ABAP Select data from SAP table V_TCO43_40 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TCO43_40 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TCO43_40. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_TCO43_40 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_TCO43_40 TYPE STANDARD TABLE OF V_TCO43_40,
      WA_V_TCO43_40 TYPE V_TCO43_40,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_TCO43_40> TYPE V_TCO43_40.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_TCO43_40.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_TCO43_40
  INTO TABLE IT_V_TCO43_40.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_TCO43_40
*  INTO TABLE @DATA(IT_V_TCO43_402).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_TCO43_40 INDEX 1 INTO DATA(WA_V_TCO43_402).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_TCO43_40 ASSIGNING <V_TCO43_40>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TCO43_40>-MANDT = 1.
<V_TCO43_40>-WERKS = 1.
<V_TCO43_40>-CO_PRODPRF = 1.
<V_TCO43_40>-FLG_REL_CR = 1.
<V_TCO43_40>-FLG_PR_REL = 1.
ENDLOOP.

LOOP AT IT_V_TCO43_40 INTO WA_V_TCO43_40.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_TCO43_40-FLG_TM_REL, sy-vline,
WA_V_TCO43_40-FLG_WM_REL, sy-vline,
WA_V_TCO43_40-PROFILE_ID, sy-vline,
WA_V_TCO43_40-AUART, sy-vline,
WA_V_TCO43_40-AUART_KDE, sy-vline,
WA_V_TCO43_40-AUART_NOM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TCO43_40 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TCO43_40 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TCO43_40 INTO WA_V_TCO43_40. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TCO43_40_STR,
MANDT TYPE STRING,
WERKS TYPE STRING,
CO_PRODPRF TYPE STRING,
FLG_REL_CR TYPE STRING,
FLG_PR_REL TYPE STRING,
FLG_TM_REL TYPE STRING,
FLG_WM_REL TYPE STRING,
PROFILE_ID TYPE STRING,
AUART TYPE STRING,
AUART_KDE TYPE STRING,
AUART_NOM TYPE STRING,
AUTYP TYPE STRING,
NAME1 TYPE STRING,
WRKTXT TYPE STRING,
PROFTXT TYPE STRING,
PRODTXT TYPE STRING,
FLG_CR_REL TYPE STRING,
CO_FLG_COM TYPE STRING,
KZBCR TYPE STRING,
KZCLA TYPE STRING,
XKCFC TYPE STRING,
WM_KZTBV TYPE STRING,
WM_KZBMG TYPE STRING,
FLG_QUAN_P TYPE STRING,
FLG_QUAN_M TYPE STRING,
FLG_KAP_TM TYPE STRING,
FLG_KAP_TB TYPE STRING,
WM_KZPGI TYPE STRING,
CFB_FLG_BBD_CALC TYPE STRING,
CFB_FLG_BBD_BTCH TYPE STRING,
SYNC_GM_FOR_EWM TYPE STRING,
HSDAT_DEF_DATE TYPE STRING,
HSDAT_DEF_OFFSET TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TCO43_40_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TCO43_40_STR-MANDT sy-vline
WA_V_TCO43_40_STR-WERKS sy-vline
WA_V_TCO43_40_STR-CO_PRODPRF sy-vline
WA_V_TCO43_40_STR-FLG_REL_CR sy-vline
WA_V_TCO43_40_STR-FLG_PR_REL sy-vline
WA_V_TCO43_40_STR-FLG_TM_REL sy-vline
WA_V_TCO43_40_STR-FLG_WM_REL sy-vline
WA_V_TCO43_40_STR-PROFILE_ID sy-vline
WA_V_TCO43_40_STR-AUART sy-vline
WA_V_TCO43_40_STR-AUART_KDE sy-vline
WA_V_TCO43_40_STR-AUART_NOM sy-vline
WA_V_TCO43_40_STR-AUTYP sy-vline
WA_V_TCO43_40_STR-NAME1 sy-vline
WA_V_TCO43_40_STR-WRKTXT sy-vline
WA_V_TCO43_40_STR-PROFTXT sy-vline
WA_V_TCO43_40_STR-PRODTXT sy-vline
WA_V_TCO43_40_STR-FLG_CR_REL sy-vline
WA_V_TCO43_40_STR-CO_FLG_COM sy-vline
WA_V_TCO43_40_STR-KZBCR sy-vline
WA_V_TCO43_40_STR-KZCLA sy-vline
WA_V_TCO43_40_STR-XKCFC sy-vline
WA_V_TCO43_40_STR-WM_KZTBV sy-vline
WA_V_TCO43_40_STR-WM_KZBMG sy-vline
WA_V_TCO43_40_STR-FLG_QUAN_P sy-vline
WA_V_TCO43_40_STR-FLG_QUAN_M sy-vline
WA_V_TCO43_40_STR-FLG_KAP_TM sy-vline
WA_V_TCO43_40_STR-FLG_KAP_TB sy-vline
WA_V_TCO43_40_STR-WM_KZPGI sy-vline
WA_V_TCO43_40_STR-CFB_FLG_BBD_CALC sy-vline
WA_V_TCO43_40_STR-CFB_FLG_BBD_BTCH sy-vline
WA_V_TCO43_40_STR-SYNC_GM_FOR_EWM sy-vline
WA_V_TCO43_40_STR-HSDAT_DEF_DATE sy-vline
WA_V_TCO43_40_STR-HSDAT_DEF_OFFSET sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.