ABAP Select data from SAP table V_BULKYCUST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_BULKYCUST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_BULKYCUST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_BULKYCUST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_BULKYCUST TYPE STANDARD TABLE OF V_BULKYCUST,
      WA_V_BULKYCUST TYPE V_BULKYCUST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_BULKYCUST> TYPE V_BULKYCUST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_BULKYCUST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_BULKYCUST
  INTO TABLE IT_V_BULKYCUST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_BULKYCUST
*  INTO TABLE @DATA(IT_V_BULKYCUST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_BULKYCUST INDEX 1 INTO DATA(WA_V_BULKYCUST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_BULKYCUST ASSIGNING <V_BULKYCUST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_BULKYCUST>-MANDT = 1.
<V_BULKYCUST>-SPAUA = 1.
<V_BULKYCUST>-MATKL = 1.
<V_BULKYCUST>-VKORG = 1.
<V_BULKYCUST>-VTWEG = 1.
ENDLOOP.

LOOP AT IT_V_BULKYCUST INTO WA_V_BULKYCUST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_BULKYCUST-SPART, sy-vline,
WA_V_BULKYCUST-AUART, sy-vline,
WA_V_BULKYCUST-WERKS, sy-vline,
WA_V_BULKYCUST-PSTYV_EXP, sy-vline,
WA_V_BULKYCUST-PSTYV_N, sy-vline,
WA_V_BULKYCUST-PSTYV_VOR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_BULKYCUST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_BULKYCUST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_BULKYCUST INTO WA_V_BULKYCUST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit AUART, internal->external for field AUART CALL FUNCTION 'CONVERSION_EXIT_AUART_OUTPUT' EXPORTING input = WA_V_BULKYCUST-AUART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_BULKYCUST-AUART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_V_BULKYCUST-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V_BULKYCUST-SPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_BULKYCUST_STR,
MANDT TYPE STRING,
SPAUA TYPE STRING,
MATKL TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
AUART TYPE STRING,
WERKS TYPE STRING,
PSTYV_EXP TYPE STRING,
PSTYV_N TYPE STRING,
PSTYV_VOR TYPE STRING,
PSTYV_BAR TYPE STRING,
PSTYV_K TYPE STRING,
PRDEF TYPE STRING,
KOND0 TYPE STRING,
KOND0_PRS TYPE STRING,
KOND1 TYPE STRING,
KOND2 TYPE STRING,
KOND3 TYPE STRING,
KOND4 TYPE STRING,
SPRAS TYPE STRING,
LFDTX TYPE STRING,
PRODUCT_AREA TYPE STRING,
MTART TYPE STRING,
SERVICE_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_BULKYCUST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_BULKYCUST_STR-MANDT sy-vline
WA_V_BULKYCUST_STR-SPAUA sy-vline
WA_V_BULKYCUST_STR-MATKL sy-vline
WA_V_BULKYCUST_STR-VKORG sy-vline
WA_V_BULKYCUST_STR-VTWEG sy-vline
WA_V_BULKYCUST_STR-SPART sy-vline
WA_V_BULKYCUST_STR-AUART sy-vline
WA_V_BULKYCUST_STR-WERKS sy-vline
WA_V_BULKYCUST_STR-PSTYV_EXP sy-vline
WA_V_BULKYCUST_STR-PSTYV_N sy-vline
WA_V_BULKYCUST_STR-PSTYV_VOR sy-vline
WA_V_BULKYCUST_STR-PSTYV_BAR sy-vline
WA_V_BULKYCUST_STR-PSTYV_K sy-vline
WA_V_BULKYCUST_STR-PRDEF sy-vline
WA_V_BULKYCUST_STR-KOND0 sy-vline
WA_V_BULKYCUST_STR-KOND0_PRS sy-vline
WA_V_BULKYCUST_STR-KOND1 sy-vline
WA_V_BULKYCUST_STR-KOND2 sy-vline
WA_V_BULKYCUST_STR-KOND3 sy-vline
WA_V_BULKYCUST_STR-KOND4 sy-vline
WA_V_BULKYCUST_STR-SPRAS sy-vline
WA_V_BULKYCUST_STR-LFDTX sy-vline
WA_V_BULKYCUST_STR-PRODUCT_AREA sy-vline
WA_V_BULKYCUST_STR-MTART sy-vline
WA_V_BULKYCUST_STR-SERVICE_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.