ABAP Select data from SAP table V_VIBDMEASBE_DS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_VIBDMEASBE_DS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_VIBDMEASBE_DS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_VIBDMEASBE_DS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_VIBDMEASBE_DS TYPE STANDARD TABLE OF V_VIBDMEASBE_DS,
      WA_V_VIBDMEASBE_DS TYPE V_VIBDMEASBE_DS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_VIBDMEASBE_DS> TYPE V_VIBDMEASBE_DS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_VIBDMEASBE_DS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_VIBDMEASBE_DS
  INTO TABLE IT_V_VIBDMEASBE_DS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_VIBDMEASBE_DS
*  INTO TABLE @DATA(IT_V_VIBDMEASBE_DS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_VIBDMEASBE_DS INDEX 1 INTO DATA(WA_V_VIBDMEASBE_DS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_VIBDMEASBE_DS ASSIGNING <V_VIBDMEASBE_DS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_VIBDMEASBE_DS>-MANDT = 1.
<V_VIBDMEASBE_DS>-INTRENO = 1.
<V_VIBDMEASBE_DS>-MEAS = 1.
<V_VIBDMEASBE_DS>-VALIDTO = 1.
<V_VIBDMEASBE_DS>-VALIDFROM = 1.
ENDLOOP.

LOOP AT IT_V_VIBDMEASBE_DS INTO WA_V_VIBDMEASBE_DS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_VIBDMEASBE_DS-MEASVALUE, sy-vline,
WA_V_VIBDMEASBE_DS-MEASVALUECMPL, sy-vline,
WA_V_VIBDMEASBE_DS-MEASUNIT, sy-vline,
WA_V_VIBDMEASBE_DS-ISMANUALLYSET, sy-vline,
WA_V_VIBDMEASBE_DS-ISHIERARCHICAL, sy-vline,
WA_V_VIBDMEASBE_DS-BUKRS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_VIBDMEASBE_DS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_VIBDMEASBE_DS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_VIBDMEASBE_DS INTO WA_V_VIBDMEASBE_DS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field MEAS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_VIBDMEASBE_DS-MEAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VIBDMEASBE_DS-MEAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_V_VIBDMEASBE_DS-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VIBDMEASBE_DS-VALIDTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_VIBDMEASBE_DS-MEASUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VIBDMEASBE_DS-MEASUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SWENR, internal->external for field SWENR CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_V_VIBDMEASBE_DS-SWENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VIBDMEASBE_DS-SWENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit IMKEY, internal->external for field IMKEY CALL FUNCTION 'CONVERSION_EXIT_IMKEY_OUTPUT' EXPORTING input = WA_V_VIBDMEASBE_DS-IMKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VIBDMEASBE_DS-IMKEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_VIBDMEASBE_DS-FEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VIBDMEASBE_DS-FEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field REINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_VIBDMEASBE_DS-REINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VIBDMEASBE_DS-REINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VVLEN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_VIBDMEASBE_DS-VVLEN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VIBDMEASBE_DS-VVLEN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RLRA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_VIBDMEASBE_DS-RLRA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VIBDMEASBE_DS-RLRA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field USGFUNCTION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_VIBDMEASBE_DS-USGFUNCTION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VIBDMEASBE_DS-USGFUNCTION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field VALIDTOBE CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_V_VIBDMEASBE_DS-VALIDTOBE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_VIBDMEASBE_DS-VALIDTOBE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_VIBDMEASBE_DS_STR,
MANDT TYPE STRING,
INTRENO TYPE STRING,
MEAS TYPE STRING,
VALIDTO TYPE STRING,
VALIDFROM TYPE STRING,
MEASVALUE TYPE STRING,
MEASVALUECMPL TYPE STRING,
MEASUNIT TYPE STRING,
ISMANUALLYSET TYPE STRING,
ISHIERARCHICAL TYPE STRING,
BUKRS TYPE STRING,
SWENR TYPE STRING,
OBJNR TYPE STRING,
IMKEY TYPE STRING,
CREATIONTYPE TYPE STRING,
RERF TYPE STRING,
DERF TYPE STRING,
TERF TYPE STRING,
REHER TYPE STRING,
RBEAR TYPE STRING,
DBEAR TYPE STRING,
TBEAR TYPE STRING,
RBHER TYPE STRING,
RESPONSIBLE TYPE STRING,
USEREXCLUSIVE TYPE STRING,
AUTHGRP TYPE STRING,
XWETEXT TYPE STRING,
WAERS TYPE STRING,
FEINS TYPE STRING,
REINS TYPE STRING,
VVLEN TYPE STRING,
SINSTBEZ TYPE STRING,
SSTDORT TYPE STRING,
SVERKEHR TYPE STRING,
SLAGEWE TYPE STRING,
SOBJLAGE TYPE STRING,
SMIETR TYPE STRING,
RLRA TYPE STRING,
VORBK TYPE STRING,
VORHK TYPE STRING,
XNOTPL TYPE STRING,
NEIGHBORH1 TYPE STRING,
NEIGHBORH2 TYPE STRING,
NEIGHBORH3 TYPE STRING,
USGFUNCTION TYPE STRING,
SECCO TYPE STRING,
BUPLA TYPE STRING,
VALIDFROMBE TYPE STRING,
VALIDTOBE TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_VIBDMEASBE_DS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_VIBDMEASBE_DS_STR-MANDT sy-vline
WA_V_VIBDMEASBE_DS_STR-INTRENO sy-vline
WA_V_VIBDMEASBE_DS_STR-MEAS sy-vline
WA_V_VIBDMEASBE_DS_STR-VALIDTO sy-vline
WA_V_VIBDMEASBE_DS_STR-VALIDFROM sy-vline
WA_V_VIBDMEASBE_DS_STR-MEASVALUE sy-vline
WA_V_VIBDMEASBE_DS_STR-MEASVALUECMPL sy-vline
WA_V_VIBDMEASBE_DS_STR-MEASUNIT sy-vline
WA_V_VIBDMEASBE_DS_STR-ISMANUALLYSET sy-vline
WA_V_VIBDMEASBE_DS_STR-ISHIERARCHICAL sy-vline
WA_V_VIBDMEASBE_DS_STR-BUKRS sy-vline
WA_V_VIBDMEASBE_DS_STR-SWENR sy-vline
WA_V_VIBDMEASBE_DS_STR-OBJNR sy-vline
WA_V_VIBDMEASBE_DS_STR-IMKEY sy-vline
WA_V_VIBDMEASBE_DS_STR-CREATIONTYPE sy-vline
WA_V_VIBDMEASBE_DS_STR-RERF sy-vline
WA_V_VIBDMEASBE_DS_STR-DERF sy-vline
WA_V_VIBDMEASBE_DS_STR-TERF sy-vline
WA_V_VIBDMEASBE_DS_STR-REHER sy-vline
WA_V_VIBDMEASBE_DS_STR-RBEAR sy-vline
WA_V_VIBDMEASBE_DS_STR-DBEAR sy-vline
WA_V_VIBDMEASBE_DS_STR-TBEAR sy-vline
WA_V_VIBDMEASBE_DS_STR-RBHER sy-vline
WA_V_VIBDMEASBE_DS_STR-RESPONSIBLE sy-vline
WA_V_VIBDMEASBE_DS_STR-USEREXCLUSIVE sy-vline
WA_V_VIBDMEASBE_DS_STR-AUTHGRP sy-vline
WA_V_VIBDMEASBE_DS_STR-XWETEXT sy-vline
WA_V_VIBDMEASBE_DS_STR-WAERS sy-vline
WA_V_VIBDMEASBE_DS_STR-FEINS sy-vline
WA_V_VIBDMEASBE_DS_STR-REINS sy-vline
WA_V_VIBDMEASBE_DS_STR-VVLEN sy-vline
WA_V_VIBDMEASBE_DS_STR-SINSTBEZ sy-vline
WA_V_VIBDMEASBE_DS_STR-SSTDORT sy-vline
WA_V_VIBDMEASBE_DS_STR-SVERKEHR sy-vline
WA_V_VIBDMEASBE_DS_STR-SLAGEWE sy-vline
WA_V_VIBDMEASBE_DS_STR-SOBJLAGE sy-vline
WA_V_VIBDMEASBE_DS_STR-SMIETR sy-vline
WA_V_VIBDMEASBE_DS_STR-RLRA sy-vline
WA_V_VIBDMEASBE_DS_STR-VORBK sy-vline
WA_V_VIBDMEASBE_DS_STR-VORHK sy-vline
WA_V_VIBDMEASBE_DS_STR-XNOTPL sy-vline
WA_V_VIBDMEASBE_DS_STR-NEIGHBORH1 sy-vline
WA_V_VIBDMEASBE_DS_STR-NEIGHBORH2 sy-vline
WA_V_VIBDMEASBE_DS_STR-NEIGHBORH3 sy-vline
WA_V_VIBDMEASBE_DS_STR-USGFUNCTION sy-vline
WA_V_VIBDMEASBE_DS_STR-SECCO sy-vline
WA_V_VIBDMEASBE_DS_STR-BUPLA sy-vline
WA_V_VIBDMEASBE_DS_STR-VALIDFROMBE sy-vline
WA_V_VIBDMEASBE_DS_STR-VALIDTOBE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.