ABAP Select data from SAP table V_TE443 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TE443 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TE443. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_TE443 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_TE443 TYPE STANDARD TABLE OF V_TE443,
      WA_V_TE443 TYPE V_TE443,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_TE443> TYPE V_TE443.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_TE443.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_TE443
  INTO TABLE IT_V_TE443.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_TE443
*  INTO TABLE @DATA(IT_V_TE4432).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_TE443 INDEX 1 INTO DATA(WA_V_TE4432).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_TE443 ASSIGNING <V_TE443>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TE443>-MANDT = 1.
<V_TE443>-BCREASON = 1.
<V_TE443>-ABP_SAVE = 1.
<V_TE443>-CHG_ABP_SAVE = 1.
<V_TE443>-ORIG_INV_UNIT = 1.
ENDLOOP.

LOOP AT IT_V_TE443 INTO WA_V_TE443.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_TE443-FIKEY_VIS, sy-vline,
WA_V_TE443-BILL_BUT_ACTIVE, sy-vline,
WA_V_TE443-PRINT_BUT_ACTIVE, sy-vline,
WA_V_TE443-PRINT_CANC_DOC, sy-vline,
WA_V_TE443-BCONTACT_VIS, sy-vline,
WA_V_TE443-REV_DUNNING, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TE443 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TE443 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TE443 INTO WA_V_TE443. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TE443_STR,
MANDT TYPE STRING,
BCREASON TYPE STRING,
ABP_SAVE TYPE STRING,
CHG_ABP_SAVE TYPE STRING,
ORIG_INV_UNIT TYPE STRING,
FIKEY_VIS TYPE STRING,
BILL_BUT_ACTIVE TYPE STRING,
PRINT_BUT_ACTIVE TYPE STRING,
PRINT_CANC_DOC TYPE STRING,
BCONTACT_VIS TYPE STRING,
REV_DUNNING TYPE STRING,
CHG_REV_DUNNING TYPE STRING,
REV_INTEREST TYPE STRING,
CHG_REV_INTEREST TYPE STRING,
MRREASON_CORR TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TE443_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TE443_STR-MANDT sy-vline
WA_V_TE443_STR-BCREASON sy-vline
WA_V_TE443_STR-ABP_SAVE sy-vline
WA_V_TE443_STR-CHG_ABP_SAVE sy-vline
WA_V_TE443_STR-ORIG_INV_UNIT sy-vline
WA_V_TE443_STR-FIKEY_VIS sy-vline
WA_V_TE443_STR-BILL_BUT_ACTIVE sy-vline
WA_V_TE443_STR-PRINT_BUT_ACTIVE sy-vline
WA_V_TE443_STR-PRINT_CANC_DOC sy-vline
WA_V_TE443_STR-BCONTACT_VIS sy-vline
WA_V_TE443_STR-REV_DUNNING sy-vline
WA_V_TE443_STR-CHG_REV_DUNNING sy-vline
WA_V_TE443_STR-REV_INTEREST sy-vline
WA_V_TE443_STR-CHG_REV_INTEREST sy-vline
WA_V_TE443_STR-MRREASON_CORR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.