ABAP Select data from SAP table V_TF600 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TF600 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TF600. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_TF600 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_TF600 TYPE STANDARD TABLE OF V_TF600,
      WA_V_TF600 TYPE V_TF600,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_TF600> TYPE V_TF600.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_TF600.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_TF600
  INTO TABLE IT_V_TF600.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_TF600
*  INTO TABLE @DATA(IT_V_TF6002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_TF600 INDEX 1 INTO DATA(WA_V_TF6002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_TF600 ASSIGNING <V_TF600>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TF600>-MANDT = 1.
<V_TF600>-DIMEN = 1.
<V_TF600>-COIMETH = 1.
<V_TF600>-CACTT = 1.
<V_TF600>-TXT = 1.
ENDLOOP.

LOOP AT IT_V_TF600 INTO WA_V_TF600.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_TF600-COITP, sy-vline,
WA_V_TF600-USGAAP, sy-vline,
WA_V_TF600-GWPROC, sy-vline,
WA_V_TF600-NGPROC, sy-vline,
WA_V_TF600-GWLCFLG, sy-vline,
WA_V_TF600-GWIEFLG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TF600 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TF600 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TF600 INTO WA_V_TF600. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit AC172, internal->external for field GWALVAL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_V_TF600-GWALVAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_TF600-GWALVAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field GWRLVAL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_V_TF600-GWRLVAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_TF600-GWRLVAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field NGALVAL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_V_TF600-NGALVAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_TF600-NGALVAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field NGRLVAL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_V_TF600-NGRLVAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_TF600-NGRLVAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TF600_STR,
MANDT TYPE STRING,
DIMEN TYPE STRING,
COIMETH TYPE STRING,
CACTT TYPE STRING,
TXT TYPE STRING,
COITP TYPE STRING,
USGAAP TYPE STRING,
GWPROC TYPE STRING,
NGPROC TYPE STRING,
GWLCFLG TYPE STRING,
GWIEFLG TYPE STRING,
HIREXC TYPE STRING,
GWNEXC TYPE STRING,
GWAEXC TYPE STRING,
GWWEXC TYPE STRING,
GWDEXC TYPE STRING,
GWREXC TYPE STRING,
NGNEXC TYPE STRING,
NGAEXC TYPE STRING,
NGWEXC TYPE STRING,
NGDEXC TYPE STRING,
NGREXC TYPE STRING,
NEQEXC TYPE STRING,
NINVFLG TYPE STRING,
NMINFLG TYPE STRING,
HRREV TYPE STRING,
HRSHA TYPE STRING,
HRSITYP TYPE STRING,
HRAQDSI TYPE STRING,
HRDPCSI TYPE STRING,
HRDPDSI TYPE STRING,
NHSITYP TYPE STRING,
NHAQCSI TYPE STRING,
NHDPDSI TYPE STRING,
NHDPCSI TYPE STRING,
GWAYR TYPE STRING,
GWAPE TYPE STRING,
GWABG TYPE STRING,
GWARFLG TYPE STRING,
GWALFLG TYPE STRING,
GWALVAL TYPE STRING,
GWALCUR TYPE STRING,
GWAMETH TYPE STRING,
GWRYR TYPE STRING,
GWRPE TYPE STRING,
GWRBG TYPE STRING,
GWRRFLG TYPE STRING,
GWRLFLG TYPE STRING,
GWRLVAL TYPE STRING,
GWRLCUR TYPE STRING,
GWRMETH TYPE STRING,
NGAYR TYPE STRING,
NGAPE TYPE STRING,
NGABG TYPE STRING,
NGARFLG TYPE STRING,
NGALFLG TYPE STRING,
NGALVAL TYPE STRING,
NGALCUR TYPE STRING,
NGAMETH TYPE STRING,
NGRYR TYPE STRING,
NGRPE TYPE STRING,
NGRBG TYPE STRING,
NGRRFLG TYPE STRING,
NGRLFLG TYPE STRING,
NGRLVAL TYPE STRING,
NGRLCUR TYPE STRING,
NGRMETH TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TF600_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TF600_STR-MANDT sy-vline
WA_V_TF600_STR-DIMEN sy-vline
WA_V_TF600_STR-COIMETH sy-vline
WA_V_TF600_STR-CACTT sy-vline
WA_V_TF600_STR-TXT sy-vline
WA_V_TF600_STR-COITP sy-vline
WA_V_TF600_STR-USGAAP sy-vline
WA_V_TF600_STR-GWPROC sy-vline
WA_V_TF600_STR-NGPROC sy-vline
WA_V_TF600_STR-GWLCFLG sy-vline
WA_V_TF600_STR-GWIEFLG sy-vline
WA_V_TF600_STR-HIREXC sy-vline
WA_V_TF600_STR-GWNEXC sy-vline
WA_V_TF600_STR-GWAEXC sy-vline
WA_V_TF600_STR-GWWEXC sy-vline
WA_V_TF600_STR-GWDEXC sy-vline
WA_V_TF600_STR-GWREXC sy-vline
WA_V_TF600_STR-NGNEXC sy-vline
WA_V_TF600_STR-NGAEXC sy-vline
WA_V_TF600_STR-NGWEXC sy-vline
WA_V_TF600_STR-NGDEXC sy-vline
WA_V_TF600_STR-NGREXC sy-vline
WA_V_TF600_STR-NEQEXC sy-vline
WA_V_TF600_STR-NINVFLG sy-vline
WA_V_TF600_STR-NMINFLG sy-vline
WA_V_TF600_STR-HRREV sy-vline
WA_V_TF600_STR-HRSHA sy-vline
WA_V_TF600_STR-HRSITYP sy-vline
WA_V_TF600_STR-HRAQDSI sy-vline
WA_V_TF600_STR-HRDPCSI sy-vline
WA_V_TF600_STR-HRDPDSI sy-vline
WA_V_TF600_STR-NHSITYP sy-vline
WA_V_TF600_STR-NHAQCSI sy-vline
WA_V_TF600_STR-NHDPDSI sy-vline
WA_V_TF600_STR-NHDPCSI sy-vline
WA_V_TF600_STR-GWAYR sy-vline
WA_V_TF600_STR-GWAPE sy-vline
WA_V_TF600_STR-GWABG sy-vline
WA_V_TF600_STR-GWARFLG sy-vline
WA_V_TF600_STR-GWALFLG sy-vline
WA_V_TF600_STR-GWALVAL sy-vline
WA_V_TF600_STR-GWALCUR sy-vline
WA_V_TF600_STR-GWAMETH sy-vline
WA_V_TF600_STR-GWRYR sy-vline
WA_V_TF600_STR-GWRPE sy-vline
WA_V_TF600_STR-GWRBG sy-vline
WA_V_TF600_STR-GWRRFLG sy-vline
WA_V_TF600_STR-GWRLFLG sy-vline
WA_V_TF600_STR-GWRLVAL sy-vline
WA_V_TF600_STR-GWRLCUR sy-vline
WA_V_TF600_STR-GWRMETH sy-vline
WA_V_TF600_STR-NGAYR sy-vline
WA_V_TF600_STR-NGAPE sy-vline
WA_V_TF600_STR-NGABG sy-vline
WA_V_TF600_STR-NGARFLG sy-vline
WA_V_TF600_STR-NGALFLG sy-vline
WA_V_TF600_STR-NGALVAL sy-vline
WA_V_TF600_STR-NGALCUR sy-vline
WA_V_TF600_STR-NGAMETH sy-vline
WA_V_TF600_STR-NGRYR sy-vline
WA_V_TF600_STR-NGRPE sy-vline
WA_V_TF600_STR-NGRBG sy-vline
WA_V_TF600_STR-NGRRFLG sy-vline
WA_V_TF600_STR-NGRLFLG sy-vline
WA_V_TF600_STR-NGRLVAL sy-vline
WA_V_TF600_STR-NGRLCUR sy-vline
WA_V_TF600_STR-NGRMETH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.