ABAP Select data from SAP table V_T74FW into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_T74FW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_T74FW. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_T74FW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_T74FW TYPE STANDARD TABLE OF V_T74FW,
      WA_V_T74FW TYPE V_T74FW,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_T74FW> TYPE V_T74FW.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_T74FW.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_T74FW
  INTO TABLE IT_V_T74FW.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_T74FW
*  INTO TABLE @DATA(IT_V_T74FW2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_T74FW INDEX 1 INTO DATA(WA_V_T74FW2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_T74FW ASSIGNING <V_T74FW>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_T74FW>-MANDT = 1.
<V_T74FW>-BAREA = 1.
<V_T74FW>-BPLAN = 1.
<V_T74FW>-CCNLM = 1.
<V_T74FW>-CCNAM = 1.
ENDLOOP.

LOOP AT IT_V_T74FW INTO WA_V_T74FW.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_T74FW-CURRE, sy-vline,
WA_V_T74FW-CCNFA, sy-vline,
WA_V_T74FW-CCNWT, sy-vline,
WA_V_T74FW-CCNRL, sy-vline,
WA_V_T74FW-CCNRN, sy-vline,
WA_V_T74FW-BSALM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_T74FW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_T74FW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_T74FW INTO WA_V_T74FW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_T74FW_STR,
MANDT TYPE STRING,
BAREA TYPE STRING,
BPLAN TYPE STRING,
CCNLM TYPE STRING,
CCNAM TYPE STRING,
CURRE TYPE STRING,
CCNFA TYPE STRING,
CCNWT TYPE STRING,
CCNRL TYPE STRING,
CCNRN TYPE STRING,
BSALM TYPE STRING,
BSALD TYPE STRING,
RELOP TYPE STRING,
PERIO TYPE STRING,
LTEXT TYPE STRING,
PLNTX TYPE STRING,
BPCAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_T74FW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_T74FW_STR-MANDT sy-vline
WA_V_T74FW_STR-BAREA sy-vline
WA_V_T74FW_STR-BPLAN sy-vline
WA_V_T74FW_STR-CCNLM sy-vline
WA_V_T74FW_STR-CCNAM sy-vline
WA_V_T74FW_STR-CURRE sy-vline
WA_V_T74FW_STR-CCNFA sy-vline
WA_V_T74FW_STR-CCNWT sy-vline
WA_V_T74FW_STR-CCNRL sy-vline
WA_V_T74FW_STR-CCNRN sy-vline
WA_V_T74FW_STR-BSALM sy-vline
WA_V_T74FW_STR-BSALD sy-vline
WA_V_T74FW_STR-RELOP sy-vline
WA_V_T74FW_STR-PERIO sy-vline
WA_V_T74FW_STR-LTEXT sy-vline
WA_V_T74FW_STR-PLNTX sy-vline
WA_V_T74FW_STR-BPCAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.