ABAP Select data from SAP table V_WLFZUC10 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_WLFZUC10 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_WLFZUC10. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_WLFZUC10 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_WLFZUC10 TYPE STANDARD TABLE OF V_WLFZUC10,
      WA_V_WLFZUC10 TYPE V_WLFZUC10,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_WLFZUC10> TYPE V_WLFZUC10.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_WLFZUC10.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_WLFZUC10
  INTO TABLE IT_V_WLFZUC10.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_WLFZUC10
*  INTO TABLE @DATA(IT_V_WLFZUC102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_WLFZUC10 INDEX 1 INTO DATA(WA_V_WLFZUC102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_WLFZUC10 ASSIGNING <V_WLFZUC10>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_WLFZUC10>-MANDT = 1.
<V_WLFZUC10>-WBELN = 1.
<V_WLFZUC10>-WRART = 1.
<V_WLFZUC10>-WFDAT = 1.
<V_WLFZUC10>-LNRZB = 1.
ENDLOOP.

LOOP AT IT_V_WLFZUC10 INTO WA_V_WLFZUC10.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_WLFZUC10-KUNRG, sy-vline,
WA_V_WLFZUC10-EKORG, sy-vline,
WA_V_WLFZUC10-VKORG, sy-vline,
WA_V_WLFZUC10-VTWEG, sy-vline,
WA_V_WLFZUC10-SPART, sy-vline,
WA_V_WLFZUC10-BUKRS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_WLFZUC10 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_WLFZUC10 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_WLFZUC10 INTO WA_V_WLFZUC10. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field WBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_WLFZUC10-WBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_WLFZUC10-WBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LNRZB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_WLFZUC10-LNRZB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_WLFZUC10-LNRZB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNRG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_WLFZUC10-KUNRG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_WLFZUC10-KUNRG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFRE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_WLFZUC10-LIFRE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_WLFZUC10-LIFRE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNRE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_WLFZUC10-KUNRE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_WLFZUC10-KUNRE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_WLFZUC10_STR,
MANDT TYPE STRING,
WBELN TYPE STRING,
WRART TYPE STRING,
WFDAT TYPE STRING,
LNRZB TYPE STRING,
KUNRG TYPE STRING,
EKORG TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
BUKRS TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
EKGRP TYPE STRING,
LIFRE TYPE STRING,
KUNRE TYPE STRING,
XBLNR TYPE STRING,
ZUONR TYPE STRING,
BLDAT TYPE STRING,
RFBSK TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_WLFZUC10_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_WLFZUC10_STR-MANDT sy-vline
WA_V_WLFZUC10_STR-WBELN sy-vline
WA_V_WLFZUC10_STR-WRART sy-vline
WA_V_WLFZUC10_STR-WFDAT sy-vline
WA_V_WLFZUC10_STR-LNRZB sy-vline
WA_V_WLFZUC10_STR-KUNRG sy-vline
WA_V_WLFZUC10_STR-EKORG sy-vline
WA_V_WLFZUC10_STR-VKORG sy-vline
WA_V_WLFZUC10_STR-VTWEG sy-vline
WA_V_WLFZUC10_STR-SPART sy-vline
WA_V_WLFZUC10_STR-BUKRS sy-vline
WA_V_WLFZUC10_STR-ERDAT sy-vline
WA_V_WLFZUC10_STR-ERNAM sy-vline
WA_V_WLFZUC10_STR-EKGRP sy-vline
WA_V_WLFZUC10_STR-LIFRE sy-vline
WA_V_WLFZUC10_STR-KUNRE sy-vline
WA_V_WLFZUC10_STR-XBLNR sy-vline
WA_V_WLFZUC10_STR-ZUONR sy-vline
WA_V_WLFZUC10_STR-BLDAT sy-vline
WA_V_WLFZUC10_STR-RFBSK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.