ABAP Select data from SAP table V_OIRA_PRNFLDS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_OIRA_PRNFLDS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_OIRA_PRNFLDS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_OIRA_PRNFLDS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_OIRA_PRNFLDS TYPE STANDARD TABLE OF V_OIRA_PRNFLDS,
      WA_V_OIRA_PRNFLDS TYPE V_OIRA_PRNFLDS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_OIRA_PRNFLDS> TYPE V_OIRA_PRNFLDS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_OIRA_PRNFLDS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_OIRA_PRNFLDS
  INTO TABLE IT_V_OIRA_PRNFLDS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_OIRA_PRNFLDS
*  INTO TABLE @DATA(IT_V_OIRA_PRNFLDS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_OIRA_PRNFLDS INDEX 1 INTO DATA(WA_V_OIRA_PRNFLDS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_OIRA_PRNFLDS ASSIGNING <V_OIRA_PRNFLDS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_OIRA_PRNFLDS>-MANDT = 1.
<V_OIRA_PRNFLDS>-PRINTPROC = 1.
<V_OIRA_PRNFLDS>-PRNTYPGP = 1.
<V_OIRA_PRNFLDS>-PRINTCALL = 1.
<V_OIRA_PRNFLDS>-DESTFLD = 1.
ENDLOOP.

LOOP AT IT_V_OIRA_PRNFLDS INTO WA_V_OIRA_PRNFLDS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_OIRA_PRNFLDS-SRCTAB, sy-vline,
WA_V_OIRA_PRNFLDS-SRCFLD, sy-vline,
WA_V_OIRA_PRNFLDS-CONST, sy-vline,
WA_V_OIRA_PRNFLDS-SRCBADI, sy-vline,
WA_V_OIRA_PRNFLDS-INTEXT, sy-vline,
WA_V_OIRA_PRNFLDS-PROCDESCR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_OIRA_PRNFLDS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_OIRA_PRNFLDS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_OIRA_PRNFLDS INTO WA_V_OIRA_PRNFLDS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_OIRA_PRNFLDS_STR,
MANDT TYPE STRING,
PRINTPROC TYPE STRING,
PRNTYPGP TYPE STRING,
PRINTCALL TYPE STRING,
DESTFLD TYPE STRING,
SRCTAB TYPE STRING,
SRCFLD TYPE STRING,
CONST TYPE STRING,
SRCBADI TYPE STRING,
INTEXT TYPE STRING,
PROCDESCR TYPE STRING,
CALLDESCR TYPE STRING,
TYPDESCR TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_OIRA_PRNFLDS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_OIRA_PRNFLDS_STR-MANDT sy-vline
WA_V_OIRA_PRNFLDS_STR-PRINTPROC sy-vline
WA_V_OIRA_PRNFLDS_STR-PRNTYPGP sy-vline
WA_V_OIRA_PRNFLDS_STR-PRINTCALL sy-vline
WA_V_OIRA_PRNFLDS_STR-DESTFLD sy-vline
WA_V_OIRA_PRNFLDS_STR-SRCTAB sy-vline
WA_V_OIRA_PRNFLDS_STR-SRCFLD sy-vline
WA_V_OIRA_PRNFLDS_STR-CONST sy-vline
WA_V_OIRA_PRNFLDS_STR-SRCBADI sy-vline
WA_V_OIRA_PRNFLDS_STR-INTEXT sy-vline
WA_V_OIRA_PRNFLDS_STR-PROCDESCR sy-vline
WA_V_OIRA_PRNFLDS_STR-CALLDESCR sy-vline
WA_V_OIRA_PRNFLDS_STR-TYPDESCR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.