_APC_GEN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_WRFT_APC_GEN
  INTO TABLE IT_V_WRFT_APC_GEN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_WRFT_APC_GEN
*  INTO TABLE @DATA(IT_V_WRFT_APC_GEN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_WRFT_APC_GEN INDEX 1 INTO DATA(WA_V_WRFT_APC_GEN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_WRFT_APC_GEN ASSIGNING <V_WRFT_APC_GEN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_WRFT_APC_GEN>-MANDT = 1.
<V_WRFT_APC_GEN>-EKERV = 1.
<V_WRFT_APC_GEN>-EKETX = 1.
<V_WRFT_APC_GEN>-VKERV = 1.
<V_WRFT_APC_GEN>-FIXINP = 1.
ENDLOOP.

LOOP AT IT_V_WRFT_APC_GEN INTO WA_V_WRFT_APC_GEN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_WRFT_APC_GEN-MINMKUP, sy-vline,
WA_V_WRFT_APC_GEN-MAXMKUP, sy-vline,
WA_V_WRFT_APC_GEN-NET_GROSS_FLAG, sy-vline,
WA_V_WRFT_APC_GEN-PPG_ROUND, sy-vline,
WA_V_WRFT_APC_GEN-MTART, sy-vline,
WA_V_WRFT_APC_GEN-MTBEZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_WRFT_APC_GEN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_WRFT_APC_GEN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_WRFT_APC_GEN INTO WA_V_WRFT_APC_GEN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_WRFT_APC_GEN_STR,
MANDT TYPE STRING,
EKERV TYPE STRING,
EKETX TYPE STRING,
VKERV TYPE STRING,
FIXINP TYPE STRING,
MINMKUP TYPE STRING,
MAXMKUP TYPE STRING,
NET_GROSS_FLAG TYPE STRING,
PPG_ROUND TYPE STRING,
MTART TYPE STRING,
MTBEZ TYPE STRING,
BSTAT TYPE STRING,
STBEZ TYPE STRING,
GR_TIME_DC TYPE STRING,
GI_TIME_DC TYPE STRING,
GR_TIME_ST TYPE STRING,
ODEL_PLPO TYPE STRING,
UDEL_PLPO TYPE STRING,
LISTCREATE TYPE STRING,
RFCDEST_BW TYPE STRING,
SAISO TYPE STRING,
EKERV_DIS TYPE STRING,
VKERV_DIS TYPE STRING,
LWBLINK TYPE STRING,
TOL_PLNASGN TYPE STRING,
SEQACT TYPE STRING,
SEQMAN TYPE STRING,
SEQREL TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_WRFT_APC_GEN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_WRFT_APC_GEN_STR-MANDT sy-vline
WA_V_WRFT_APC_GEN_STR-EKERV sy-vline
WA_V_WRFT_APC_GEN_STR-EKETX sy-vline
WA_V_WRFT_APC_GEN_STR-VKERV sy-vline
WA_V_WRFT_APC_GEN_STR-FIXINP sy-vline
WA_V_WRFT_APC_GEN_STR-MINMKUP sy-vline
WA_V_WRFT_APC_GEN_STR-MAXMKUP sy-vline
WA_V_WRFT_APC_GEN_STR-NET_GROSS_FLAG sy-vline
WA_V_WRFT_APC_GEN_STR-PPG_ROUND sy-vline
WA_V_WRFT_APC_GEN_STR-MTART sy-vline
WA_V_WRFT_APC_GEN_STR-MTBEZ sy-vline
WA_V_WRFT_APC_GEN_STR-BSTAT sy-vline
WA_V_WRFT_APC_GEN_STR-STBEZ sy-vline
WA_V_WRFT_APC_GEN_STR-GR_TIME_DC sy-vline
WA_V_WRFT_APC_GEN_STR-GI_TIME_DC sy-vline
WA_V_WRFT_APC_GEN_STR-GR_TIME_ST sy-vline
WA_V_WRFT_APC_GEN_STR-ODEL_PLPO sy-vline
WA_V_WRFT_APC_GEN_STR-UDEL_PLPO sy-vline
WA_V_WRFT_APC_GEN_STR-LISTCREATE sy-vline
WA_V_WRFT_APC_GEN_STR-RFCDEST_BW sy-vline
WA_V_WRFT_APC_GEN_STR-SAISO sy-vline
WA_V_WRFT_APC_GEN_STR-EKERV_DIS sy-vline
WA_V_WRFT_APC_GEN_STR-VKERV_DIS sy-vline
WA_V_WRFT_APC_GEN_STR-LWBLINK sy-vline
WA_V_WRFT_APC_GEN_STR-TOL_PLNASGN sy-vline
WA_V_WRFT_APC_GEN_STR-SEQACT sy-vline
WA_V_WRFT_APC_GEN_STR-SEQMAN sy-vline
WA_V_WRFT_APC_GEN_STR-SEQREL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.