ABAP Select data from SAP table V_SCMI_ACT_LOG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_SCMI_ACT_LOG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_SCMI_ACT_LOG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_SCMI_ACT_LOG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_SCMI_ACT_LOG TYPE STANDARD TABLE OF V_SCMI_ACT_LOG,
      WA_V_SCMI_ACT_LOG TYPE V_SCMI_ACT_LOG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_SCMI_ACT_LOG> TYPE V_SCMI_ACT_LOG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_SCMI_ACT_LOG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_SCMI_ACT_LOG
  INTO TABLE IT_V_SCMI_ACT_LOG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_SCMI_ACT_LOG
*  INTO TABLE @DATA(IT_V_SCMI_ACT_LOG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_SCMI_ACT_LOG INDEX 1 INTO DATA(WA_V_SCMI_ACT_LOG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_SCMI_ACT_LOG ASSIGNING <V_SCMI_ACT_LOG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_SCMI_ACT_LOG>-CLIENT = 1.
<V_SCMI_ACT_LOG>-IDENTIFIER = 1.
<V_SCMI_ACT_LOG>-ACTIVITY_TYPE = 1.
<V_SCMI_ACT_LOG>-ACTIVITY_ID = 1.
<V_SCMI_ACT_LOG>-CLASSNAME = 1.
ENDLOOP.

LOOP AT IT_V_SCMI_ACT_LOG INTO WA_V_SCMI_ACT_LOG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_SCMI_ACT_LOG-VIEWCLUSTER, sy-vline,
WA_V_SCMI_ACT_LOG-VIEWNAME, sy-vline,
WA_V_SCMI_ACT_LOG-TABLENAME, sy-vline,
WA_V_SCMI_ACT_LOG-TRKEY, sy-vline,
WA_V_SCMI_ACT_LOG-FIELDNAME, sy-vline,
WA_V_SCMI_ACT_LOG-FIELDVALUE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_SCMI_ACT_LOG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_SCMI_ACT_LOG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_SCMI_ACT_LOG INTO WA_V_SCMI_ACT_LOG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_SCMI_ACT_LOG_STR,
CLIENT TYPE STRING,
IDENTIFIER TYPE STRING,
ACTIVITY_TYPE TYPE STRING,
ACTIVITY_ID TYPE STRING,
CLASSNAME TYPE STRING,
VIEWCLUSTER TYPE STRING,
VIEWNAME TYPE STRING,
TABLENAME TYPE STRING,
TRKEY TYPE STRING,
FIELDNAME TYPE STRING,
FIELDVALUE TYPE STRING,
STATUS TYPE STRING,
ADDITIONALDTLS TYPE STRING,
IMG_ACTIVITY TYPE STRING,
OBJECT_TYPE TYPE STRING,
LOG_ID TYPE STRING,
SEQUENCE TYPE STRING,
MSG_COUNTER TYPE STRING,
ACTIVATION_PHASE TYPE STRING,
TYPE TYPE STRING,
ID TYPE STRING,
MSG_NUMBER TYPE STRING,
MESSAGE TYPE STRING,
MESSAGE_V1 TYPE STRING,
MESSAGE_V2 TYPE STRING,
MESSAGE_V3 TYPE STRING,
MESSAGE_V4 TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_SCMI_ACT_LOG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_SCMI_ACT_LOG_STR-CLIENT sy-vline
WA_V_SCMI_ACT_LOG_STR-IDENTIFIER sy-vline
WA_V_SCMI_ACT_LOG_STR-ACTIVITY_TYPE sy-vline
WA_V_SCMI_ACT_LOG_STR-ACTIVITY_ID sy-vline
WA_V_SCMI_ACT_LOG_STR-CLASSNAME sy-vline
WA_V_SCMI_ACT_LOG_STR-VIEWCLUSTER sy-vline
WA_V_SCMI_ACT_LOG_STR-VIEWNAME sy-vline
WA_V_SCMI_ACT_LOG_STR-TABLENAME sy-vline
WA_V_SCMI_ACT_LOG_STR-TRKEY sy-vline
WA_V_SCMI_ACT_LOG_STR-FIELDNAME sy-vline
WA_V_SCMI_ACT_LOG_STR-FIELDVALUE sy-vline
WA_V_SCMI_ACT_LOG_STR-STATUS sy-vline
WA_V_SCMI_ACT_LOG_STR-ADDITIONALDTLS sy-vline
WA_V_SCMI_ACT_LOG_STR-IMG_ACTIVITY sy-vline
WA_V_SCMI_ACT_LOG_STR-OBJECT_TYPE sy-vline
WA_V_SCMI_ACT_LOG_STR-LOG_ID sy-vline
WA_V_SCMI_ACT_LOG_STR-SEQUENCE sy-vline
WA_V_SCMI_ACT_LOG_STR-MSG_COUNTER sy-vline
WA_V_SCMI_ACT_LOG_STR-ACTIVATION_PHASE sy-vline
WA_V_SCMI_ACT_LOG_STR-TYPE sy-vline
WA_V_SCMI_ACT_LOG_STR-ID sy-vline
WA_V_SCMI_ACT_LOG_STR-MSG_NUMBER sy-vline
WA_V_SCMI_ACT_LOG_STR-MESSAGE sy-vline
WA_V_SCMI_ACT_LOG_STR-MESSAGE_V1 sy-vline
WA_V_SCMI_ACT_LOG_STR-MESSAGE_V2 sy-vline
WA_V_SCMI_ACT_LOG_STR-MESSAGE_V3 sy-vline
WA_V_SCMI_ACT_LOG_STR-MESSAGE_V4 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.