ABAP Select data from SAP table V_FKKCO_CD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_FKKCO_CD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_FKKCO_CD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_FKKCO_CD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_FKKCO_CD TYPE STANDARD TABLE OF V_FKKCO_CD,
      WA_V_FKKCO_CD TYPE V_FKKCO_CD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_FKKCO_CD> TYPE V_FKKCO_CD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_FKKCO_CD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_FKKCO_CD
  INTO TABLE IT_V_FKKCO_CD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_FKKCO_CD
*  INTO TABLE @DATA(IT_V_FKKCO_CD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_FKKCO_CD INDEX 1 INTO DATA(WA_V_FKKCO_CD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_FKKCO_CD ASSIGNING <V_FKKCO_CD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_FKKCO_CD>-MANDT = 1.
<V_FKKCO_CD>-OPBEL = 1.
<V_FKKCO_CD>-OPUPK = 1.
<V_FKKCO_CD>-FIKEY = 1.
<V_FKKCO_CD>-XCOPA = 1.
ENDLOOP.

LOOP AT IT_V_FKKCO_CD INTO WA_V_FKKCO_CD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_FKKCO_CD-PAOBJNR, sy-vline,
WA_V_FKKCO_CD-PASUBNR, sy-vline,
WA_V_FKKCO_CD-BUKRS, sy-vline,
WA_V_FKKCO_CD-HKONT, sy-vline,
WA_V_FKKCO_CD-BUDAT, sy-vline,
WA_V_FKKCO_CD-WAERS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_FKKCO_CD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_FKKCO_CD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_FKKCO_CD INTO WA_V_FKKCO_CD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field OPBEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_FKKCO_CD-OPBEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_FKKCO_CD-OPBEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_FKKCO_CD-HKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_FKKCO_CD-HKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_FKKCO_CD-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_FKKCO_CD-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_FKKCO_CD-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_FKKCO_CD-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_FKKCO_CD-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_FKKCO_CD-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_FKKCO_CD-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_FKKCO_CD-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSF CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_V_FKKCO_CD-KURSF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_FKKCO_CD-KURSF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_FKKCO_CD-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_FKKCO_CD-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_FKKCO_CD-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_FKKCO_CD-GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VTREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_FKKCO_CD-VTREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_FKKCO_CD-VTREF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_FKKCO_CD_STR,
MANDT TYPE STRING,
OPBEL TYPE STRING,
OPUPK TYPE STRING,
FIKEY TYPE STRING,
XCOPA TYPE STRING,
PAOBJNR TYPE STRING,
PASUBNR TYPE STRING,
BUKRS TYPE STRING,
HKONT TYPE STRING,
BUDAT TYPE STRING,
WAERS TYPE STRING,
BLDAT TYPE STRING,
GSBER TYPE STRING,
PRCTR TYPE STRING,
KOSTL TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
AUFNR TYPE STRING,
KURSF TYPE STRING,
BETRH TYPE STRING,
BETRW TYPE STRING,
BETR2 TYPE STRING,
BETR3 TYPE STRING,
MENGE TYPE STRING,
MEINS TYPE STRING,
WHGRP TYPE STRING,
GPART TYPE STRING,
VTREF TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_FKKCO_CD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_FKKCO_CD_STR-MANDT sy-vline
WA_V_FKKCO_CD_STR-OPBEL sy-vline
WA_V_FKKCO_CD_STR-OPUPK sy-vline
WA_V_FKKCO_CD_STR-FIKEY sy-vline
WA_V_FKKCO_CD_STR-XCOPA sy-vline
WA_V_FKKCO_CD_STR-PAOBJNR sy-vline
WA_V_FKKCO_CD_STR-PASUBNR sy-vline
WA_V_FKKCO_CD_STR-BUKRS sy-vline
WA_V_FKKCO_CD_STR-HKONT sy-vline
WA_V_FKKCO_CD_STR-BUDAT sy-vline
WA_V_FKKCO_CD_STR-WAERS sy-vline
WA_V_FKKCO_CD_STR-BLDAT sy-vline
WA_V_FKKCO_CD_STR-GSBER sy-vline
WA_V_FKKCO_CD_STR-PRCTR sy-vline
WA_V_FKKCO_CD_STR-KOSTL sy-vline
WA_V_FKKCO_CD_STR-KDAUF sy-vline
WA_V_FKKCO_CD_STR-KDPOS sy-vline
WA_V_FKKCO_CD_STR-AUFNR sy-vline
WA_V_FKKCO_CD_STR-KURSF sy-vline
WA_V_FKKCO_CD_STR-BETRH sy-vline
WA_V_FKKCO_CD_STR-BETRW sy-vline
WA_V_FKKCO_CD_STR-BETR2 sy-vline
WA_V_FKKCO_CD_STR-BETR3 sy-vline
WA_V_FKKCO_CD_STR-MENGE sy-vline
WA_V_FKKCO_CD_STR-MEINS sy-vline
WA_V_FKKCO_CD_STR-WHGRP sy-vline
WA_V_FKKCO_CD_STR-GPART sy-vline
WA_V_FKKCO_CD_STR-VTREF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.