ABAP Select data from SAP table V_EINE_MKAL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_EINE_MKAL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_EINE_MKAL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_EINE_MKAL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_EINE_MKAL TYPE STANDARD TABLE OF V_EINE_MKAL,
      WA_V_EINE_MKAL TYPE V_EINE_MKAL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_EINE_MKAL> TYPE V_EINE_MKAL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_EINE_MKAL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_EINE_MKAL
  INTO TABLE IT_V_EINE_MKAL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_EINE_MKAL
*  INTO TABLE @DATA(IT_V_EINE_MKAL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_EINE_MKAL INDEX 1 INTO DATA(WA_V_EINE_MKAL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_EINE_MKAL ASSIGNING <V_EINE_MKAL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_EINE_MKAL>-MANDT = 1.
<V_EINE_MKAL>-INFNR = 1.
<V_EINE_MKAL>-MATNR = 1.
<V_EINE_MKAL>-WERKS = 1.
<V_EINE_MKAL>-VERID = 1.
ENDLOOP.

LOOP AT IT_V_EINE_MKAL INTO WA_V_EINE_MKAL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_EINE_MKAL-BDATU, sy-vline,
WA_V_EINE_MKAL-ADATU, sy-vline,
WA_V_EINE_MKAL-STLAL, sy-vline,
WA_V_EINE_MKAL-STLAN, sy-vline,
WA_V_EINE_MKAL-PLNTY, sy-vline,
WA_V_EINE_MKAL-PLNNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_EINE_MKAL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_EINE_MKAL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_EINE_MKAL INTO WA_V_EINE_MKAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_EINE_MKAL-INFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_EINE_MKAL-INFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_V_EINE_MKAL-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_EINE_MKAL-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_EINE_MKAL-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_EINE_MKAL-STLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_EINE_MKAL-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_EINE_MKAL-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ALNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_EINE_MKAL-ALNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_EINE_MKAL-ALNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_EINE_MKAL-PLNNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_EINE_MKAL-PLNNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ALNAG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_EINE_MKAL-ALNAG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_EINE_MKAL-ALNAG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_EINE_MKAL-PLNNM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_EINE_MKAL-PLNNM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ALNAM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_EINE_MKAL-ALNAM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_EINE_MKAL-ALNAM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATKO CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_V_EINE_MKAL-MATKO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_EINE_MKAL-MATKO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field UCMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_V_EINE_MKAL-UCMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_EINE_MKAL-UCMAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_EINE_MKAL_STR,
MANDT TYPE STRING,
INFNR TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
VERID TYPE STRING,
BDATU TYPE STRING,
ADATU TYPE STRING,
STLAL TYPE STRING,
STLAN TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
ALNAL TYPE STRING,
BESKZ TYPE STRING,
SOBSL TYPE STRING,
LOSGR TYPE STRING,
MDV01 TYPE STRING,
MDV02 TYPE STRING,
TEXT1 TYPE STRING,
EWAHR TYPE STRING,
VERTO TYPE STRING,
SERKZ TYPE STRING,
BSTMI TYPE STRING,
BSTMA TYPE STRING,
RGEKZ TYPE STRING,
ALORT TYPE STRING,
PLTYG TYPE STRING,
PLNNG TYPE STRING,
ALNAG TYPE STRING,
PLTYM TYPE STRING,
PLNNM TYPE STRING,
ALNAM TYPE STRING,
CSPLT TYPE STRING,
MATKO TYPE STRING,
ELPRO TYPE STRING,
PRVBE TYPE STRING,
PRFG_F TYPE STRING,
PRDAT TYPE STRING,
MKSP TYPE STRING,
PRFG_R TYPE STRING,
PRFG_G TYPE STRING,
PRFG_S TYPE STRING,
UCMAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_EINE_MKAL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_EINE_MKAL_STR-MANDT sy-vline
WA_V_EINE_MKAL_STR-INFNR sy-vline
WA_V_EINE_MKAL_STR-MATNR sy-vline
WA_V_EINE_MKAL_STR-WERKS sy-vline
WA_V_EINE_MKAL_STR-VERID sy-vline
WA_V_EINE_MKAL_STR-BDATU sy-vline
WA_V_EINE_MKAL_STR-ADATU sy-vline
WA_V_EINE_MKAL_STR-STLAL sy-vline
WA_V_EINE_MKAL_STR-STLAN sy-vline
WA_V_EINE_MKAL_STR-PLNTY sy-vline
WA_V_EINE_MKAL_STR-PLNNR sy-vline
WA_V_EINE_MKAL_STR-ALNAL sy-vline
WA_V_EINE_MKAL_STR-BESKZ sy-vline
WA_V_EINE_MKAL_STR-SOBSL sy-vline
WA_V_EINE_MKAL_STR-LOSGR sy-vline
WA_V_EINE_MKAL_STR-MDV01 sy-vline
WA_V_EINE_MKAL_STR-MDV02 sy-vline
WA_V_EINE_MKAL_STR-TEXT1 sy-vline
WA_V_EINE_MKAL_STR-EWAHR sy-vline
WA_V_EINE_MKAL_STR-VERTO sy-vline
WA_V_EINE_MKAL_STR-SERKZ sy-vline
WA_V_EINE_MKAL_STR-BSTMI sy-vline
WA_V_EINE_MKAL_STR-BSTMA sy-vline
WA_V_EINE_MKAL_STR-RGEKZ sy-vline
WA_V_EINE_MKAL_STR-ALORT sy-vline
WA_V_EINE_MKAL_STR-PLTYG sy-vline
WA_V_EINE_MKAL_STR-PLNNG sy-vline
WA_V_EINE_MKAL_STR-ALNAG sy-vline
WA_V_EINE_MKAL_STR-PLTYM sy-vline
WA_V_EINE_MKAL_STR-PLNNM sy-vline
WA_V_EINE_MKAL_STR-ALNAM sy-vline
WA_V_EINE_MKAL_STR-CSPLT sy-vline
WA_V_EINE_MKAL_STR-MATKO sy-vline
WA_V_EINE_MKAL_STR-ELPRO sy-vline
WA_V_EINE_MKAL_STR-PRVBE sy-vline
WA_V_EINE_MKAL_STR-PRFG_F sy-vline
WA_V_EINE_MKAL_STR-PRDAT sy-vline
WA_V_EINE_MKAL_STR-MKSP sy-vline
WA_V_EINE_MKAL_STR-PRFG_R sy-vline
WA_V_EINE_MKAL_STR-PRFG_G sy-vline
WA_V_EINE_MKAL_STR-PRFG_S sy-vline
WA_V_EINE_MKAL_STR-UCMAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.