ABAP Select data from SAP table V_TCND into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TCND table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TCND. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_TCND table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_TCND TYPE STANDARD TABLE OF V_TCND,
      WA_V_TCND TYPE V_TCND,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_TCND> TYPE V_TCND.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_TCND.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_TCND
  INTO TABLE IT_V_TCND.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_TCND
*  INTO TABLE @DATA(IT_V_TCND2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_TCND INDEX 1 INTO DATA(WA_V_TCND2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_TCND ASSIGNING <V_TCND>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TCND>-MANDT = 1.
<V_TCND>-TABNAME = 1.
<V_TCND>-PROFID = 1.
<V_TCND>-KTEXTT = 1.
<V_TCND>-KTEXT = 1.
ENDLOOP.

LOOP AT IT_V_TCND INTO WA_V_TCND.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_TCND-AENAM, sy-vline,
WA_V_TCND-PROTECT, sy-vline,
WA_V_TCND-CUSTOM, sy-vline,
WA_V_TCND-PROF_FD, sy-vline,
WA_V_TCND-PROF_EG, sy-vline,
WA_V_TCND-PROF_SR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TCND you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TCND TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TCND INTO WA_V_TCND. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TCND_STR,
MANDT TYPE STRING,
TABNAME TYPE STRING,
PROFID TYPE STRING,
KTEXTT TYPE STRING,
KTEXT TYPE STRING,
AENAM TYPE STRING,
PROTECT TYPE STRING,
CUSTOM TYPE STRING,
PROF_FD TYPE STRING,
PROF_EG TYPE STRING,
PROF_SR TYPE STRING,
PROF_AG TYPE STRING,
PROF_GP TYPE STRING,
FLG_OTX TYPE STRING,
FLG_OTP TYPE STRING,
FLG_HIE TYPE STRING,
FLG_TREE TYPE STRING,
FLG_NAGGR TYPE STRING,
FLG_SUM_ALL TYPE STRING,
FLG_EHZ TYPE STRING,
FLG_GRP TYPE STRING,
FLG_SRA TYPE STRING,
FLG_PWT TYPE STRING,
FLG_VSV TYPE STRING,
FLG_ORG TYPE STRING,
WRT_OBJ TYPE STRING,
WRT_FLD TYPE STRING,
SELSET_FLT TYPE STRING,
SELSET_BFT TYPE STRING,
SELSET_OFT TYPE STRING,
SELID TYPE STRING,
VSCMP_ADD TYPE STRING,
VSCMP_HIE TYPE STRING,
VSCMP_ART TYPE STRING,
PROF_VGL TYPE STRING,
FLG_SHOWDEL TYPE STRING,
FLG_NOAUTH TYPE STRING,
FLG_NOPATH TYPE STRING,
SELSET_HV1 TYPE STRING,
SELSET_BH1 TYPE STRING,
SELIDH1 TYPE STRING,
VSCMP_ADD1 TYPE STRING,
VSCMP_HIE1 TYPE STRING,
VSCMP_ART1 TYPE STRING,
PROF_VGL1 TYPE STRING,
SELSET_HV2 TYPE STRING,
SELSET_BH2 TYPE STRING,
SELIDH2 TYPE STRING,
VSCMP_ADD2 TYPE STRING,
VSCMP_HIE2 TYPE STRING,
VSCMP_ART2 TYPE STRING,
PROF_VGL2 TYPE STRING,
FLG_HV_AMP TYPE STRING,
FLG_HV_AGR TYPE STRING,
SEL_FLG_IV TYPE STRING,
SEL_FLG_IP TYPE STRING,
SEL_FLG_PD TYPE STRING,
SEL_FLG_PE TYPE STRING,
SEL_FLG_PX TYPE STRING,
SEL_FLG_VB TYPE STRING,
SEL_FLG_VP TYPE STRING,
SEL_FLG_PL TYPE STRING,
SEL_FLG_AF TYPE STRING,
SEL_FLG_NZ TYPE STRING,
SEL_FLG_VW TYPE STRING,
SEL_FLG_VE TYPE STRING,
SEL_FLG_VC TYPE STRING,
SEL_FLG_EW TYPE STRING,
SEL_FLG_EE TYPE STRING,
SEL_FLG_EC TYPE STRING,
SEL_FLG_AB TYPE STRING,
SEL_FLG_MS TYPE STRING,
SEL_FLG_FH TYPE STRING,
SEL_FLG_KB TYPE STRING,
SEL_FLG_MR TYPE STRING,
SEL_FLG_RM TYPE STRING,
SEL_FLG_SO TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TCND_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TCND_STR-MANDT sy-vline
WA_V_TCND_STR-TABNAME sy-vline
WA_V_TCND_STR-PROFID sy-vline
WA_V_TCND_STR-KTEXTT sy-vline
WA_V_TCND_STR-KTEXT sy-vline
WA_V_TCND_STR-AENAM sy-vline
WA_V_TCND_STR-PROTECT sy-vline
WA_V_TCND_STR-CUSTOM sy-vline
WA_V_TCND_STR-PROF_FD sy-vline
WA_V_TCND_STR-PROF_EG sy-vline
WA_V_TCND_STR-PROF_SR sy-vline
WA_V_TCND_STR-PROF_AG sy-vline
WA_V_TCND_STR-PROF_GP sy-vline
WA_V_TCND_STR-FLG_OTX sy-vline
WA_V_TCND_STR-FLG_OTP sy-vline
WA_V_TCND_STR-FLG_HIE sy-vline
WA_V_TCND_STR-FLG_TREE sy-vline
WA_V_TCND_STR-FLG_NAGGR sy-vline
WA_V_TCND_STR-FLG_SUM_ALL sy-vline
WA_V_TCND_STR-FLG_EHZ sy-vline
WA_V_TCND_STR-FLG_GRP sy-vline
WA_V_TCND_STR-FLG_SRA sy-vline
WA_V_TCND_STR-FLG_PWT sy-vline
WA_V_TCND_STR-FLG_VSV sy-vline
WA_V_TCND_STR-FLG_ORG sy-vline
WA_V_TCND_STR-WRT_OBJ sy-vline
WA_V_TCND_STR-WRT_FLD sy-vline
WA_V_TCND_STR-SELSET_FLT sy-vline
WA_V_TCND_STR-SELSET_BFT sy-vline
WA_V_TCND_STR-SELSET_OFT sy-vline
WA_V_TCND_STR-SELID sy-vline
WA_V_TCND_STR-VSCMP_ADD sy-vline
WA_V_TCND_STR-VSCMP_HIE sy-vline
WA_V_TCND_STR-VSCMP_ART sy-vline
WA_V_TCND_STR-PROF_VGL sy-vline
WA_V_TCND_STR-FLG_SHOWDEL sy-vline
WA_V_TCND_STR-FLG_NOAUTH sy-vline
WA_V_TCND_STR-FLG_NOPATH sy-vline
WA_V_TCND_STR-SELSET_HV1 sy-vline
WA_V_TCND_STR-SELSET_BH1 sy-vline
WA_V_TCND_STR-SELIDH1 sy-vline
WA_V_TCND_STR-VSCMP_ADD1 sy-vline
WA_V_TCND_STR-VSCMP_HIE1 sy-vline
WA_V_TCND_STR-VSCMP_ART1 sy-vline
WA_V_TCND_STR-PROF_VGL1 sy-vline
WA_V_TCND_STR-SELSET_HV2 sy-vline
WA_V_TCND_STR-SELSET_BH2 sy-vline
WA_V_TCND_STR-SELIDH2 sy-vline
WA_V_TCND_STR-VSCMP_ADD2 sy-vline
WA_V_TCND_STR-VSCMP_HIE2 sy-vline
WA_V_TCND_STR-VSCMP_ART2 sy-vline
WA_V_TCND_STR-PROF_VGL2 sy-vline
WA_V_TCND_STR-FLG_HV_AMP sy-vline
WA_V_TCND_STR-FLG_HV_AGR sy-vline
WA_V_TCND_STR-SEL_FLG_IV sy-vline
WA_V_TCND_STR-SEL_FLG_IP sy-vline
WA_V_TCND_STR-SEL_FLG_PD sy-vline
WA_V_TCND_STR-SEL_FLG_PE sy-vline
WA_V_TCND_STR-SEL_FLG_PX sy-vline
WA_V_TCND_STR-SEL_FLG_VB sy-vline
WA_V_TCND_STR-SEL_FLG_VP sy-vline
WA_V_TCND_STR-SEL_FLG_PL sy-vline
WA_V_TCND_STR-SEL_FLG_AF sy-vline
WA_V_TCND_STR-SEL_FLG_NZ sy-vline
WA_V_TCND_STR-SEL_FLG_VW sy-vline
WA_V_TCND_STR-SEL_FLG_VE sy-vline
WA_V_TCND_STR-SEL_FLG_VC sy-vline
WA_V_TCND_STR-SEL_FLG_EW sy-vline
WA_V_TCND_STR-SEL_FLG_EE sy-vline
WA_V_TCND_STR-SEL_FLG_EC sy-vline
WA_V_TCND_STR-SEL_FLG_AB sy-vline
WA_V_TCND_STR-SEL_FLG_MS sy-vline
WA_V_TCND_STR-SEL_FLG_FH sy-vline
WA_V_TCND_STR-SEL_FLG_KB sy-vline
WA_V_TCND_STR-SEL_FLG_MR sy-vline
WA_V_TCND_STR-SEL_FLG_RM sy-vline
WA_V_TCND_STR-SEL_FLG_SO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.