ABAP Select data from SAP table V_74FD_JP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_74FD_JP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_74FD_JP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_74FD_JP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_74FD_JP TYPE STANDARD TABLE OF V_74FD_JP,
      WA_V_74FD_JP TYPE V_74FD_JP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_74FD_JP> TYPE V_74FD_JP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_74FD_JP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_74FD_JP
  INTO TABLE IT_V_74FD_JP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_74FD_JP
*  INTO TABLE @DATA(IT_V_74FD_JP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_74FD_JP INDEX 1 INTO DATA(WA_V_74FD_JP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_74FD_JP ASSIGNING <V_74FD_JP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_74FD_JP>-MANDT = 1.
<V_74FD_JP>-BAREA = 1.
<V_74FD_JP>-BPLAN = 1.
<V_74FD_JP>-ENDDA = 1.
<V_74FD_JP>-PLNTX = 1.
ENDLOOP.

LOOP AT IT_V_74FD_JP INTO WA_V_74FD_JP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_74FD_JP-IGRTX, sy-vline,
WA_V_74FD_JP-VESTX, sy-vline,
WA_V_74FD_JP-BEGDA, sy-vline,
WA_V_74FD_JP-INVGR, sy-vline,
WA_V_74FD_JP-VESTI, sy-vline,
WA_V_74FD_JP-ERCON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_74FD_JP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_74FD_JP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_74FD_JP INTO WA_V_74FD_JP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_74FD_JP_STR,
MANDT TYPE STRING,
BAREA TYPE STRING,
BPLAN TYPE STRING,
ENDDA TYPE STRING,
PLNTX TYPE STRING,
IGRTX TYPE STRING,
VESTX TYPE STRING,
BEGDA TYPE STRING,
INVGR TYPE STRING,
VESTI TYPE STRING,
ERCON TYPE STRING,
EECON TYPE STRING,
WDRAW TYPE STRING,
CUNIT TYPE STRING,
ERCTX TYPE STRING,
EECTX TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_74FD_JP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_74FD_JP_STR-MANDT sy-vline
WA_V_74FD_JP_STR-BAREA sy-vline
WA_V_74FD_JP_STR-BPLAN sy-vline
WA_V_74FD_JP_STR-ENDDA sy-vline
WA_V_74FD_JP_STR-PLNTX sy-vline
WA_V_74FD_JP_STR-IGRTX sy-vline
WA_V_74FD_JP_STR-VESTX sy-vline
WA_V_74FD_JP_STR-BEGDA sy-vline
WA_V_74FD_JP_STR-INVGR sy-vline
WA_V_74FD_JP_STR-VESTI sy-vline
WA_V_74FD_JP_STR-ERCON sy-vline
WA_V_74FD_JP_STR-EECON sy-vline
WA_V_74FD_JP_STR-WDRAW sy-vline
WA_V_74FD_JP_STR-CUNIT sy-vline
WA_V_74FD_JP_STR-ERCTX sy-vline
WA_V_74FD_JP_STR-EECTX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.