ABAP Select data from SAP table V_VTB_FMOD_SFUNK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_VTB_FMOD_SFUNK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_VTB_FMOD_SFUNK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_VTB_FMOD_SFUNK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_VTB_FMOD_SFUNK TYPE STANDARD TABLE OF V_VTB_FMOD_SFUNK,
      WA_V_VTB_FMOD_SFUNK TYPE V_VTB_FMOD_SFUNK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_VTB_FMOD_SFUNK> TYPE V_VTB_FMOD_SFUNK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_VTB_FMOD_SFUNK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_VTB_FMOD_SFUNK
  INTO TABLE IT_V_VTB_FMOD_SFUNK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_VTB_FMOD_SFUNK
*  INTO TABLE @DATA(IT_V_VTB_FMOD_SFUNK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_VTB_FMOD_SFUNK INDEX 1 INTO DATA(WA_V_VTB_FMOD_SFUNK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_VTB_FMOD_SFUNK ASSIGNING <V_VTB_FMOD_SFUNK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_VTB_FMOD_SFUNK>-MANDT = 1.
<V_VTB_FMOD_SFUNK>-OBJAP = 1.
<V_VTB_FMOD_SFUNK>-BUKRS = 1.
<V_VTB_FMOD_SFUNK>-SGSART = 1.
<V_VTB_FMOD_SFUNK>-SFHAART = 1.
ENDLOOP.

LOOP AT IT_V_VTB_FMOD_SFUNK INTO WA_V_VTB_FMOD_SFUNK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_VTB_FMOD_SFUNK-SFGTYP, sy-vline,
WA_V_VTB_FMOD_SFUNK-SFGZUSTT, sy-vline,
WA_V_VTB_FMOD_SFUNK-SFUNKTL, sy-vline,
WA_V_VTB_FMOD_SFUNK-EDITMODE, sy-vline,
WA_V_VTB_FMOD_SFUNK-SANLFOR, sy-vline,
WA_V_VTB_FMOD_SFUNK-XFUNKTION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_VTB_FMOD_SFUNK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_VTB_FMOD_SFUNK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_VTB_FMOD_SFUNK INTO WA_V_VTB_FMOD_SFUNK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_VTB_FMOD_SFUNK_STR,
MANDT TYPE STRING,
OBJAP TYPE STRING,
BUKRS TYPE STRING,
SGSART TYPE STRING,
SFHAART TYPE STRING,
SFGTYP TYPE STRING,
SFGZUSTT TYPE STRING,
SFUNKTL TYPE STRING,
EDITMODE TYPE STRING,
SANLFOR TYPE STRING,
XFUNKTION TYPE STRING,
FMODID TYPE STRING,
XTEXT TYPE STRING,
LTX_SANLF TYPE STRING,
XTEXT_AT01 TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_VTB_FMOD_SFUNK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_VTB_FMOD_SFUNK_STR-MANDT sy-vline
WA_V_VTB_FMOD_SFUNK_STR-OBJAP sy-vline
WA_V_VTB_FMOD_SFUNK_STR-BUKRS sy-vline
WA_V_VTB_FMOD_SFUNK_STR-SGSART sy-vline
WA_V_VTB_FMOD_SFUNK_STR-SFHAART sy-vline
WA_V_VTB_FMOD_SFUNK_STR-SFGTYP sy-vline
WA_V_VTB_FMOD_SFUNK_STR-SFGZUSTT sy-vline
WA_V_VTB_FMOD_SFUNK_STR-SFUNKTL sy-vline
WA_V_VTB_FMOD_SFUNK_STR-EDITMODE sy-vline
WA_V_VTB_FMOD_SFUNK_STR-SANLFOR sy-vline
WA_V_VTB_FMOD_SFUNK_STR-XFUNKTION sy-vline
WA_V_VTB_FMOD_SFUNK_STR-FMODID sy-vline
WA_V_VTB_FMOD_SFUNK_STR-XTEXT sy-vline
WA_V_VTB_FMOD_SFUNK_STR-LTX_SANLF sy-vline
WA_V_VTB_FMOD_SFUNK_STR-XTEXT_AT01 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.