ABAP Select data from SAP table V_TVCPFLP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TVCPFLP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TVCPFLP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_TVCPFLP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_TVCPFLP TYPE STANDARD TABLE OF V_TVCPFLP,
      WA_V_TVCPFLP TYPE V_TVCPFLP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_TVCPFLP> TYPE V_TVCPFLP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_TVCPFLP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_TVCPFLP
  INTO TABLE IT_V_TVCPFLP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_TVCPFLP
*  INTO TABLE @DATA(IT_V_TVCPFLP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_TVCPFLP INDEX 1 INTO DATA(WA_V_TVCPFLP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_TVCPFLP ASSIGNING <V_TVCPFLP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TVCPFLP>-MANDT = 1.
<V_TVCPFLP>-FKARN = 1.
<V_TVCPFLP>-AUARV = 1.
<V_TVCPFLP>-LFARV = 1.
<V_TVCPFLP>-FKARV = 1.
ENDLOOP.

LOOP AT IT_V_TVCPFLP INTO WA_V_TVCPFLP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_TVCPFLP-PSTYV, sy-vline,
WA_V_TVCPFLP-GRBED, sy-vline,
WA_V_TVCPFLP-GRURK, sy-vline,
WA_V_TVCPFLP-GRURP, sy-vline,
WA_V_TVCPFLP-GRUKO, sy-vline,
WA_V_TVCPFLP-KNPRS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TVCPFLP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TVCPFLP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TVCPFLP INTO WA_V_TVCPFLP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit AUART, internal->external for field AUARV CALL FUNCTION 'CONVERSION_EXIT_AUART_OUTPUT' EXPORTING input = WA_V_TVCPFLP-AUARV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_TVCPFLP-AUARV.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TVCPFLP_STR,
MANDT TYPE STRING,
FKARN TYPE STRING,
AUARV TYPE STRING,
LFARV TYPE STRING,
FKARV TYPE STRING,
PSTYV TYPE STRING,
GRBED TYPE STRING,
GRURK TYPE STRING,
GRURP TYPE STRING,
GRUKO TYPE STRING,
KNPRS TYPE STRING,
PLMIN TYPE STRING,
FKMGK TYPE STRING,
POSVO TYPE STRING,
HINEU TYPE STRING,
PFKUR TYPE STRING,
EXPIM TYPE STRING,
ORDNR_FI TYPE STRING,
XBLNR_FI TYPE STRING,
VTEXTL TYPE STRING,
VTEXTF TYPE STRING,
VTEXTP TYPE STRING,
KVPRS TYPE STRING,
PRSQU TYPE STRING,
OIFERP TYPE STRING,
OIFEECH TYPE STRING,
GRURP_2 TYPE STRING,
SDBIL_GRURP_ROUTINE_NO TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TVCPFLP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TVCPFLP_STR-MANDT sy-vline
WA_V_TVCPFLP_STR-FKARN sy-vline
WA_V_TVCPFLP_STR-AUARV sy-vline
WA_V_TVCPFLP_STR-LFARV sy-vline
WA_V_TVCPFLP_STR-FKARV sy-vline
WA_V_TVCPFLP_STR-PSTYV sy-vline
WA_V_TVCPFLP_STR-GRBED sy-vline
WA_V_TVCPFLP_STR-GRURK sy-vline
WA_V_TVCPFLP_STR-GRURP sy-vline
WA_V_TVCPFLP_STR-GRUKO sy-vline
WA_V_TVCPFLP_STR-KNPRS sy-vline
WA_V_TVCPFLP_STR-PLMIN sy-vline
WA_V_TVCPFLP_STR-FKMGK sy-vline
WA_V_TVCPFLP_STR-POSVO sy-vline
WA_V_TVCPFLP_STR-HINEU sy-vline
WA_V_TVCPFLP_STR-PFKUR sy-vline
WA_V_TVCPFLP_STR-EXPIM sy-vline
WA_V_TVCPFLP_STR-ORDNR_FI sy-vline
WA_V_TVCPFLP_STR-XBLNR_FI sy-vline
WA_V_TVCPFLP_STR-VTEXTL sy-vline
WA_V_TVCPFLP_STR-VTEXTF sy-vline
WA_V_TVCPFLP_STR-VTEXTP sy-vline
WA_V_TVCPFLP_STR-KVPRS sy-vline
WA_V_TVCPFLP_STR-PRSQU sy-vline
WA_V_TVCPFLP_STR-OIFERP sy-vline
WA_V_TVCPFLP_STR-OIFEECH sy-vline
WA_V_TVCPFLP_STR-GRURP_2 sy-vline
WA_V_TVCPFLP_STR-SDBIL_GRURP_ROUTINE_NO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.