ABAP Select data from SAP table V_RMXTT_Q10D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_RMXTT_Q10D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_RMXTT_Q10D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_RMXTT_Q10D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_RMXTT_Q10D TYPE STANDARD TABLE OF V_RMXTT_Q10D,
      WA_V_RMXTT_Q10D TYPE V_RMXTT_Q10D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_RMXTT_Q10D> TYPE V_RMXTT_Q10D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_RMXTT_Q10D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_RMXTT_Q10D
  INTO TABLE IT_V_RMXTT_Q10D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_RMXTT_Q10D
*  INTO TABLE @DATA(IT_V_RMXTT_Q10D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_RMXTT_Q10D INDEX 1 INTO DATA(WA_V_RMXTT_Q10D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_RMXTT_Q10D ASSIGNING <V_RMXTT_Q10D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_RMXTT_Q10D>-MANDT = 1.
<V_RMXTT_Q10D>-PLANT = 1.
<V_RMXTT_Q10D>-BBID = 1.
<V_RMXTT_Q10D>-QPRIMPACK = 1.
<V_RMXTT_Q10D>-PRIMPACKTXT = 1.
ENDLOOP.

LOOP AT IT_V_RMXTT_Q10D INTO WA_V_RMXTT_Q10D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_RMXTT_Q10D-STRAT, sy-vline,
WA_V_RMXTT_Q10D-KTEXT, sy-vline,
WA_V_RMXTT_Q10D-TXT, sy-vline,
WA_V_RMXTT_Q10D-QMART, sy-vline,
WA_V_RMXTT_Q10D-QMARTX, sy-vline,
WA_V_RMXTT_Q10D-ADM_CREA_BY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_RMXTT_Q10D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_RMXTT_Q10D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_RMXTT_Q10D INTO WA_V_RMXTT_Q10D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_RMXTT_Q10D_STR,
MANDT TYPE STRING,
PLANT TYPE STRING,
BBID TYPE STRING,
QPRIMPACK TYPE STRING,
PRIMPACKTXT TYPE STRING,
STRAT TYPE STRING,
KTEXT TYPE STRING,
TXT TYPE STRING,
QMART TYPE STRING,
QMARTX TYPE STRING,
ADM_CREA_BY TYPE STRING,
ADM_CREA_AT TYPE STRING,
ADM_CHG_BY TYPE STRING,
ADM_CHG_AT TYPE STRING,
DEP TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_RMXTT_Q10D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_RMXTT_Q10D_STR-MANDT sy-vline
WA_V_RMXTT_Q10D_STR-PLANT sy-vline
WA_V_RMXTT_Q10D_STR-BBID sy-vline
WA_V_RMXTT_Q10D_STR-QPRIMPACK sy-vline
WA_V_RMXTT_Q10D_STR-PRIMPACKTXT sy-vline
WA_V_RMXTT_Q10D_STR-STRAT sy-vline
WA_V_RMXTT_Q10D_STR-KTEXT sy-vline
WA_V_RMXTT_Q10D_STR-TXT sy-vline
WA_V_RMXTT_Q10D_STR-QMART sy-vline
WA_V_RMXTT_Q10D_STR-QMARTX sy-vline
WA_V_RMXTT_Q10D_STR-ADM_CREA_BY sy-vline
WA_V_RMXTT_Q10D_STR-ADM_CREA_AT sy-vline
WA_V_RMXTT_Q10D_STR-ADM_CHG_BY sy-vline
WA_V_RMXTT_Q10D_STR-ADM_CHG_AT sy-vline
WA_V_RMXTT_Q10D_STR-DEP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.