ABAP Select data from SAP table V_554S_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V_554S_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V_554S_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V_554S_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V_554S_D TYPE STANDARD TABLE OF V_554S_D,
      WA_V_554S_D TYPE V_554S_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V_554S_D> TYPE V_554S_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V_554S_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V_554S_D
  INTO TABLE IT_V_554S_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V_554S_D
*  INTO TABLE @DATA(IT_V_554S_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V_554S_D INDEX 1 INTO DATA(WA_V_554S_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V_554S_D ASSIGNING <V_554S_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V_554S_D>-MANDT = 1.
<V_554S_D>-MOABW = 1.
<V_554S_D>-SUBTY = 1.
<V_554S_D>-ENDDA = 1.
<V_554S_D>-BEGDA = 1.
ENDLOOP.

LOOP AT IT_V_554S_D INTO WA_V_554S_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V_554S_D-ATEXT, sy-vline,
WA_V_554S_D-PCOPT, sy-vline,
WA_V_554S_D-ABSTP, sy-vline,
WA_V_554S_D-ABSTY, sy-vline,
WA_V_554S_D-ART01, sy-vline,
WA_V_554S_D-D2OBL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V_554S_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V_554S_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V_554S_D INTO WA_V_554S_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V_554S_D_STR,
MANDT TYPE STRING,
MOABW TYPE STRING,
SUBTY TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
ATEXT TYPE STRING,
PCOPT TYPE STRING,
ABSTP TYPE STRING,
ABSTY TYPE STRING,
ART01 TYPE STRING,
D2OBL TYPE STRING,
REABF TYPE STRING,
REAEF TYPE STRING,
REAZF TYPE STRING,
MINTG TYPE STRING,
MAXTG TYPE STRING,
KLZBI TYPE STRING,
KLBEW TYPE STRING,
ABKLA TYPE STRING,
DUEVO TYPE STRING,
DYNNR TYPE STRING,
KTART TYPE STRING,
RGMOD TYPE STRING,
KLBDE TYPE STRING,
KUNBZ TYPE STRING,
ERGAB TYPE STRING,
STKRV TYPE STRING,
STUND TYPE STRING,
URMAN TYPE STRING,
ABWRG TYPE STRING,
VBLAK TYPE STRING,
ABKND TYPE STRING,
CLTIM TYPE STRING,
LVCUT TYPE STRING,
LVMIN TYPE STRING,
LVMAX TYPE STRING,
CRULE TYPE STRING,
DEDQU TYPE STRING,
AVAIL TYPE STRING,
ENDCK TYPE STRING,
ACCNT TYPE STRING,END OF T_EKKO_STR. DATA: WA_V_554S_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V_554S_D_STR-MANDT sy-vline
WA_V_554S_D_STR-MOABW sy-vline
WA_V_554S_D_STR-SUBTY sy-vline
WA_V_554S_D_STR-ENDDA sy-vline
WA_V_554S_D_STR-BEGDA sy-vline
WA_V_554S_D_STR-ATEXT sy-vline
WA_V_554S_D_STR-PCOPT sy-vline
WA_V_554S_D_STR-ABSTP sy-vline
WA_V_554S_D_STR-ABSTY sy-vline
WA_V_554S_D_STR-ART01 sy-vline
WA_V_554S_D_STR-D2OBL sy-vline
WA_V_554S_D_STR-REABF sy-vline
WA_V_554S_D_STR-REAEF sy-vline
WA_V_554S_D_STR-REAZF sy-vline
WA_V_554S_D_STR-MINTG sy-vline
WA_V_554S_D_STR-MAXTG sy-vline
WA_V_554S_D_STR-KLZBI sy-vline
WA_V_554S_D_STR-KLBEW sy-vline
WA_V_554S_D_STR-ABKLA sy-vline
WA_V_554S_D_STR-DUEVO sy-vline
WA_V_554S_D_STR-DYNNR sy-vline
WA_V_554S_D_STR-KTART sy-vline
WA_V_554S_D_STR-RGMOD sy-vline
WA_V_554S_D_STR-KLBDE sy-vline
WA_V_554S_D_STR-KUNBZ sy-vline
WA_V_554S_D_STR-ERGAB sy-vline
WA_V_554S_D_STR-STKRV sy-vline
WA_V_554S_D_STR-STUND sy-vline
WA_V_554S_D_STR-URMAN sy-vline
WA_V_554S_D_STR-ABWRG sy-vline
WA_V_554S_D_STR-VBLAK sy-vline
WA_V_554S_D_STR-ABKND sy-vline
WA_V_554S_D_STR-CLTIM sy-vline
WA_V_554S_D_STR-LVCUT sy-vline
WA_V_554S_D_STR-LVMIN sy-vline
WA_V_554S_D_STR-LVMAX sy-vline
WA_V_554S_D_STR-CRULE sy-vline
WA_V_554S_D_STR-DEDQU sy-vline
WA_V_554S_D_STR-AVAIL sy-vline
WA_V_554S_D_STR-ENDCK sy-vline
WA_V_554S_D_STR-ACCNT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.