ABAP Select data from SAP table V_TCATS_SSC_FLD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_TCATS_SSC_FLD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_TCATS_SSC_FLD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_TCATS_SSC_FLD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_TCATS_SSC_FLD TYPE STANDARD TABLE OF V_TCATS_SSC_FLD,
      WA_V_TCATS_SSC_FLD TYPE V_TCATS_SSC_FLD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_TCATS_SSC_FLD> TYPE V_TCATS_SSC_FLD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_TCATS_SSC_FLD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_TCATS_SSC_FLD
  INTO TABLE IT_V_TCATS_SSC_FLD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_TCATS_SSC_FLD
*  INTO TABLE @DATA(IT_V_TCATS_SSC_FLD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_TCATS_SSC_FLD INDEX 1 INTO DATA(WA_V_TCATS_SSC_FLD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_TCATS_SSC_FLD ASSIGNING <V_TCATS_SSC_FLD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_TCATS_SSC_FLD>-MANDT = 1.
<V_TCATS_SSC_FLD>-VARIANT = 1.
<V_TCATS_SSC_FLD>-TEXT = 1.
<V_TCATS_SSC_FLD>-MISSINGTIME = 1.
<V_TCATS_SSC_FLD>-APPROVAL = 1.
ENDLOOP.

LOOP AT IT_V_TCATS_SSC_FLD INTO WA_V_TCATS_SSC_FLD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_TCATS_SSC_FLD-NOCHANGE, sy-vline,
WA_V_TCATS_SSC_FLD-EXTMODE, sy-vline,
WA_V_TCATS_SSC_FLD-RKOSTL, sy-vline,
WA_V_TCATS_SSC_FLD-LSTAR, sy-vline,
WA_V_TCATS_SSC_FLD-RAUFNR, sy-vline,
WA_V_TCATS_SSC_FLD-RPROJ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_TCATS_SSC_FLD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_TCATS_SSC_FLD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_TCATS_SSC_FLD INTO WA_V_TCATS_SSC_FLD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_TCATS_SSC_FLD_STR,
MANDT TYPE STRING,
VARIANT TYPE STRING,
TEXT TYPE STRING,
MISSINGTIME TYPE STRING,
APPROVAL TYPE STRING,
NOCHANGE TYPE STRING,
EXTMODE TYPE STRING,
RKOSTL TYPE STRING,
LSTAR TYPE STRING,
RAUFNR TYPE STRING,
RPROJ TYPE STRING,
FREEATSAVE TYPE STRING,
MINTIMESLOT TYPE STRING,
TIMESLOTINTERVAL TYPE STRING,
WRKLOC TYPE STRING,
UNSTAFFEDPROJ TYPE STRING,
TASK TYPE STRING,
WF_APPR TYPE STRING,
WF_AUTO TYPE STRING,
OVERTIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_TCATS_SSC_FLD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_TCATS_SSC_FLD_STR-MANDT sy-vline
WA_V_TCATS_SSC_FLD_STR-VARIANT sy-vline
WA_V_TCATS_SSC_FLD_STR-TEXT sy-vline
WA_V_TCATS_SSC_FLD_STR-MISSINGTIME sy-vline
WA_V_TCATS_SSC_FLD_STR-APPROVAL sy-vline
WA_V_TCATS_SSC_FLD_STR-NOCHANGE sy-vline
WA_V_TCATS_SSC_FLD_STR-EXTMODE sy-vline
WA_V_TCATS_SSC_FLD_STR-RKOSTL sy-vline
WA_V_TCATS_SSC_FLD_STR-LSTAR sy-vline
WA_V_TCATS_SSC_FLD_STR-RAUFNR sy-vline
WA_V_TCATS_SSC_FLD_STR-RPROJ sy-vline
WA_V_TCATS_SSC_FLD_STR-FREEATSAVE sy-vline
WA_V_TCATS_SSC_FLD_STR-MINTIMESLOT sy-vline
WA_V_TCATS_SSC_FLD_STR-TIMESLOTINTERVAL sy-vline
WA_V_TCATS_SSC_FLD_STR-WRKLOC sy-vline
WA_V_TCATS_SSC_FLD_STR-UNSTAFFEDPROJ sy-vline
WA_V_TCATS_SSC_FLD_STR-TASK sy-vline
WA_V_TCATS_SSC_FLD_STR-WF_APPR sy-vline
WA_V_TCATS_SSC_FLD_STR-WF_AUTO sy-vline
WA_V_TCATS_SSC_FLD_STR-OVERTIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.