ABAP Select data from SAP table V_5DCD_2E into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_5DCD_2E table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_5DCD_2E. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_5DCD_2E table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_5DCD_2E TYPE STANDARD TABLE OF V_5DCD_2E,
      WA_V_5DCD_2E TYPE V_5DCD_2E,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_5DCD_2E> TYPE V_5DCD_2E.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_5DCD_2E.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_5DCD_2E
  INTO TABLE IT_V_5DCD_2E.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_5DCD_2E
*  INTO TABLE @DATA(IT_V_5DCD_2E2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_5DCD_2E INDEX 1 INTO DATA(WA_V_5DCD_2E2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_5DCD_2E ASSIGNING <V_5DCD_2E>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_5DCD_2E>-MANDT = 1.
<V_5DCD_2E>-ANTYP = 1.
<V_5DCD_2E>-ANSPR = 1.
<V_5DCD_2E>-MODBV = 1.
<V_5DCD_2E>-ENDDA = 1.
ENDLOOP.

LOOP AT IT_V_5DCD_2E INTO WA_V_5DCD_2E.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_5DCD_2E-BEGDA, sy-vline,
WA_V_5DCD_2E-ATEXT, sy-vline,
WA_V_5DCD_2E-MBVTX, sy-vline,
WA_V_5DCD_2E-LGART, sy-vline,
WA_V_5DCD_2E-LGART_TXT, sy-vline,
WA_V_5DCD_2E-RNTYP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_5DCD_2E you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_5DCD_2E TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_5DCD_2E INTO WA_V_5DCD_2E. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_5DCD_2E_STR,
MANDT TYPE STRING,
ANTYP TYPE STRING,
ANSPR TYPE STRING,
MODBV TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
ATEXT TYPE STRING,
MBVTX TYPE STRING,
LGART TYPE STRING,
LGART_TXT TYPE STRING,
RNTYP TYPE STRING,
RNTYP_TXT TYPE STRING,
RDRNT TYPE STRING,
RDVRT TYPE STRING,
RNART TYPE STRING,
BETMI TYPE STRING,
BETMA TYPE STRING,
MRKRE TYPE STRING,
MRKRU TYPE STRING,
LTRPA TYPE STRING,
VLTRG TYPE STRING,
VLTRG_TXT TYPE STRING,
VLTMA TYPE STRING,
WIGUT TYPE STRING,
RWZKO TYPE STRING,
WZMTH TYPE STRING,
RDWZT TYPE STRING,
WZPVZ TYPE STRING,
WZPPA TYPE STRING,
WZPL2 TYPE STRING,
L2WLB TYPE STRING,
L2WLM TYPE STRING,
UAPVZ TYPE STRING,
UA1KO TYPE STRING,
UA2KO TYPE STRING,
UA3KO TYPE STRING,
UA4KO TYPE STRING,
UAPL2 TYPE STRING,
L2ULB TYPE STRING,
L2ULM TYPE STRING,
L2UMT TYPE STRING,
L2WMT TYPE STRING,
L2UDA TYPE STRING,
L2WDA TYPE STRING,
STUAJ TYPE STRING,
STUAN TYPE STRING,
RELZL TYPE STRING,
ZLTYP TYPE STRING,
MOZAN TYPE STRING,
GRUAN TYPE STRING,
SETRD TYPE STRING,
LIMIT TYPE STRING,
AVERD TYPE STRING,
LIMTX TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_5DCD_2E_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_5DCD_2E_STR-MANDT sy-vline
WA_V_5DCD_2E_STR-ANTYP sy-vline
WA_V_5DCD_2E_STR-ANSPR sy-vline
WA_V_5DCD_2E_STR-MODBV sy-vline
WA_V_5DCD_2E_STR-ENDDA sy-vline
WA_V_5DCD_2E_STR-BEGDA sy-vline
WA_V_5DCD_2E_STR-ATEXT sy-vline
WA_V_5DCD_2E_STR-MBVTX sy-vline
WA_V_5DCD_2E_STR-LGART sy-vline
WA_V_5DCD_2E_STR-LGART_TXT sy-vline
WA_V_5DCD_2E_STR-RNTYP sy-vline
WA_V_5DCD_2E_STR-RNTYP_TXT sy-vline
WA_V_5DCD_2E_STR-RDRNT sy-vline
WA_V_5DCD_2E_STR-RDVRT sy-vline
WA_V_5DCD_2E_STR-RNART sy-vline
WA_V_5DCD_2E_STR-BETMI sy-vline
WA_V_5DCD_2E_STR-BETMA sy-vline
WA_V_5DCD_2E_STR-MRKRE sy-vline
WA_V_5DCD_2E_STR-MRKRU sy-vline
WA_V_5DCD_2E_STR-LTRPA sy-vline
WA_V_5DCD_2E_STR-VLTRG sy-vline
WA_V_5DCD_2E_STR-VLTRG_TXT sy-vline
WA_V_5DCD_2E_STR-VLTMA sy-vline
WA_V_5DCD_2E_STR-WIGUT sy-vline
WA_V_5DCD_2E_STR-RWZKO sy-vline
WA_V_5DCD_2E_STR-WZMTH sy-vline
WA_V_5DCD_2E_STR-RDWZT sy-vline
WA_V_5DCD_2E_STR-WZPVZ sy-vline
WA_V_5DCD_2E_STR-WZPPA sy-vline
WA_V_5DCD_2E_STR-WZPL2 sy-vline
WA_V_5DCD_2E_STR-L2WLB sy-vline
WA_V_5DCD_2E_STR-L2WLM sy-vline
WA_V_5DCD_2E_STR-UAPVZ sy-vline
WA_V_5DCD_2E_STR-UA1KO sy-vline
WA_V_5DCD_2E_STR-UA2KO sy-vline
WA_V_5DCD_2E_STR-UA3KO sy-vline
WA_V_5DCD_2E_STR-UA4KO sy-vline
WA_V_5DCD_2E_STR-UAPL2 sy-vline
WA_V_5DCD_2E_STR-L2ULB sy-vline
WA_V_5DCD_2E_STR-L2ULM sy-vline
WA_V_5DCD_2E_STR-L2UMT sy-vline
WA_V_5DCD_2E_STR-L2WMT sy-vline
WA_V_5DCD_2E_STR-L2UDA sy-vline
WA_V_5DCD_2E_STR-L2WDA sy-vline
WA_V_5DCD_2E_STR-STUAJ sy-vline
WA_V_5DCD_2E_STR-STUAN sy-vline
WA_V_5DCD_2E_STR-RELZL sy-vline
WA_V_5DCD_2E_STR-ZLTYP sy-vline
WA_V_5DCD_2E_STR-MOZAN sy-vline
WA_V_5DCD_2E_STR-GRUAN sy-vline
WA_V_5DCD_2E_STR-SETRD sy-vline
WA_V_5DCD_2E_STR-LIMIT sy-vline
WA_V_5DCD_2E_STR-AVERD sy-vline
WA_V_5DCD_2E_STR-LIMTX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.