ABAP Select data from SAP table V_HRP1771_1001 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_HRP1771_1001 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_HRP1771_1001. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_HRP1771_1001 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_HRP1771_1001 TYPE STANDARD TABLE OF V_HRP1771_1001,
      WA_V_HRP1771_1001 TYPE V_HRP1771_1001,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_HRP1771_1001> TYPE V_HRP1771_1001.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_HRP1771_1001.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_HRP1771_1001
  INTO TABLE IT_V_HRP1771_1001.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_HRP1771_1001
*  INTO TABLE @DATA(IT_V_HRP1771_10012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_HRP1771_1001 INDEX 1 INTO DATA(WA_V_HRP1771_10012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_HRP1771_1001 ASSIGNING <V_HRP1771_1001>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_HRP1771_1001>-MANDT = 1.
<V_HRP1771_1001>-PLVAR = 1.
<V_HRP1771_1001>-OTYPE = 1.
<V_HRP1771_1001>-OBJID = 1.
<V_HRP1771_1001>-SUBTY = 1.
ENDLOOP.

LOOP AT IT_V_HRP1771_1001 INTO WA_V_HRP1771_1001.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_HRP1771_1001-ISTAT, sy-vline,
WA_V_HRP1771_1001-BEGDA, sy-vline,
WA_V_HRP1771_1001-ENDDA, sy-vline,
WA_V_HRP1771_1001-VARYF, sy-vline,
WA_V_HRP1771_1001-SEQNR, sy-vline,
WA_V_HRP1771_1001-INFTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_HRP1771_1001 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_HRP1771_1001 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_HRP1771_1001 INTO WA_V_HRP1771_1001. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_HRP1771_1001_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
INFTY TYPE STRING,
OTJID TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
AYEAR TYPE STRING,
PERID TYPE STRING,
PR_STATUS TYPE STRING,
PRS_STATE TYPE STRING,
APPTYPE TYPE STRING,
REASON TYPE STRING,
ACLEVEL TYPE STRING,
REGDATE TYPE STRING,
FEEFL TYPE STRING,
REG_CERT_DATE TYPE STRING,
PERCT TYPE STRING,
REGCLASS TYPE STRING,
CANCPROCESS TYPE STRING,
CANCREASON TYPE STRING,
CANCDATE TYPE STRING,
ADM_GUID TYPE STRING,
P1001_RSIGN TYPE STRING,
P1001_RELAT TYPE STRING,
P1001_ISTAT TYPE STRING,
P1001_PRIOX TYPE STRING,
P1001_BEGDA TYPE STRING,
P1001_ENDDA TYPE STRING,
P1001_SCLAS TYPE STRING,
P1001_SOBID TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_HRP1771_1001_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_HRP1771_1001_STR-MANDT sy-vline
WA_V_HRP1771_1001_STR-PLVAR sy-vline
WA_V_HRP1771_1001_STR-OTYPE sy-vline
WA_V_HRP1771_1001_STR-OBJID sy-vline
WA_V_HRP1771_1001_STR-SUBTY sy-vline
WA_V_HRP1771_1001_STR-ISTAT sy-vline
WA_V_HRP1771_1001_STR-BEGDA sy-vline
WA_V_HRP1771_1001_STR-ENDDA sy-vline
WA_V_HRP1771_1001_STR-VARYF sy-vline
WA_V_HRP1771_1001_STR-SEQNR sy-vline
WA_V_HRP1771_1001_STR-INFTY sy-vline
WA_V_HRP1771_1001_STR-OTJID sy-vline
WA_V_HRP1771_1001_STR-AEDTM sy-vline
WA_V_HRP1771_1001_STR-UNAME sy-vline
WA_V_HRP1771_1001_STR-REASN sy-vline
WA_V_HRP1771_1001_STR-HISTO sy-vline
WA_V_HRP1771_1001_STR-ITXNR sy-vline
WA_V_HRP1771_1001_STR-AYEAR sy-vline
WA_V_HRP1771_1001_STR-PERID sy-vline
WA_V_HRP1771_1001_STR-PR_STATUS sy-vline
WA_V_HRP1771_1001_STR-PRS_STATE sy-vline
WA_V_HRP1771_1001_STR-APPTYPE sy-vline
WA_V_HRP1771_1001_STR-REASON sy-vline
WA_V_HRP1771_1001_STR-ACLEVEL sy-vline
WA_V_HRP1771_1001_STR-REGDATE sy-vline
WA_V_HRP1771_1001_STR-FEEFL sy-vline
WA_V_HRP1771_1001_STR-REG_CERT_DATE sy-vline
WA_V_HRP1771_1001_STR-PERCT sy-vline
WA_V_HRP1771_1001_STR-REGCLASS sy-vline
WA_V_HRP1771_1001_STR-CANCPROCESS sy-vline
WA_V_HRP1771_1001_STR-CANCREASON sy-vline
WA_V_HRP1771_1001_STR-CANCDATE sy-vline
WA_V_HRP1771_1001_STR-ADM_GUID sy-vline
WA_V_HRP1771_1001_STR-P1001_RSIGN sy-vline
WA_V_HRP1771_1001_STR-P1001_RELAT sy-vline
WA_V_HRP1771_1001_STR-P1001_ISTAT sy-vline
WA_V_HRP1771_1001_STR-P1001_PRIOX sy-vline
WA_V_HRP1771_1001_STR-P1001_BEGDA sy-vline
WA_V_HRP1771_1001_STR-P1001_ENDDA sy-vline
WA_V_HRP1771_1001_STR-P1001_SCLAS sy-vline
WA_V_HRP1771_1001_STR-P1001_SOBID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.