ABAP Select data from SAP table V_O2C_FICA_WLLOC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_O2C_FICA_WLLOC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_O2C_FICA_WLLOC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_O2C_FICA_WLLOC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_O2C_FICA_WLLOC TYPE STANDARD TABLE OF V_O2C_FICA_WLLOC,
      WA_V_O2C_FICA_WLLOC TYPE V_O2C_FICA_WLLOC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_O2C_FICA_WLLOC> TYPE V_O2C_FICA_WLLOC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_O2C_FICA_WLLOC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_O2C_FICA_WLLOC
  INTO TABLE IT_V_O2C_FICA_WLLOC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_O2C_FICA_WLLOC
*  INTO TABLE @DATA(IT_V_O2C_FICA_WLLOC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_O2C_FICA_WLLOC INDEX 1 INTO DATA(WA_V_O2C_FICA_WLLOC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_O2C_FICA_WLLOC ASSIGNING <V_O2C_FICA_WLLOC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_O2C_FICA_WLLOC>-MANDT = 1.
<V_O2C_FICA_WLLOC>-OPBEL = 1.
<V_O2C_FICA_WLLOC>-OPUPW = 1.
<V_O2C_FICA_WLLOC>-OPUPK = 1.
<V_O2C_FICA_WLLOC>-OPUPZ = 1.
ENDLOOP.

LOOP AT IT_V_O2C_FICA_WLLOC INTO WA_V_O2C_FICA_WLLOC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_O2C_FICA_WLLOC-LOOBJ1, sy-vline,
WA_V_O2C_FICA_WLLOC-FDATE, sy-vline,
WA_V_O2C_FICA_WLLOC-TDATE, sy-vline,
WA_V_O2C_FICA_WLLOC-VKONT, sy-vline,
WA_V_O2C_FICA_WLLOC-GPART, sy-vline,
WA_V_O2C_FICA_WLLOC-VTREF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_O2C_FICA_WLLOC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_O2C_FICA_WLLOC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_O2C_FICA_WLLOC INTO WA_V_O2C_FICA_WLLOC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field OPBEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_O2C_FICA_WLLOC-OPBEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_O2C_FICA_WLLOC-OPBEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_O2C_FICA_WLLOC-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_O2C_FICA_WLLOC-VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_O2C_FICA_WLLOC-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_O2C_FICA_WLLOC-GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VTREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_O2C_FICA_WLLOC-VTREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_O2C_FICA_WLLOC-VTREF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_O2C_FICA_WLLOC_STR,
MANDT TYPE STRING,
OPBEL TYPE STRING,
OPUPW TYPE STRING,
OPUPK TYPE STRING,
OPUPZ TYPE STRING,
LOOBJ1 TYPE STRING,
FDATE TYPE STRING,
TDATE TYPE STRING,
VKONT TYPE STRING,
GPART TYPE STRING,
VTREF TYPE STRING,
LOTYP TYPE STRING,
LOCKR TYPE STRING,
VKTYP TYPE STRING,
ADATUM TYPE STRING,
DURATION TYPE STRING,
LFDNR TYPE STRING,
BUKRS TYPE STRING,
SPART TYPE STRING,
HVORG TYPE STRING,
PYMET TYPE STRING,
PYMET_CA TYPE STRING,
MAHNV TYPE STRING,
MAHNV_CA TYPE STRING,
STRAT TYPE STRING,
BETRW TYPE STRING,
WAERS TYPE STRING,
NAME_FIRST TYPE STRING,
NAME_LAST TYPE STRING,
BUSINESSPARTNERNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_O2C_FICA_WLLOC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_O2C_FICA_WLLOC_STR-MANDT sy-vline
WA_V_O2C_FICA_WLLOC_STR-OPBEL sy-vline
WA_V_O2C_FICA_WLLOC_STR-OPUPW sy-vline
WA_V_O2C_FICA_WLLOC_STR-OPUPK sy-vline
WA_V_O2C_FICA_WLLOC_STR-OPUPZ sy-vline
WA_V_O2C_FICA_WLLOC_STR-LOOBJ1 sy-vline
WA_V_O2C_FICA_WLLOC_STR-FDATE sy-vline
WA_V_O2C_FICA_WLLOC_STR-TDATE sy-vline
WA_V_O2C_FICA_WLLOC_STR-VKONT sy-vline
WA_V_O2C_FICA_WLLOC_STR-GPART sy-vline
WA_V_O2C_FICA_WLLOC_STR-VTREF sy-vline
WA_V_O2C_FICA_WLLOC_STR-LOTYP sy-vline
WA_V_O2C_FICA_WLLOC_STR-LOCKR sy-vline
WA_V_O2C_FICA_WLLOC_STR-VKTYP sy-vline
WA_V_O2C_FICA_WLLOC_STR-ADATUM sy-vline
WA_V_O2C_FICA_WLLOC_STR-DURATION sy-vline
WA_V_O2C_FICA_WLLOC_STR-LFDNR sy-vline
WA_V_O2C_FICA_WLLOC_STR-BUKRS sy-vline
WA_V_O2C_FICA_WLLOC_STR-SPART sy-vline
WA_V_O2C_FICA_WLLOC_STR-HVORG sy-vline
WA_V_O2C_FICA_WLLOC_STR-PYMET sy-vline
WA_V_O2C_FICA_WLLOC_STR-PYMET_CA sy-vline
WA_V_O2C_FICA_WLLOC_STR-MAHNV sy-vline
WA_V_O2C_FICA_WLLOC_STR-MAHNV_CA sy-vline
WA_V_O2C_FICA_WLLOC_STR-STRAT sy-vline
WA_V_O2C_FICA_WLLOC_STR-BETRW sy-vline
WA_V_O2C_FICA_WLLOC_STR-WAERS sy-vline
WA_V_O2C_FICA_WLLOC_STR-NAME_FIRST sy-vline
WA_V_O2C_FICA_WLLOC_STR-NAME_LAST sy-vline
WA_V_O2C_FICA_WLLOC_STR-BUSINESSPARTNERNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.