ABAP Select data from SAP table V_TVCPLAP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TVCPLAP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TVCPLAP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_TVCPLAP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_TVCPLAP TYPE STANDARD TABLE OF V_TVCPLAP,
      WA_V_TVCPLAP TYPE V_TVCPLAP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_TVCPLAP> TYPE V_TVCPLAP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_TVCPLAP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_TVCPLAP
  INTO TABLE IT_V_TVCPLAP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_TVCPLAP
*  INTO TABLE @DATA(IT_V_TVCPLAP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_TVCPLAP INDEX 1 INTO DATA(WA_V_TVCPLAP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_TVCPLAP ASSIGNING <V_TVCPLAP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TVCPLAP>-MANDT = 1.
<V_TVCPLAP>-LFARN = 1.
<V_TVCPLAP>-AUARV = 1.
<V_TVCPLAP>-PSTYV = 1.
<V_TVCPLAP>-AUBED = 1.
ENDLOOP.

LOOP AT IT_V_TVCPLAP INTO WA_V_TVCPLAP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_TVCPLAP-AUZUS, sy-vline,
WA_V_TVCPLAP-ETBED, sy-vline,
WA_V_TVCPLAP-GRUAK, sy-vline,
WA_V_TVCPLAP-GRUAP, sy-vline,
WA_V_TVCPLAP-GRUKD, sy-vline,
WA_V_TVCPLAP-GRUET, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TVCPLAP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TVCPLAP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TVCPLAP INTO WA_V_TVCPLAP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit AUART, internal->external for field AUARV CALL FUNCTION 'CONVERSION_EXIT_AUART_OUTPUT' EXPORTING input = WA_V_TVCPLAP-AUARV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_TVCPLAP-AUARV.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TVCPLAP_STR,
MANDT TYPE STRING,
LFARN TYPE STRING,
AUARV TYPE STRING,
PSTYV TYPE STRING,
AUBED TYPE STRING,
AUZUS TYPE STRING,
ETBED TYPE STRING,
GRUAK TYPE STRING,
GRUAP TYPE STRING,
GRUKD TYPE STRING,
GRUET TYPE STRING,
POSVO TYPE STRING,
PLMIN TYPE STRING,
UPFLU TYPE STRING,
GRUVS TYPE STRING,
VTEXTA TYPE STRING,
VTEXTL TYPE STRING,
VTEXTP TYPE STRING,
GRUAK_AIP TYPE STRING,
GRUAP_AIP TYPE STRING,
FSH_VASCPY TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TVCPLAP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TVCPLAP_STR-MANDT sy-vline
WA_V_TVCPLAP_STR-LFARN sy-vline
WA_V_TVCPLAP_STR-AUARV sy-vline
WA_V_TVCPLAP_STR-PSTYV sy-vline
WA_V_TVCPLAP_STR-AUBED sy-vline
WA_V_TVCPLAP_STR-AUZUS sy-vline
WA_V_TVCPLAP_STR-ETBED sy-vline
WA_V_TVCPLAP_STR-GRUAK sy-vline
WA_V_TVCPLAP_STR-GRUAP sy-vline
WA_V_TVCPLAP_STR-GRUKD sy-vline
WA_V_TVCPLAP_STR-GRUET sy-vline
WA_V_TVCPLAP_STR-POSVO sy-vline
WA_V_TVCPLAP_STR-PLMIN sy-vline
WA_V_TVCPLAP_STR-UPFLU sy-vline
WA_V_TVCPLAP_STR-GRUVS sy-vline
WA_V_TVCPLAP_STR-VTEXTA sy-vline
WA_V_TVCPLAP_STR-VTEXTL sy-vline
WA_V_TVCPLAP_STR-VTEXTP sy-vline
WA_V_TVCPLAP_STR-GRUAK_AIP sy-vline
WA_V_TVCPLAP_STR-GRUAP_AIP sy-vline
WA_V_TVCPLAP_STR-FSH_VASCPY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.