ABAP Select data from SAP table V_OIJNOMI_LDS_BS into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_OIJNOMI_LDS_BS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_OIJNOMI_LDS_BS. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the V_OIJNOMI_LDS_BS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_V_OIJNOMI_LDS_BS TYPE STANDARD TABLE OF V_OIJNOMI_LDS_BS, WA_V_OIJNOMI_LDS_BS TYPE V_OIJNOMI_LDS_BS, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <V_OIJNOMI_LDS_BS> TYPE V_OIJNOMI_LDS_BS. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_V_OIJNOMI_LDS_BS. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM V_OIJNOMI_LDS_BS INTO TABLE IT_V_OIJNOMI_LDS_BS. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM V_OIJNOMI_LDS_BS * INTO TABLE @DATA(IT_V_OIJNOMI_LDS_BS2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_V_OIJNOMI_LDS_BS INDEX 1 INTO DATA(WA_V_OIJNOMI_LDS_BS2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_V_OIJNOMI_LDS_BS ASSIGNING <V_OIJNOMI_LDS_BS>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_OIJNOMI_LDS_BS>-MANDT = 1.
<V_OIJNOMI_LDS_BS>-PEGTYPE = 1.
<V_OIJNOMI_LDS_BS>-PEGID = 1.
<V_OIJNOMI_LDS_BS>-BRTHSEQ = 1.
<V_OIJNOMI_LDS_BS>-NOMTK = 1.
ENDLOOP. LOOP AT IT_V_OIJNOMI_LDS_BS INTO WA_V_OIJNOMI_LDS_BS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_V_OIJNOMI_LDS_BS-SHIPLDSEQ, sy-vline,
WA_V_OIJNOMI_LDS_BS-SCHEDMAT, sy-vline,
WA_V_OIJNOMI_LDS_BS-LDMAT, sy-vline,
WA_V_OIJNOMI_LDS_BS-LDQUAN, sy-vline,
WA_V_OIJNOMI_LDS_BS-LDUOM, sy-vline,
WA_V_OIJNOMI_LDS_BS-ACTUALQTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_OIJNOMI_LDS_BS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_OIJNOMI_LDS_BS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_OIJNOMI_LDS_BS INTO WA_V_OIJNOMI_LDS_BS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field PEGID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-PEGID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-PEGID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field NOMTK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-NOMTK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-NOMTK.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field SCHEDMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-SCHEDMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-SCHEDMAT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field LDMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-LDMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-LDMAT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field LDUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-LDUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-LDUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ACTUALUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-ACTUALUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-ACTUALUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field BERID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-BERID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-BERID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LIGHTLOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-LIGHTLOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-LIGHTLOC.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LIGHTVESSEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-LIGHTVESSEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-LIGHTVESSEL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LIGHTNOM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-LIGHTNOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-LIGHTNOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field TARGETQTYUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-TARGETQTYUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-TARGETQTYUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field METERNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-METERNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-METERNO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ENDGAUGEUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-ENDGAUGEUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-ENDGAUGEUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field DRAFTUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-DRAFTUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-DRAFTUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field DEADWGTUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-DEADWGTUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-DEADWGTUOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TICKETNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_OIJNOMI_LDS_BS-TICKETNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_OIJNOMI_LDS_BS-TICKETNO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_OIJNOMI_LDS_BS_STR,
MANDT TYPE STRING,
PEGTYPE TYPE STRING,
PEGID TYPE STRING,
BRTHSEQ TYPE STRING,
NOMTK TYPE STRING,
SHIPLDSEQ TYPE STRING,
SCHEDMAT TYPE STRING,
LDMAT TYPE STRING,
LDQUAN TYPE STRING,
LDUOM TYPE STRING,
ACTUALQTY TYPE STRING,
ACTUALUOM TYPE STRING,
BERID TYPE STRING,
TANKID TYPE STRING,
LIGHTLOC TYPE STRING,
LIGHTVESSEL TYPE STRING,
LIGHTNOM TYPE STRING,
LDFRDATE TYPE STRING,
LDFRTIME TYPE STRING,
LDTODATE TYPE STRING,
LDTOTIME TYPE STRING,
LDSYSTID TYPE STRING,
TARGETQTY TYPE STRING,
TARGETQTYUOM TYPE STRING,
METERNO TYPE STRING,
STMETER TYPE STRING,
ENDMETER TYPE STRING,
DIPDATE TYPE STRING,
DIPTIME TYPE STRING,
ENDGAUGEVAL TYPE STRING,
ENDGAUGEUOM TYPE STRING,
VSL_ARRDRAFT TYPE STRING,
VSL_DEPDRAFT TYPE STRING,
DRAFTUOM TYPE STRING,
VSL_TXDEADWGT TYPE STRING,
DEADWGTUOM TYPE STRING,
TICKETNO TYPE STRING,
FLUSHFLAG TYPE STRING,
LDIND TYPE STRING,
LIGHTNOMIT TYPE STRING,
SCHED_TST_FROM TYPE STRING,
SCHED_TST_TO TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_OIJNOMI_LDS_BS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_OIJNOMI_LDS_BS_STR-MANDT sy-vline
WA_V_OIJNOMI_LDS_BS_STR-PEGTYPE sy-vline
WA_V_OIJNOMI_LDS_BS_STR-PEGID sy-vline
WA_V_OIJNOMI_LDS_BS_STR-BRTHSEQ sy-vline
WA_V_OIJNOMI_LDS_BS_STR-NOMTK sy-vline
WA_V_OIJNOMI_LDS_BS_STR-SHIPLDSEQ sy-vline
WA_V_OIJNOMI_LDS_BS_STR-SCHEDMAT sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LDMAT sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LDQUAN sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LDUOM sy-vline
WA_V_OIJNOMI_LDS_BS_STR-ACTUALQTY sy-vline
WA_V_OIJNOMI_LDS_BS_STR-ACTUALUOM sy-vline
WA_V_OIJNOMI_LDS_BS_STR-BERID sy-vline
WA_V_OIJNOMI_LDS_BS_STR-TANKID sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LIGHTLOC sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LIGHTVESSEL sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LIGHTNOM sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LDFRDATE sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LDFRTIME sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LDTODATE sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LDTOTIME sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LDSYSTID sy-vline
WA_V_OIJNOMI_LDS_BS_STR-TARGETQTY sy-vline
WA_V_OIJNOMI_LDS_BS_STR-TARGETQTYUOM sy-vline
WA_V_OIJNOMI_LDS_BS_STR-METERNO sy-vline
WA_V_OIJNOMI_LDS_BS_STR-STMETER sy-vline
WA_V_OIJNOMI_LDS_BS_STR-ENDMETER sy-vline
WA_V_OIJNOMI_LDS_BS_STR-DIPDATE sy-vline
WA_V_OIJNOMI_LDS_BS_STR-DIPTIME sy-vline
WA_V_OIJNOMI_LDS_BS_STR-ENDGAUGEVAL sy-vline
WA_V_OIJNOMI_LDS_BS_STR-ENDGAUGEUOM sy-vline
WA_V_OIJNOMI_LDS_BS_STR-VSL_ARRDRAFT sy-vline
WA_V_OIJNOMI_LDS_BS_STR-VSL_DEPDRAFT sy-vline
WA_V_OIJNOMI_LDS_BS_STR-DRAFTUOM sy-vline
WA_V_OIJNOMI_LDS_BS_STR-VSL_TXDEADWGT sy-vline
WA_V_OIJNOMI_LDS_BS_STR-DEADWGTUOM sy-vline
WA_V_OIJNOMI_LDS_BS_STR-TICKETNO sy-vline
WA_V_OIJNOMI_LDS_BS_STR-FLUSHFLAG sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LDIND sy-vline
WA_V_OIJNOMI_LDS_BS_STR-LIGHTNOMIT sy-vline
WA_V_OIJNOMI_LDS_BS_STR-SCHED_TST_FROM sy-vline
WA_V_OIJNOMI_LDS_BS_STR-SCHED_TST_TO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.