ABAP Select data from SAP table V_T5CEJ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_T5CEJ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_T5CEJ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_T5CEJ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_T5CEJ TYPE STANDARD TABLE OF V_T5CEJ,
      WA_V_T5CEJ TYPE V_T5CEJ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_T5CEJ> TYPE V_T5CEJ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_T5CEJ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_T5CEJ
  INTO TABLE IT_V_T5CEJ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_T5CEJ
*  INTO TABLE @DATA(IT_V_T5CEJ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_T5CEJ INDEX 1 INTO DATA(WA_V_T5CEJ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_T5CEJ ASSIGNING <V_T5CEJ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_T5CEJ>-MANDT = 1.
<V_T5CEJ>-MOLGA = 1.
<V_T5CEJ>-STAMM = 1.
<V_T5CEJ>-INFTY = 1.
<V_T5CEJ>-SUBTY = 1.
ENDLOOP.

LOOP AT IT_V_T5CEJ INTO WA_V_T5CEJ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_T5CEJ-FNAME, sy-vline,
WA_V_T5CEJ-SNAME, sy-vline,
WA_V_T5CEJ-ELEMN, sy-vline,
WA_V_T5CEJ-LTEXT_MOLGA, sy-vline,
WA_V_T5CEJ-LTEXT_STAMM, sy-vline,
ENDLOOP. *Add any further fields from structure WA_V_T5CEJ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_T5CEJ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_T5CEJ INTO WA_V_T5CEJ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_T5CEJ_STR,
MANDT TYPE STRING,
MOLGA TYPE STRING,
STAMM TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
FNAME TYPE STRING,
SNAME TYPE STRING,
ELEMN TYPE STRING,
LTEXT_MOLGA TYPE STRING,
LTEXT_STAMM TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_T5CEJ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_T5CEJ_STR-MANDT sy-vline
WA_V_T5CEJ_STR-MOLGA sy-vline
WA_V_T5CEJ_STR-STAMM sy-vline
WA_V_T5CEJ_STR-INFTY sy-vline
WA_V_T5CEJ_STR-SUBTY sy-vline
WA_V_T5CEJ_STR-FNAME sy-vline
WA_V_T5CEJ_STR-SNAME sy-vline
WA_V_T5CEJ_STR-ELEMN sy-vline
WA_V_T5CEJ_STR-LTEXT_MOLGA sy-vline
WA_V_T5CEJ_STR-LTEXT_STAMM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.