ABAP Select data from SAP table V7EHS00_CALDEF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V7EHS00_CALDEF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V7EHS00_CALDEF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V7EHS00_CALDEF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V7EHS00_CALDEF TYPE STANDARD TABLE OF V7EHS00_CALDEF,
      WA_V7EHS00_CALDEF TYPE V7EHS00_CALDEF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V7EHS00_CALDEF> TYPE V7EHS00_CALDEF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V7EHS00_CALDEF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V7EHS00_CALDEF
  INTO TABLE IT_V7EHS00_CALDEF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V7EHS00_CALDEF
*  INTO TABLE @DATA(IT_V7EHS00_CALDEF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V7EHS00_CALDEF INDEX 1 INTO DATA(WA_V7EHS00_CALDEF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V7EHS00_CALDEF ASSIGNING <V7EHS00_CALDEF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V7EHS00_CALDEF>-MANDT = 1.
<V7EHS00_CALDEF>-RECN = 1.
<V7EHS00_CALDEF>-ACTN = 1.
<V7EHS00_CALDEF>-AENNR = 1.
<V7EHS00_CALDEF>-CRNAM = 1.
ENDLOOP.

LOOP AT IT_V7EHS00_CALDEF INTO WA_V7EHS00_CALDEF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V7EHS00_CALDEF-CRDTIMESTAMP, sy-vline,
WA_V7EHS00_CALDEF-UPDNAM, sy-vline,
WA_V7EHS00_CALDEF-UPDTIMESTAMP, sy-vline,
WA_V7EHS00_CALDEF-UNAME, sy-vline,
WA_V7EHS00_CALDEF-OWNER, sy-vline,
WA_V7EHS00_CALDEF-OWNER_NAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V7EHS00_CALDEF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V7EHS00_CALDEF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V7EHS00_CALDEF INTO WA_V7EHS00_CALDEF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V7EHS00_CALDEF-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V7EHS00_CALDEF-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V7EHS00_CALDEF-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V7EHS00_CALDEF-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V7EHS00_CALDEF-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V7EHS00_CALDEF-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_V7EHS00_CALDEF-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V7EHS00_CALDEF-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V7EHS00_CALDEF_STR,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
AENNR TYPE STRING,
CRNAM TYPE STRING,
CRDTIMESTAMP TYPE STRING,
UPDNAM TYPE STRING,
UPDTIMESTAMP TYPE STRING,
UNAME TYPE STRING,
OWNER TYPE STRING,
OWNER_NAME TYPE STRING,
LOGSYS TYPE STRING,
OBJTYPE TYPE STRING,
OBJKEY TYPE STRING,
DEFAULT_FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_V7EHS00_CALDEF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V7EHS00_CALDEF_STR-MANDT sy-vline
WA_V7EHS00_CALDEF_STR-RECN sy-vline
WA_V7EHS00_CALDEF_STR-ACTN sy-vline
WA_V7EHS00_CALDEF_STR-AENNR sy-vline
WA_V7EHS00_CALDEF_STR-CRNAM sy-vline
WA_V7EHS00_CALDEF_STR-CRDTIMESTAMP sy-vline
WA_V7EHS00_CALDEF_STR-UPDNAM sy-vline
WA_V7EHS00_CALDEF_STR-UPDTIMESTAMP sy-vline
WA_V7EHS00_CALDEF_STR-UNAME sy-vline
WA_V7EHS00_CALDEF_STR-OWNER sy-vline
WA_V7EHS00_CALDEF_STR-OWNER_NAME sy-vline
WA_V7EHS00_CALDEF_STR-LOGSYS sy-vline
WA_V7EHS00_CALDEF_STR-OBJTYPE sy-vline
WA_V7EHS00_CALDEF_STR-OBJKEY sy-vline
WA_V7EHS00_CALDEF_STR-DEFAULT_FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.