ABAP Select data from SAP table V_COSP_KSII into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_COSP_KSII table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_COSP_KSII. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_COSP_KSII table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_COSP_KSII TYPE STANDARD TABLE OF V_COSP_KSII,
      WA_V_COSP_KSII TYPE V_COSP_KSII,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_COSP_KSII> TYPE V_COSP_KSII.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_COSP_KSII.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_COSP_KSII
  INTO TABLE IT_V_COSP_KSII.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_COSP_KSII
*  INTO TABLE @DATA(IT_V_COSP_KSII2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_COSP_KSII INDEX 1 INTO DATA(WA_V_COSP_KSII2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_COSP_KSII ASSIGNING <V_COSP_KSII>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_COSP_KSII>-MANDT = 1.
<V_COSP_KSII>-LEDNR = 1.
<V_COSP_KSII>-OBJNR = 1.
<V_COSP_KSII>-GJAHR = 1.
<V_COSP_KSII>-PERIO = 1.
ENDLOOP.

LOOP AT IT_V_COSP_KSII INTO WA_V_COSP_KSII.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_COSP_KSII-WRTTP, sy-vline,
WA_V_COSP_KSII-VERSN, sy-vline,
WA_V_COSP_KSII-KSTAR, sy-vline,
WA_V_COSP_KSII-HRKFT, sy-vline,
WA_V_COSP_KSII-VRGNG, sy-vline,
WA_V_COSP_KSII-VBUND, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_COSP_KSII you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_COSP_KSII TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_COSP_KSII INTO WA_V_COSP_KSII. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_V_COSP_KSII-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_COSP_KSII-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_COSP_KSII-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_COSP_KSII-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KSTAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_COSP_KSII-KSTAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_COSP_KSII-KSTAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBUND CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V_COSP_KSII-VBUND IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_COSP_KSII-VBUND.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BEKNZ, internal->external for field BEKNZ CALL FUNCTION 'CONVERSION_EXIT_BEKNZ_OUTPUT' EXPORTING input = WA_V_COSP_KSII-BEKNZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_COSP_KSII-BEKNZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V_COSP_KSII-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_COSP_KSII-MEINH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_COSP_KSII_STR,
MANDT TYPE STRING,
LEDNR TYPE STRING,
OBJNR TYPE STRING,
GJAHR TYPE STRING,
PERIO TYPE STRING,
WRTTP TYPE STRING,
VERSN TYPE STRING,
KSTAR TYPE STRING,
HRKFT TYPE STRING,
VRGNG TYPE STRING,
VBUND TYPE STRING,
PARGB TYPE STRING,
BEKNZ TYPE STRING,
TWAER TYPE STRING,
PERBL TYPE STRING,
MEINH TYPE STRING,
ROCUR TYPE STRING,
RKCUR TYPE STRING,
WTG TYPE STRING,
WOG TYPE STRING,
WKG TYPE STRING,
WKF TYPE STRING,
PAG TYPE STRING,
MEG TYPE STRING,
MEF TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_COSP_KSII_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_COSP_KSII_STR-MANDT sy-vline
WA_V_COSP_KSII_STR-LEDNR sy-vline
WA_V_COSP_KSII_STR-OBJNR sy-vline
WA_V_COSP_KSII_STR-GJAHR sy-vline
WA_V_COSP_KSII_STR-PERIO sy-vline
WA_V_COSP_KSII_STR-WRTTP sy-vline
WA_V_COSP_KSII_STR-VERSN sy-vline
WA_V_COSP_KSII_STR-KSTAR sy-vline
WA_V_COSP_KSII_STR-HRKFT sy-vline
WA_V_COSP_KSII_STR-VRGNG sy-vline
WA_V_COSP_KSII_STR-VBUND sy-vline
WA_V_COSP_KSII_STR-PARGB sy-vline
WA_V_COSP_KSII_STR-BEKNZ sy-vline
WA_V_COSP_KSII_STR-TWAER sy-vline
WA_V_COSP_KSII_STR-PERBL sy-vline
WA_V_COSP_KSII_STR-MEINH sy-vline
WA_V_COSP_KSII_STR-ROCUR sy-vline
WA_V_COSP_KSII_STR-RKCUR sy-vline
WA_V_COSP_KSII_STR-WTG sy-vline
WA_V_COSP_KSII_STR-WOG sy-vline
WA_V_COSP_KSII_STR-WKG sy-vline
WA_V_COSP_KSII_STR-WKF sy-vline
WA_V_COSP_KSII_STR-PAG sy-vline
WA_V_COSP_KSII_STR-MEG sy-vline
WA_V_COSP_KSII_STR-MEF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.