ABAP Select data from SAP table V_T852V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_T852V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_T852V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_T852V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_T852V TYPE STANDARD TABLE OF V_T852V,
      WA_V_T852V TYPE V_T852V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_T852V> TYPE V_T852V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_T852V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_T852V
  INTO TABLE IT_V_T852V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_T852V
*  INTO TABLE @DATA(IT_V_T852V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_T852V INDEX 1 INTO DATA(WA_V_T852V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_T852V ASSIGNING <V_T852V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_T852V>-MANDT = 1.
<V_T852V>-RVERS = 1.
<V_T852V>-RSUBD = 1.
<V_T852V>-RCURR = 1.
<V_T852V>-RLDNR = 1.
ENDLOOP.

LOOP AT IT_V_T852V INTO WA_V_T852V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_T852V-CHCK, sy-vline,
WA_V_T852V-CONGR, sy-vline,
WA_V_T852V-FSCAT, sy-vline,
WA_V_T852V-HLEVL, sy-vline,
WA_V_T852V-ROLLCOMP, sy-vline,
ENDLOOP. *Add any further fields from structure WA_V_T852V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_T852V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_T852V INTO WA_V_T852V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T852V-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T852V-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T852V-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T852V-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ROLLCOMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T852V-ROLLCOMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T852V-ROLLCOMP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_T852V_STR,
MANDT TYPE STRING,
RVERS TYPE STRING,
RSUBD TYPE STRING,
RCURR TYPE STRING,
RLDNR TYPE STRING,
CHCK TYPE STRING,
CONGR TYPE STRING,
FSCAT TYPE STRING,
HLEVL TYPE STRING,
ROLLCOMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_T852V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_T852V_STR-MANDT sy-vline
WA_V_T852V_STR-RVERS sy-vline
WA_V_T852V_STR-RSUBD sy-vline
WA_V_T852V_STR-RCURR sy-vline
WA_V_T852V_STR-RLDNR sy-vline
WA_V_T852V_STR-CHCK sy-vline
WA_V_T852V_STR-CONGR sy-vline
WA_V_T852V_STR-FSCAT sy-vline
WA_V_T852V_STR-HLEVL sy-vline
WA_V_T852V_STR-ROLLCOMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.