ABAP Select data from SAP table V_TQ80_SM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TQ80_SM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TQ80_SM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_TQ80_SM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_TQ80_SM TYPE STANDARD TABLE OF V_TQ80_SM,
      WA_V_TQ80_SM TYPE V_TQ80_SM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_TQ80_SM> TYPE V_TQ80_SM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_TQ80_SM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_TQ80_SM
  INTO TABLE IT_V_TQ80_SM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_TQ80_SM
*  INTO TABLE @DATA(IT_V_TQ80_SM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_TQ80_SM INDEX 1 INTO DATA(WA_V_TQ80_SM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_TQ80_SM ASSIGNING <V_TQ80_SM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TQ80_SM>-MANDT = 1.
<V_TQ80_SM>-QMART = 1.
<V_TQ80_SM>-QMARTX = 1.
<V_TQ80_SM>-AUART = 1.
<V_TQ80_SM>-SDAUART = 1.
ENDLOOP.

LOOP AT IT_V_TQ80_SM INTO WA_V_TQ80_SM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_TQ80_SM-QMTYP, sy-vline,
WA_V_TQ80_SM-TXT, sy-vline,
WA_V_TQ80_SM-BEZEI, sy-vline,
WA_V_TQ80_SM-VTEXT, sy-vline,
WA_V_TQ80_SM-AUART2, sy-vline,
WA_V_TQ80_SM-AUTOM_CONT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TQ80_SM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TQ80_SM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TQ80_SM INTO WA_V_TQ80_SM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit AUART, internal->external for field SDAUART CALL FUNCTION 'CONVERSION_EXIT_AUART_OUTPUT' EXPORTING input = WA_V_TQ80_SM-SDAUART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_TQ80_SM-SDAUART.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TQ80_SM_STR,
MANDT TYPE STRING,
QMART TYPE STRING,
QMARTX TYPE STRING,
AUART TYPE STRING,
SDAUART TYPE STRING,
QMTYP TYPE STRING,
TXT TYPE STRING,
BEZEI TYPE STRING,
VTEXT TYPE STRING,
AUART2 TYPE STRING,
AUTOM_CONT TYPE STRING,
EARLY_NUM TYPE STRING,
CMCHECK_SM TYPE STRING,
CMGRA TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TQ80_SM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TQ80_SM_STR-MANDT sy-vline
WA_V_TQ80_SM_STR-QMART sy-vline
WA_V_TQ80_SM_STR-QMARTX sy-vline
WA_V_TQ80_SM_STR-AUART sy-vline
WA_V_TQ80_SM_STR-SDAUART sy-vline
WA_V_TQ80_SM_STR-QMTYP sy-vline
WA_V_TQ80_SM_STR-TXT sy-vline
WA_V_TQ80_SM_STR-BEZEI sy-vline
WA_V_TQ80_SM_STR-VTEXT sy-vline
WA_V_TQ80_SM_STR-AUART2 sy-vline
WA_V_TQ80_SM_STR-AUTOM_CONT sy-vline
WA_V_TQ80_SM_STR-EARLY_NUM sy-vline
WA_V_TQ80_SM_STR-CMCHECK_SM sy-vline
WA_V_TQ80_SM_STR-CMGRA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.