ABAP Select data from SAP table V_T7PIQHSCHECK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_T7PIQHSCHECK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_T7PIQHSCHECK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_T7PIQHSCHECK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_T7PIQHSCHECK TYPE STANDARD TABLE OF V_T7PIQHSCHECK,
      WA_V_T7PIQHSCHECK TYPE V_T7PIQHSCHECK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_T7PIQHSCHECK> TYPE V_T7PIQHSCHECK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_T7PIQHSCHECK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_T7PIQHSCHECK
  INTO TABLE IT_V_T7PIQHSCHECK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_T7PIQHSCHECK
*  INTO TABLE @DATA(IT_V_T7PIQHSCHECK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_T7PIQHSCHECK INDEX 1 INTO DATA(WA_V_T7PIQHSCHECK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_T7PIQHSCHECK ASSIGNING <V_T7PIQHSCHECK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_T7PIQHSCHECK>-MANDT = 1.
<V_T7PIQHSCHECK>-TIMEPOINT = 1.
<V_T7PIQHSCHECK>-HS_STATUS = 1.
<V_T7PIQHSCHECK>-ACTIVITY = 1.
<V_T7PIQHSCHECK>-TIMEPOINTTEXT = 1.
ENDLOOP.

LOOP AT IT_V_T7PIQHSCHECK INTO WA_V_T7PIQHSCHECK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_T7PIQHSCHECK-SUTXT, sy-vline,
WA_V_T7PIQHSCHECK-HS_INACT_FLAG, sy-vline,
WA_V_T7PIQHSCHECK-MSGTY, sy-vline,
WA_V_T7PIQHSCHECK-ARBGB, sy-vline,
WA_V_T7PIQHSCHECK-MSGNR, sy-vline,
WA_V_T7PIQHSCHECK-MSGV1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_T7PIQHSCHECK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_T7PIQHSCHECK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_T7PIQHSCHECK INTO WA_V_T7PIQHSCHECK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_T7PIQHSCHECK_STR,
MANDT TYPE STRING,
TIMEPOINT TYPE STRING,
HS_STATUS TYPE STRING,
ACTIVITY TYPE STRING,
TIMEPOINTTEXT TYPE STRING,
SUTXT TYPE STRING,
HS_INACT_FLAG TYPE STRING,
MSGTY TYPE STRING,
ARBGB TYPE STRING,
MSGNR TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,
STEXT TYPE STRING,
TEXT TYPE STRING,
PROCESST TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_T7PIQHSCHECK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_T7PIQHSCHECK_STR-MANDT sy-vline
WA_V_T7PIQHSCHECK_STR-TIMEPOINT sy-vline
WA_V_T7PIQHSCHECK_STR-HS_STATUS sy-vline
WA_V_T7PIQHSCHECK_STR-ACTIVITY sy-vline
WA_V_T7PIQHSCHECK_STR-TIMEPOINTTEXT sy-vline
WA_V_T7PIQHSCHECK_STR-SUTXT sy-vline
WA_V_T7PIQHSCHECK_STR-HS_INACT_FLAG sy-vline
WA_V_T7PIQHSCHECK_STR-MSGTY sy-vline
WA_V_T7PIQHSCHECK_STR-ARBGB sy-vline
WA_V_T7PIQHSCHECK_STR-MSGNR sy-vline
WA_V_T7PIQHSCHECK_STR-MSGV1 sy-vline
WA_V_T7PIQHSCHECK_STR-MSGV2 sy-vline
WA_V_T7PIQHSCHECK_STR-MSGV3 sy-vline
WA_V_T7PIQHSCHECK_STR-MSGV4 sy-vline
WA_V_T7PIQHSCHECK_STR-STEXT sy-vline
WA_V_T7PIQHSCHECK_STR-TEXT sy-vline
WA_V_T7PIQHSCHECK_STR-PROCESST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.