ABAP Select data from SAP table V_TCNVZ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TCNVZ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TCNVZ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_TCNVZ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_TCNVZ TYPE STANDARD TABLE OF V_TCNVZ,
      WA_V_TCNVZ TYPE V_TCNVZ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_TCNVZ> TYPE V_TCNVZ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_TCNVZ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_TCNVZ
  INTO TABLE IT_V_TCNVZ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_TCNVZ
*  INTO TABLE @DATA(IT_V_TCNVZ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_TCNVZ INDEX 1 INTO DATA(WA_V_TCNVZ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_TCNVZ ASSIGNING <V_TCNVZ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TCNVZ>-MANDT = 1.
<V_TCNVZ>-APPLIC = 1.
<V_TCNVZ>-SUBAPP = 1.
<V_TCNVZ>-LSTVAR = 1.
<V_TCNVZ>-LINTYP = 1.
ENDLOOP.

LOOP AT IT_V_TCNVZ INTO WA_V_TCNVZ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_TCNVZ-OBJECT, sy-vline,
WA_V_TCNVZ-KTEXTO, sy-vline,
WA_V_TCNVZ-FIXPOS, sy-vline,
WA_V_TCNVZ-STDATR, sy-vline,
WA_V_TCNVZ-COLORK, sy-vline,
WA_V_TCNVZ-INTENSK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TCNVZ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TCNVZ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TCNVZ INTO WA_V_TCNVZ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TCNVZ_STR,
MANDT TYPE STRING,
APPLIC TYPE STRING,
SUBAPP TYPE STRING,
LSTVAR TYPE STRING,
LINTYP TYPE STRING,
OBJECT TYPE STRING,
KTEXTO TYPE STRING,
FIXPOS TYPE STRING,
STDATR TYPE STRING,
COLORK TYPE STRING,
INTENSK TYPE STRING,
INVERSK TYPE STRING,
COLOR TYPE STRING,
INTENS TYPE STRING,
INVERS TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TCNVZ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TCNVZ_STR-MANDT sy-vline
WA_V_TCNVZ_STR-APPLIC sy-vline
WA_V_TCNVZ_STR-SUBAPP sy-vline
WA_V_TCNVZ_STR-LSTVAR sy-vline
WA_V_TCNVZ_STR-LINTYP sy-vline
WA_V_TCNVZ_STR-OBJECT sy-vline
WA_V_TCNVZ_STR-KTEXTO sy-vline
WA_V_TCNVZ_STR-FIXPOS sy-vline
WA_V_TCNVZ_STR-STDATR sy-vline
WA_V_TCNVZ_STR-COLORK sy-vline
WA_V_TCNVZ_STR-INTENSK sy-vline
WA_V_TCNVZ_STR-INVERSK sy-vline
WA_V_TCNVZ_STR-COLOR sy-vline
WA_V_TCNVZ_STR-INTENS sy-vline
WA_V_TCNVZ_STR-INVERS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.