ABAP Select data from SAP table V_CCTYPE_BULKSBR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_CCTYPE_BULKSBR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_CCTYPE_BULKSBR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_CCTYPE_BULKSBR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_CCTYPE_BULKSBR TYPE STANDARD TABLE OF V_CCTYPE_BULKSBR,
      WA_V_CCTYPE_BULKSBR TYPE V_CCTYPE_BULKSBR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_CCTYPE_BULKSBR> TYPE V_CCTYPE_BULKSBR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_CCTYPE_BULKSBR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_CCTYPE_BULKSBR
  INTO TABLE IT_V_CCTYPE_BULKSBR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_CCTYPE_BULKSBR
*  INTO TABLE @DATA(IT_V_CCTYPE_BULKSBR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_CCTYPE_BULKSBR INDEX 1 INTO DATA(WA_V_CCTYPE_BULKSBR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_CCTYPE_BULKSBR ASSIGNING <V_CCTYPE_BULKSBR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_CCTYPE_BULKSBR>-CLIENT = 1.
<V_CCTYPE_BULKSBR>-CCTYPE = 1.
<V_CCTYPE_BULKSBR>-SUBTYPE = 1.
<V_CCTYPE_BULKSBR>-LANGU1 = 1.
<V_CCTYPE_BULKSBR>-LANGU2 = 1.
ENDLOOP.

LOOP AT IT_V_CCTYPE_BULKSBR INTO WA_V_CCTYPE_BULKSBR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_CCTYPE_BULKSBR-CCTYPEN, sy-vline,
WA_V_CCTYPE_BULKSBR-NAME, sy-vline,
WA_V_CCTYPE_BULKSBR-VARTP, sy-vline,
WA_V_CCTYPE_BULKSBR-CLTYPE_DUMMY, sy-vline,
WA_V_CCTYPE_BULKSBR-POLPROD, sy-vline,
WA_V_CCTYPE_BULKSBR-LOSSTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_CCTYPE_BULKSBR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_CCTYPE_BULKSBR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_CCTYPE_BULKSBR INTO WA_V_CCTYPE_BULKSBR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGU1 CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_V_CCTYPE_BULKSBR-LANGU1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_CCTYPE_BULKSBR-LANGU1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU2 CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_V_CCTYPE_BULKSBR-LANGU2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_CCTYPE_BULKSBR-LANGU2.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_CCTYPE_BULKSBR_STR,
CLIENT TYPE STRING,
CCTYPE TYPE STRING,
SUBTYPE TYPE STRING,
LANGU1 TYPE STRING,
LANGU2 TYPE STRING,
CCTYPEN TYPE STRING,
NAME TYPE STRING,
VARTP TYPE STRING,
CLTYPE_DUMMY TYPE STRING,
POLPROD TYPE STRING,
LOSSTYPE TYPE STRING,
XREGION TYPE STRING,
XINSURED TYPE STRING,
XDATELOSS TYPE STRING,
PAIDITEMSELECT TYPE STRING,
XDATECLNOTIF TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_CCTYPE_BULKSBR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_CCTYPE_BULKSBR_STR-CLIENT sy-vline
WA_V_CCTYPE_BULKSBR_STR-CCTYPE sy-vline
WA_V_CCTYPE_BULKSBR_STR-SUBTYPE sy-vline
WA_V_CCTYPE_BULKSBR_STR-LANGU1 sy-vline
WA_V_CCTYPE_BULKSBR_STR-LANGU2 sy-vline
WA_V_CCTYPE_BULKSBR_STR-CCTYPEN sy-vline
WA_V_CCTYPE_BULKSBR_STR-NAME sy-vline
WA_V_CCTYPE_BULKSBR_STR-VARTP sy-vline
WA_V_CCTYPE_BULKSBR_STR-CLTYPE_DUMMY sy-vline
WA_V_CCTYPE_BULKSBR_STR-POLPROD sy-vline
WA_V_CCTYPE_BULKSBR_STR-LOSSTYPE sy-vline
WA_V_CCTYPE_BULKSBR_STR-XREGION sy-vline
WA_V_CCTYPE_BULKSBR_STR-XINSURED sy-vline
WA_V_CCTYPE_BULKSBR_STR-XDATELOSS sy-vline
WA_V_CCTYPE_BULKSBR_STR-PAIDITEMSELECT sy-vline
WA_V_CCTYPE_BULKSBR_STR-XDATECLNOTIF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.