ABAP Select data from SAP table V_TFPLT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TFPLT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TFPLT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_TFPLT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_TFPLT TYPE STANDARD TABLE OF V_TFPLT,
      WA_V_TFPLT TYPE V_TFPLT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_TFPLT> TYPE V_TFPLT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_TFPLT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_TFPLT
  INTO TABLE IT_V_TFPLT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_TFPLT
*  INTO TABLE @DATA(IT_V_TFPLT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_TFPLT INDEX 1 INTO DATA(WA_V_TFPLT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_TFPLT ASSIGNING <V_TFPLT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TFPLT>-MANDT = 1.
<V_TFPLT>-FPART = 1.
<V_TFPLT>-FPTTP = 1.
<V_TFPLT>-TETXT = 1.
<V_TFPLT>-FPFIX = 1.
ENDLOOP.

LOOP AT IT_V_TFPLT INTO WA_V_TFPLT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_TFPLT-FAREG, sy-vline,
WA_V_TFPLT-FAKSP, sy-vline,
WA_V_TFPLT-FKARV, sy-vline,
WA_V_TFPLT-AUTTD, sy-vline,
WA_V_TFPLT-AUTTE, sy-vline,
WA_V_TFPLT-PERIO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TFPLT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TFPLT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TFPLT INTO WA_V_TFPLT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TFPLT_STR,
MANDT TYPE STRING,
FPART TYPE STRING,
FPTTP TYPE STRING,
TETXT TYPE STRING,
FPFIX TYPE STRING,
FAREG TYPE STRING,
FAKSP TYPE STRING,
FKARV TYPE STRING,
AUTTD TYPE STRING,
AUTTE TYPE STRING,
PERIO TYPE STRING,
FPLAE TYPE STRING,
TTBEZ TYPE STRING,
TEBEZ TYPE STRING,
BEZEICH TYPE STRING,
FPBEZ TYPE STRING,
KSTEU TYPE STRING,
PERIO_FPLA TYPE STRING,
FPTYP TYPE STRING,
FKARK TYPE STRING,
FAKSK TYPE STRING,
LIFSP TYPE STRING,
BOMDLVGRP TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TFPLT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TFPLT_STR-MANDT sy-vline
WA_V_TFPLT_STR-FPART sy-vline
WA_V_TFPLT_STR-FPTTP sy-vline
WA_V_TFPLT_STR-TETXT sy-vline
WA_V_TFPLT_STR-FPFIX sy-vline
WA_V_TFPLT_STR-FAREG sy-vline
WA_V_TFPLT_STR-FAKSP sy-vline
WA_V_TFPLT_STR-FKARV sy-vline
WA_V_TFPLT_STR-AUTTD sy-vline
WA_V_TFPLT_STR-AUTTE sy-vline
WA_V_TFPLT_STR-PERIO sy-vline
WA_V_TFPLT_STR-FPLAE sy-vline
WA_V_TFPLT_STR-TTBEZ sy-vline
WA_V_TFPLT_STR-TEBEZ sy-vline
WA_V_TFPLT_STR-BEZEICH sy-vline
WA_V_TFPLT_STR-FPBEZ sy-vline
WA_V_TFPLT_STR-KSTEU sy-vline
WA_V_TFPLT_STR-PERIO_FPLA sy-vline
WA_V_TFPLT_STR-FPTYP sy-vline
WA_V_TFPLT_STR-FKARK sy-vline
WA_V_TFPLT_STR-FAKSK sy-vline
WA_V_TFPLT_STR-LIFSP sy-vline
WA_V_TFPLT_STR-BOMDLVGRP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.