ABAP Select data from SAP table V_FMPD_SHELP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_FMPD_SHELP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_FMPD_SHELP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_FMPD_SHELP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_FMPD_SHELP TYPE STANDARD TABLE OF V_FMPD_SHELP,
      WA_V_FMPD_SHELP TYPE V_FMPD_SHELP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_FMPD_SHELP> TYPE V_FMPD_SHELP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_FMPD_SHELP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_FMPD_SHELP
  INTO TABLE IT_V_FMPD_SHELP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_FMPD_SHELP
*  INTO TABLE @DATA(IT_V_FMPD_SHELP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_FMPD_SHELP INDEX 1 INTO DATA(WA_V_FMPD_SHELP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_FMPD_SHELP ASSIGNING <V_FMPD_SHELP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_FMPD_SHELP>-MANDT = 1.
<V_FMPD_SHELP>-ANWND = 1.
<V_FMPD_SHELP>-ABSND = 1.
<V_FMPD_SHELP>-AZIDT = 1.
<V_FMPD_SHELP>-EMKEY = 1.
ENDLOOP.

LOOP AT IT_V_FMPD_SHELP INTO WA_V_FMPD_SHELP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_FMPD_SHELP-EUSER, sy-vline,
WA_V_FMPD_SHELP-EDATE, sy-vline,
WA_V_FMPD_SHELP-VB1OK, sy-vline,
WA_V_FMPD_SHELP-VB2OK, sy-vline,
WA_V_FMPD_SHELP-KIPRE, sy-vline,
WA_V_FMPD_SHELP-HKONT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_FMPD_SHELP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_FMPD_SHELP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_FMPD_SHELP INTO WA_V_FMPD_SHELP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field HKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_FMPD_SHELP-HKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_FMPD_SHELP-HKONT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_FMPD_SHELP_STR,
MANDT TYPE STRING,
ANWND TYPE STRING,
ABSND TYPE STRING,
AZIDT TYPE STRING,
EMKEY TYPE STRING,
EUSER TYPE STRING,
EDATE TYPE STRING,
VB1OK TYPE STRING,
VB2OK TYPE STRING,
KIPRE TYPE STRING,
HKONT TYPE STRING,
BUKRS TYPE STRING,
WAERS TYPE STRING,
AZDAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_FMPD_SHELP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_FMPD_SHELP_STR-MANDT sy-vline
WA_V_FMPD_SHELP_STR-ANWND sy-vline
WA_V_FMPD_SHELP_STR-ABSND sy-vline
WA_V_FMPD_SHELP_STR-AZIDT sy-vline
WA_V_FMPD_SHELP_STR-EMKEY sy-vline
WA_V_FMPD_SHELP_STR-EUSER sy-vline
WA_V_FMPD_SHELP_STR-EDATE sy-vline
WA_V_FMPD_SHELP_STR-VB1OK sy-vline
WA_V_FMPD_SHELP_STR-VB2OK sy-vline
WA_V_FMPD_SHELP_STR-KIPRE sy-vline
WA_V_FMPD_SHELP_STR-HKONT sy-vline
WA_V_FMPD_SHELP_STR-BUKRS sy-vline
WA_V_FMPD_SHELP_STR-WAERS sy-vline
WA_V_FMPD_SHELP_STR-AZDAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.