ABAP Select data from SAP table V_T030HB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_T030HB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_T030HB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_T030HB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_T030HB TYPE STANDARD TABLE OF V_T030HB,
      WA_V_T030HB TYPE V_T030HB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_T030HB> TYPE V_T030HB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_T030HB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_T030HB
  INTO TABLE IT_V_T030HB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_T030HB
*  INTO TABLE @DATA(IT_V_T030HB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_T030HB INDEX 1 INTO DATA(WA_V_T030HB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_T030HB ASSIGNING <V_T030HB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_T030HB>-MANDT = 1.
<V_T030HB>-KTOPL = 1.
<V_T030HB>-BWBER = 1.
<V_T030HB>-HKONT = 1.
<V_T030HB>-WAERS = 1.
ENDLOOP.

LOOP AT IT_V_T030HB INTO WA_V_T030HB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_T030HB-LKORR, sy-vline,
WA_V_T030HB-LSBEW, sy-vline,
WA_V_T030HB-LHBEW, sy-vline,
WA_V_T030HB-LSREA, sy-vline,
WA_V_T030HB-LHREA, sy-vline,
WA_V_T030HB-LSTRA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_T030HB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_T030HB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_T030HB INTO WA_V_T030HB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field HKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T030HB-HKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T030HB-HKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LKORR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T030HB-LKORR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T030HB-LKORR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LSBEW CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T030HB-LSBEW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T030HB-LSBEW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LHBEW CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T030HB-LHBEW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T030HB-LHBEW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LSREA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T030HB-LSREA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T030HB-LSREA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LHREA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T030HB-LHREA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T030HB-LHREA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LSTRA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T030HB-LSTRA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T030HB-LSTRA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LHTRA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T030HB-LHTRA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T030HB-LHTRA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LSTRV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T030HB-LSTRV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T030HB-LSTRV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LHTRV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_T030HB-LHTRV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_T030HB-LHTRV.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_T030HB_STR,
MANDT TYPE STRING,
KTOPL TYPE STRING,
BWBER TYPE STRING,
HKONT TYPE STRING,
WAERS TYPE STRING,
LKORR TYPE STRING,
LSBEW TYPE STRING,
LHBEW TYPE STRING,
LSREA TYPE STRING,
LHREA TYPE STRING,
LSTRA TYPE STRING,
LHTRA TYPE STRING,
LSTRV TYPE STRING,
LHTRV TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_T030HB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_T030HB_STR-MANDT sy-vline
WA_V_T030HB_STR-KTOPL sy-vline
WA_V_T030HB_STR-BWBER sy-vline
WA_V_T030HB_STR-HKONT sy-vline
WA_V_T030HB_STR-WAERS sy-vline
WA_V_T030HB_STR-LKORR sy-vline
WA_V_T030HB_STR-LSBEW sy-vline
WA_V_T030HB_STR-LHBEW sy-vline
WA_V_T030HB_STR-LSREA sy-vline
WA_V_T030HB_STR-LHREA sy-vline
WA_V_T030HB_STR-LSTRA sy-vline
WA_V_T030HB_STR-LHTRA sy-vline
WA_V_T030HB_STR-LSTRV sy-vline
WA_V_T030HB_STR-LHTRV sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.