ABAP Select data from SAP table V_RCPR_WADD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_RCPR_WADD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_RCPR_WADD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_RCPR_WADD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_RCPR_WADD TYPE STANDARD TABLE OF V_RCPR_WADD,
      WA_V_RCPR_WADD TYPE V_RCPR_WADD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_RCPR_WADD> TYPE V_RCPR_WADD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_RCPR_WADD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_RCPR_WADD
  INTO TABLE IT_V_RCPR_WADD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_RCPR_WADD
*  INTO TABLE @DATA(IT_V_RCPR_WADD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_RCPR_WADD INDEX 1 INTO DATA(WA_V_RCPR_WADD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_RCPR_WADD ASSIGNING <V_RCPR_WADD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_RCPR_WADD>-MANDT = 1.
<V_RCPR_WADD>-CPROF = 1.
<V_RCPR_WADD>-CPRTEXT = 1.
<V_RCPR_WADD>-RVALU = 1.
<V_RCPR_WADD>-RDYNA = 1.
ENDLOOP.

LOOP AT IT_V_RCPR_WADD INTO WA_V_RCPR_WADD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_RCPR_WADD-RSTAT, sy-vline,
WA_V_RCPR_WADD-RMAMI, sy-vline,
WA_V_RCPR_WADD-RCHALUM, sy-vline,
WA_V_RCPR_WADD-RVALDEC, sy-vline,
WA_V_RCPR_WADD-PURPAR, sy-vline,
WA_V_RCPR_WADD-RLEAVE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_RCPR_WADD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_RCPR_WADD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_RCPR_WADD INTO WA_V_RCPR_WADD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_RCPR_WADD_STR,
MANDT TYPE STRING,
CPROF TYPE STRING,
CPRTEXT TYPE STRING,
RVALU TYPE STRING,
RDYNA TYPE STRING,
RSTAT TYPE STRING,
RMAMI TYPE STRING,
RCHALUM TYPE STRING,
RVALDEC TYPE STRING,
PURPAR TYPE STRING,
RLEAVE TYPE STRING,
RAUFAB TYPE STRING,
RMUFSD_WADDON TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_RCPR_WADD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_RCPR_WADD_STR-MANDT sy-vline
WA_V_RCPR_WADD_STR-CPROF sy-vline
WA_V_RCPR_WADD_STR-CPRTEXT sy-vline
WA_V_RCPR_WADD_STR-RVALU sy-vline
WA_V_RCPR_WADD_STR-RDYNA sy-vline
WA_V_RCPR_WADD_STR-RSTAT sy-vline
WA_V_RCPR_WADD_STR-RMAMI sy-vline
WA_V_RCPR_WADD_STR-RCHALUM sy-vline
WA_V_RCPR_WADD_STR-RVALDEC sy-vline
WA_V_RCPR_WADD_STR-PURPAR sy-vline
WA_V_RCPR_WADD_STR-RLEAVE sy-vline
WA_V_RCPR_WADD_STR-RAUFAB sy-vline
WA_V_RCPR_WADD_STR-RMUFSD_WADDON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.