ABAP Select data from SAP table V_TNA30V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TNA30V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TNA30V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_TNA30V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_TNA30V TYPE STANDARD TABLE OF V_TNA30V,
      WA_V_TNA30V TYPE V_TNA30V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_TNA30V> TYPE V_TNA30V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_TNA30V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_TNA30V
  INTO TABLE IT_V_TNA30V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_TNA30V
*  INTO TABLE @DATA(IT_V_TNA30V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_TNA30V INDEX 1 INTO DATA(WA_V_TNA30V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_TNA30V ASSIGNING <V_TNA30V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TNA30V>-MANDT = 1.
<V_TNA30V>-EINRI = 1.
<V_TNA30V>-SELID = 1.
<V_TNA30V>-KOSTR = 1.
<V_TNA30V>-SKZ22 = 1.
ENDLOOP.

LOOP AT IT_V_TNA30V INTO WA_V_TNA30V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_TNA30V-SKZ23, sy-vline,
WA_V_TNA30V-SKZ24, sy-vline,
WA_V_TNA30V-SKZ25, sy-vline,
WA_V_TNA30V-SKZ26, sy-vline,
WA_V_TNA30V-SORTK, sy-vline,
WA_V_TNA30V-SOTXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TNA30V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TNA30V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TNA30V INTO WA_V_TNA30V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EINRI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_TNA30V-EINRI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_TNA30V-EINRI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_TNA30V-KOSTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_TNA30V-KOSTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TNA30V_STR,
MANDT TYPE STRING,
EINRI TYPE STRING,
SELID TYPE STRING,
KOSTR TYPE STRING,
SKZ22 TYPE STRING,
SKZ23 TYPE STRING,
SKZ24 TYPE STRING,
SKZ25 TYPE STRING,
SKZ26 TYPE STRING,
SORTK TYPE STRING,
SOTXT TYPE STRING,
SOZKO TYPE STRING,
ZEILE TYPE STRING,
EINKB TYPE STRING,
KTEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TNA30V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TNA30V_STR-MANDT sy-vline
WA_V_TNA30V_STR-EINRI sy-vline
WA_V_TNA30V_STR-SELID sy-vline
WA_V_TNA30V_STR-KOSTR sy-vline
WA_V_TNA30V_STR-SKZ22 sy-vline
WA_V_TNA30V_STR-SKZ23 sy-vline
WA_V_TNA30V_STR-SKZ24 sy-vline
WA_V_TNA30V_STR-SKZ25 sy-vline
WA_V_TNA30V_STR-SKZ26 sy-vline
WA_V_TNA30V_STR-SORTK sy-vline
WA_V_TNA30V_STR-SOTXT sy-vline
WA_V_TNA30V_STR-SOZKO sy-vline
WA_V_TNA30V_STR-ZEILE sy-vline
WA_V_TNA30V_STR-EINKB sy-vline
WA_V_TNA30V_STR-KTEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.