ABAP Select data from SAP table V_MMIM_GR4PO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_MMIM_GR4PO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_MMIM_GR4PO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_MMIM_GR4PO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_MMIM_GR4PO TYPE STANDARD TABLE OF V_MMIM_GR4PO,
      WA_V_MMIM_GR4PO TYPE V_MMIM_GR4PO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_MMIM_GR4PO> TYPE V_MMIM_GR4PO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_MMIM_GR4PO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_MMIM_GR4PO
  INTO TABLE IT_V_MMIM_GR4PO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_MMIM_GR4PO
*  INTO TABLE @DATA(IT_V_MMIM_GR4PO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_MMIM_GR4PO INDEX 1 INTO DATA(WA_V_MMIM_GR4PO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_MMIM_GR4PO ASSIGNING <V_MMIM_GR4PO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_MMIM_GR4PO>-MANDT = 1.
<V_MMIM_GR4PO>-EBELN = 1.
<V_MMIM_GR4PO>-LIFNR = 1.
<V_MMIM_GR4PO>-EBELP = 1.
<V_MMIM_GR4PO>-BEDAT = 1.
ENDLOOP.

LOOP AT IT_V_MMIM_GR4PO INTO WA_V_MMIM_GR4PO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_MMIM_GR4PO-BSART, sy-vline,
WA_V_MMIM_GR4PO-EKORG, sy-vline,
WA_V_MMIM_GR4PO-EKGRP, sy-vline,
WA_V_MMIM_GR4PO-FRGRL, sy-vline,
WA_V_MMIM_GR4PO-MATNR, sy-vline,
WA_V_MMIM_GR4PO-NAME1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_MMIM_GR4PO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_MMIM_GR4PO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_MMIM_GR4PO INTO WA_V_MMIM_GR4PO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_MMIM_GR4PO-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_MMIM_GR4PO-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_MMIM_GR4PO-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_MMIM_GR4PO-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_V_MMIM_GR4PO-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_MMIM_GR4PO-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field EMATN CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_V_MMIM_GR4PO-EMATN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_MMIM_GR4PO-EMATN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_MMIM_GR4PO_STR,
MANDT TYPE STRING,
EBELN TYPE STRING,
LIFNR TYPE STRING,
EBELP TYPE STRING,
BEDAT TYPE STRING,
BSART TYPE STRING,
EKORG TYPE STRING,
EKGRP TYPE STRING,
FRGRL TYPE STRING,
MATNR TYPE STRING,
NAME1 TYPE STRING,
ORT01 TYPE STRING,
TXZ01 TYPE STRING,
LOEKZ TYPE STRING,
ELIKZ TYPE STRING,
XCHPF TYPE STRING,
EMATN TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_MMIM_GR4PO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_MMIM_GR4PO_STR-MANDT sy-vline
WA_V_MMIM_GR4PO_STR-EBELN sy-vline
WA_V_MMIM_GR4PO_STR-LIFNR sy-vline
WA_V_MMIM_GR4PO_STR-EBELP sy-vline
WA_V_MMIM_GR4PO_STR-BEDAT sy-vline
WA_V_MMIM_GR4PO_STR-BSART sy-vline
WA_V_MMIM_GR4PO_STR-EKORG sy-vline
WA_V_MMIM_GR4PO_STR-EKGRP sy-vline
WA_V_MMIM_GR4PO_STR-FRGRL sy-vline
WA_V_MMIM_GR4PO_STR-MATNR sy-vline
WA_V_MMIM_GR4PO_STR-NAME1 sy-vline
WA_V_MMIM_GR4PO_STR-ORT01 sy-vline
WA_V_MMIM_GR4PO_STR-TXZ01 sy-vline
WA_V_MMIM_GR4PO_STR-LOEKZ sy-vline
WA_V_MMIM_GR4PO_STR-ELIKZ sy-vline
WA_V_MMIM_GR4PO_STR-XCHPF sy-vline
WA_V_MMIM_GR4PO_STR-EMATN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.